Veronika Sedláková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Veronika Sedláková has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Norbert Ferenčík
Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, 042 00 Košice, Slovakia
2 shared publications - Radovan Hudák
Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Kosice, Letná 1/9, 042 00 Košice, Slovakia
2 shared publications - Branko Štefanovič
Department of Biomedical Engineering and Measurement, Faculty of Mechanical Engineering, Technical University of Košice, Letná 1/9, 04200 Košice, Slovakia
1 shared publication Dominik Hakulin
Datacomp s.r.o Moldavská cesta 32 040 11 Košice Slovakia
1 shared publication- Marianna Ondrášová
Faculty of Mechanical Engineering, Technical University of Košice, Letná 9, 042 00 Košice, Slovakia
1 shared publication Peter Kneppo
Department of Biomedical Engineering Czech Technical University in Prague Czech republic
1 shared publication
Latest Publications
- Open Access
- 31 October 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (11) , 1291
Design and Validation of a 3D-Printed Low-Frequency Mechanical Stimulation Device for In Vitro Applications
This study describes the development, technical validation, and preliminary biological evaluation of a custom-built, low-cost device designed to apply low-amplitude mechanical vibrations to cultured cells. The system consists of 3D-printed PLA components and a miniature loudspeaker (8 Ω, 0.5 W) driven by a pulse-width modulation (PWM) module. The electrical excitation signal was verified using digital oscilloscopy and Fast Fourier Transform (FFT) analysis, which confirmed a stable fundamental frequency of 30 Hz within the mechanically effective operating range of the actuator (approximately 20–90 Hz); higher harmonic components at integer multiples of the fundamental frequency (60–180 Hz), characteristic of rectangular PWM excitation, were also detected. At the stimulation setting (30 Hz, 30% duty cycle), a MEMS accelerometer at the culture position recorded a resultant acceleration of 1.04–1.10 g (vibration-related component of approximately 0.04–0.10 g). Human gingival fibroblasts (GF06) cultured in 35 mm Petri dishes were exposed to daily vibration outside a CO2 incubator, and their response was evaluated using the MTT assay and an in vitro wound healing (scratch) assay. After 24 h of daily 15 min stimulation, the metabolic activity of vibration-treated cultures exceeded that of the controls by approximately 15 and 25 percentage points at the lower and higher seeding densities, respectively; however, these differences were not statistically significant (p = 0.189 and p = 0.098). When the daily stimulation duration was varied, the MTT signal after 72 h increased with the stimulation duration, reaching approximately 115%, 134%, and 154% of the control for 150, 300, and 450 s, respectively (p < 0.05 for 300 and 450 s). In the scratch assay, stimulation for 450 s increased gap closure compared with the control after 6 h (35.4% vs. 3.4%) and 24 h (53.4% vs. 21.2%; p < 0.01). No evident cytotoxic effects were observed under the tested conditions. The study demonstrates the technical feasibility of the platform and its ability to elicit a measurable, stimulation duration-dependent biological response, and it provides a basