Robert E. Highland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert E. Highland has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Adam Wax
Department of Biomedical Engineering Duke University Durham North Carolina USA
8 shared publications - David A. Miller
Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
6 shared publications Albert Rancu
Department of Biomedical Engineering, Duke Universityhttps://ror.org/00py81415, Durham, North Carolina 27708, USA
2 shared publicationsBrenton D. Hoffman
Department of Biomedical Engineering, Duke Universityhttps://ror.org/00py81415, Durham, North Carolina 27708, USA
2 shared publications- Erin C. O’KAne
Department of Biomedical Engineering, Duke University, Durham, NC 27707, USA
2 shared publications - Hillel Price
Duke Univ. (United States)
2 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by Elsevier in Blood Red Cells & Iron
- Vol. 2 (4)
Holographic cytometry assesses therapeutic effects in sickle cell disease
- 12 August 2026
- Published by Elsevier in Blood Red Cells & Iron
- Vol. 2 (4)
Open AccessHolographic cytometry assesses therapeutic effects in sickle cell disease
- 3 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3434-3448
Spectroscopic correlation tomography (SpCT) for visualization of spatial correlations in volumetric OCT scans
Spectroscopic optical coherence tomography (SOCT) allows for the targeted analysis of cell nuclei due to their spectrally distinct scattering properties. SOCT has been explored for optical biopsy based on its ability to extract structural and spectroscopic properties of a sample without the need for labels. Using the dual-window method for SOCT, spatial correlations can be computed throughout volumetric scans and analyzed to determine the size of cell nuclei. Such analysis could enable quantitative visualization of tissue boundaries that appear homogenous in structural OCT images. Here, we present spectroscopic correlation tomography (SpCT), a technique for mapping spatial correlation measurements to a hue-saturation-value (HSV) color space to help visualize relative changes in spatial correlation throughout volumetric OCT samples. SpCT B-Scans and volumes of polystyrene bead samples with diameters 5.1 μm to 11.3 μm were acquired and scatterer sizes were quantified using a Gaussian mixture model, achieving size estimates within half-wavelength accuracy. 3T3 fibroblasts were imaged and analyzed via connected component analysis, producing strong agreement with scatterer size measured via confocal microscopy, thus validating our approach. Histology versus SpCT B-Scan comparisons were performed for human colon organoids, cardiac organoids, and human lung airway explant to demonstrate this technique’s ability to identify varying degrees of nuclear morphology in different regions. SpCT volumes were used to objectively discriminate between control and APC -mutated human colon organoids based on a connected component analysis, identifying regions of long spatial correlation and computing the coefficient of variation of the region volumes, which points to a potential clinical use of this technique.
- 3 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3434-3448
Spectroscopic correlation tomography (SpCT) for visualization of spatial correlations in volumetric OCT scans
Spectroscopic optical coherence tomography (SOCT) allows for the targeted analysis of cell nuclei due to their spectrally distinct scattering properties. SOCT has been explored for optical biopsy based on its ability to extract structural and spectroscopic properties of a sample without the need for labels. Using the dual-window method for SOCT, spatial correlations can be computed throughout volumetric scans and analyzed to determine the size of cell nuclei. Such analysis could enable quantitative visualization of tissue boundaries that appear homogenous in structural OCT images. Here, we present spectroscopic correlation tomography (SpCT), a technique for mapping spatial correlation measurements to a hue-saturation-value (HSV) color space to help visualize relative changes in spatial correlation throughout volumetric OCT samples. SpCT B-Scans and volumes of polystyrene bead samples with diameters 5.1 μm to 11.3 μm were acquired and scatterer sizes were quantified using a Gaussian mixture model, achieving size estimates within half-wavelength accuracy. 3T3 fibroblasts were imaged and analyzed via connected component analysis, producing strong agreement with scatterer size measured via confocal microscopy, thus validating our approach. Histology versus SpCT B-Scan comparisons were performed for human colon organoids, cardiac organoids, and human lung airway explant to demonstrate this technique’s ability to identify varying degrees of nuclear morphology in different regions. SpCT volumes were used to objectively discriminate between control and APC -mutated human colon organoids based on a connected component analysis, identifying regions of long spatial correlation and computing the coefficient of variation of the region volumes, which points to a potential clinical use of this technique.
- Open Access
- 21 October 2025
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 3 (01) , 1-14
Real-time processing of high-throughput quantitative phase microscopy data using a Jetson Orin Nano
SignificanceQuantitative phase microscopy (QPM) is a holographic imaging technique often applied to studying cell morphology. To advance QPM for clinical applications, high-throughput implementations have been developed to allow imaging of thousands of cells at a time.AimTo meet the needs of processing raw data and creating QPM holographic images, higher throughput processing methods are needed. Here, we report on the use of a system-on-module approach for QPM data processing.ApproachWe have developed a real-time processing pipeline that leverages the parallel processing capabilities of the NVIDIA Jetson Orin Nano to implement processing of cell data. We demonstrate this pipeline on a holographic cytometry (HC) system, a high-throughput QPM implementation. The CUDA processing algorithm enables the generation of QPM data from raw interferograms followed by phase unwrapping, cell segmentation, and refocusing.ResultWe captured, processed, and analyzed 107,631 red blood cell images. The processing speed reaches 1200 cells/s in the speed test. Benchmarking shows that real-time refocusing maintains a high degree of structural similarity to the traditional refocusing method.ConclusionThe result demonstrates that our pipeline could accelerate the statistical analysis of cell populations. We expect this study to benefit the development of a portable, low-cost HC system.
- 21 October 2025
- Published by SPIE-Intl Soc Optical Eng in Biophotonics Discovery
- Vol. 3 (01) , 1-14
Open AccessReal-time processing of high-throughput quantitative phase microscopy data using a Jetson Orin Nano
SignificanceQuantitative phase microscopy (QPM) is a holographic imaging technique often applied to studying cell morphology. To advance QPM for clinical applications, high-throughput implementations have been developed to allow imaging of thousands of cells at a time.AimTo meet the needs of processing raw data and creating QPM holographic images, higher throughput processing methods are needed. Here, we report on the use of a system-on-module approach for QPM data processing.ApproachWe have developed a real-time processing pipeline that leverages the parallel processing capabilities of the NVIDIA Jetson Orin Nano to implement processing of cell data. We demonstrate this pipeline on a holographic cytometry (HC) system, a high-throughput QPM implementation. The CUDA processing algorithm enables the generation of QPM data from raw interferograms followed by phase unwrapping, cell segmentation, and refocusing.ResultWe captured, processed, and analyzed 107,631 red blood cell images. The processing speed reaches 1200 cells/s in the speed test. Benchmarking shows that real-time refocusing maintains a high degree of structural similarity to the traditional refocusing method.ConclusionThe result demonstrates that our pipeline could accelerate the statistical analysis of cell populations. We expect this study to benefit the development of a portable, low-cost HC system.
- 19 August 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 42 (9) , 1344-1353
Spectroscopic analysis of volumetric OCT data for the automated measurement of scatterer size
Spectroscopic optical coherence tomography enables an accurate estimation of scatterer size by computing the correlation distance (CD) function. For calibration and accuracy verification, polystyrene spheres are commonly used as size standards. However, anomalies have been observed when using the CD function to analyze spherical scatterers, which we link to multiple scattering. We have developed a robust, automated algorithm to calculate the size of hundreds of scatterers within a volumetric OCT image while accounting for the effects of multiple scattering. We measured 5.1, 7.7, and 11.3 µm polystyrene beads suspended in collagen hydrogel, agarose, and polydimethylsiloxane, which resulted in average diameters in agreement with the theoretical size to within ±λ/2, using this analysis approach. Accurately accounting for these multiple scattering effects is crucial for a robust calibration, and these measurements point the way toward analyzing the nuclear size of cells throughout a 3D tissue volume.
- 19 August 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 42 (9) , 1344-1353
Spectroscopic analysis of volumetric OCT data for the automated measurement of scatterer size
Spectroscopic optical coherence tomography enables an accurate estimation of scatterer size by computing the correlation distance (CD) function. For calibration and accuracy verification, polystyrene spheres are commonly used as size standards. However, anomalies have been observed when using the CD function to analyze spherical scatterers, which we link to multiple scattering. We have developed a robust, automated algorithm to calculate the size of hundreds of scatterers within a volumetric OCT image while accounting for the effects of multiple scattering. We measured 5.1, 7.7, and 11.3 µm polystyrene beads suspended in collagen hydrogel, agarose, and polydimethylsiloxane, which resulted in average diameters in agreement with the theoretical size to within ±λ/2, using this analysis approach. Accurately accounting for these multiple scattering effects is crucial for a robust calibration, and these measurements point the way toward analyzing the nuclear size of cells throughout a 3D tissue volume.
- Top Cited Papers
- 8 January 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (1) , 24-30
Enhanced penetration depth in optical coherence tomography and photoacoustic microscopy in vivo enabled by absorbing dye molecules
The scattering and absorption of light within biological tissue severely limits the penetration depth of optical imaging techniques. Recently, it has been found that water-soluble, strongly absorbing dye molecules, such as tartrazine, can achieve in vivo tissue transparency by increasing the refractive index of aqueous components in tissue, as predicted by the Lorentz oscillator model and Kramers–Kronig relations. In this study, we topically applied absorbing dye molecules to the abdominal skin of pigmented and nonpigmented mice to enhance the penetration depth of optical coherence tomography (OCT) and photoacoustic microscopy (PAM). In both types of mice, the penetration depth of OCT was significantly improved using tartrazine and 4-aminoantipyrine. As predicted by the Kramers–Kronig relations and absorption spectra of the dyes, mice treated with 4-aminoantipyrine showed significantly improved penetration depth compared to mice treated with tartrazine for the PAM system with 532 nm excitation. These findings further demonstrate the use of absorbing dye molecules for achieving tissue transparency to enhance the penetration depth of depth-resolved optical imaging modalities in skin, thus accelerating the translation of these technologies in clinical areas, such as dermatology.
- 8 January 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (1) , 24-30
Top Cited PapersEnhanced penetration depth in optical coherence tomography and photoacoustic microscopy in vivo enabled by absorbing dye molecules
The scattering and absorption of light within biological tissue severely limits the penetration depth of optical imaging techniques. Recently, it has been found that water-soluble, strongly absorbing dye molecules, such as tartrazine, can achieve in vivo tissue transparency by increasing the refractive index of aqueous components in tissue, as predicted by the Lorentz oscillator model and Kramers–Kronig relations. In this study, we topically applied absorbing dye molecules to the abdominal skin of pigmented and nonpigmented mice to enhance the penetration depth of optical coherence tomography (OCT) and photoacoustic microscopy (PAM). In both types of mice, the penetration depth of OCT was significantly improved using tartrazine and 4-aminoantipyrine. As predicted by the Kramers–Kronig relations and absorption spectra of the dyes, mice treated with 4-aminoantipyrine showed significantly improved penetration depth compared to mice treated with tartrazine for the PAM system with 532 nm excitation. These findings further demonstrate the use of absorbing dye molecules for achieving tissue transparency to enhance the penetration depth of depth-resolved optical imaging modalities in skin, thus accelerating the translation of these technologies in clinical areas, such as dermatology.
- 12 September 2024
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 41 (11) , C38-C48
Multimodal segmentation of dynamic subcellular features using quantitative phase imaging and FRET-based sensors [Invited]
Understanding cellular responses to mechanical environmental stimuli is important for cellular mechanotransduction studies. While fluorescence microscopy has been used for aiding mechanotransduction research due to its molecular sensitivity, the ability of quantitative phase imaging (QPI) to visualize morphology has yet to be widely applied, perhaps due to its limited specificity. Here, we seek to expand on previous work which combined quantitative phase imaging with a molecularly sensitive Förster resonance energy transfer (FRET) construct by developing additional analysis techniques. This work seeks to characterize the response of individual cells to mechanical stimulus through a novel, to the best of our knowledge, QPI-guided cellular segmentation algorithm. The multimodal imaging instrument and analysis techniques are employed to examine cellular responses to hypo-osmotic stimulus by observing the calcium ion flux using a FRET-based sensor coupled with a mapping of intracellular mass reorganization using QPI. The combined imaging modality enables a discrimination of cell response by localized region, revealing distinct behavior between regions and relative to a control group. Our novel analysis techniques can be used to identify cell expansion and cell region specific responses in both modalities due to the stimulus. With the broad array of FRET sensors under development, the complementary addition of QPI offers new avenues for studying cell responses to a range of environmental stimuli.
- 12 September 2024
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 41 (11) , C38-C48
Multimodal segmentation of dynamic subcellular features using quantitative phase imaging and FRET-based sensors [Invited]
Understanding cellular responses to mechanical environmental stimuli is important for cellular mechanotransduction studies. While fluorescence microscopy has been used for aiding mechanotransduction research due to its molecular sensitivity, the ability of quantitative phase imaging (QPI) to visualize morphology has yet to be widely applied, perhaps due to its limited specificity. Here, we seek to expand on previous work which combined quantitative phase imaging with a molecularly sensitive Förster resonance energy transfer (FRET) construct by developing additional analysis techniques. This work seeks to characterize the response of individual cells to mechanical stimulus through a novel, to the best of our knowledge, QPI-guided cellular segmentation algorithm. The multimodal imaging instrument and analysis techniques are employed to examine cellular responses to hypo-osmotic stimulus by observing the calcium ion flux using a FRET-based sensor coupled with a mapping of intracellular mass reorganization using QPI. The combined imaging modality enables a discrimination of cell response by localized region, revealing distinct behavior between regions and relative to a control group. Our novel analysis techniques can be used to identify cell expansion and cell region specific responses in both modalities due to the stimulus. With the broad array of FRET sensors under development, the complementary addition of QPI offers new avenues for studying cell responses to a range of environmental stimuli.
- 31 July 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (15) , 4457-4460
Utilizing quantitative phase microscopy to localize fluorescence in three dimensions via the transport of intensity equation
We demonstrate the use of a novel, to the best of our knowledge, localization algorithm for digitally refocusing fluorescence images from a three-dimensional cell culture. Simultaneous phase and fluorescence intensity images are collected through a multimodal system that combines digital holography via quantitative phase microscopy (QPM) and fluorescence microscopy. Defocused fluorescence images are localized to a specific z-plane within the three-dimensional (3D) matrix using the transport of intensity equation (TIE) and depth-resolved information derived from the QPM measurements. This technique is applied to cells stained with different fluorescent tags suspended in 3D collagen hydrogel cultures. Experimental findings demonstrate the localization of defocused images, facilitating the analysis and comparison of cells within the hydrogel matrix. This method holds promise for comprehensive cellular imaging of fluorescence labeling in three-dimensional environments, enabling detailed investigations into cellular behavior and interactions.
- 31 July 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (15) , 4457-4460
Utilizing quantitative phase microscopy to localize fluorescence in three dimensions via the transport of intensity equation
We demonstrate the use of a novel, to the best of our knowledge, localization algorithm for digitally refocusing fluorescence images from a three-dimensional cell culture. Simultaneous phase and fluorescence intensity images are collected through a multimodal system that combines digital holography via quantitative phase microscopy (QPM) and fluorescence microscopy. Defocused fluorescence images are localized to a specific z-plane within the three-dimensional (3D) matrix using the transport of intensity equation (TIE) and depth-resolved information derived from the QPM measurements. This technique is applied to cells stained with different fluorescent tags suspended in 3D collagen hydrogel cultures. Experimental findings demonstrate the localization of defocused images, facilitating the analysis and comparison of cells within the hydrogel matrix. This method holds promise for comprehensive cellular imaging of fluorescence labeling in three-dimensional environments, enabling detailed investigations into cellular behavior and interactions.
- Open Access
Analysis of intracellular transport dynamics using quantitative phase imaging and FRET-based calcium sensors
Understanding cellular responses to mechanical environmental stimuli is an essential goal of cellular mechanotransduction studies and remains a target for microscopy technique development. While fluorescence microscopy has been advanced for this purpose - its molecular sensitivity, the ability of quantitative phase imaging to visualize subcellular structure has yet to be widely applied, perhaps due to its limited specificity. Here we seek to combine Quantitative Phase Imaging (QPI) with a molecularly sensitive Förster resonance energy transfer (FRET) construct for cell mechanotransduction studies. The multimodal imaging instrument is applied to examine cellular response to hypo-osmotic stimulus by observing the influx of calcium ions using a FRET based sensor coupled with mapping of the redistribution of intracellular mass using QPI. The combined imaging modality enables discrimination of cell response by localized region and reveals distinct behavior for each. The analysis shows cell flattening and oscillatory mass transport in response to the stimulus. With the broad array of FRET sensors under development, the combination with QPI offers new avenues for studying cell response to environmental stimuli.
Open AccessAnalysis of intracellular transport dynamics using quantitative phase imaging and FRET-based calcium sensors
Understanding cellular responses to mechanical environmental stimuli is an essential goal of cellular mechanotransduction studies and remains a target for microscopy technique development. While fluorescence microscopy has been advanced for this purpose - its molecular sensitivity, the ability of quantitative phase imaging to visualize subcellular structure has yet to be widely applied, perhaps due to its limited specificity. Here we seek to combine Quantitative Phase Imaging (QPI) with a molecularly sensitive Förster resonance energy transfer (FRET) construct for cell mechanotransduction studies. The multimodal imaging instrument is applied to examine cellular response to hypo-osmotic stimulus by observing the influx of calcium ions using a FRET based sensor coupled with mapping of the redistribution of intracellular mass using QPI. The combined imaging modality enables discrimination of cell response by localized region and reveals distinct behavior for each. The analysis shows cell flattening and oscillatory mass transport in response to the stimulus. With the broad array of FRET sensors under development, the combination with QPI offers new avenues for studying cell response to environmental stimuli.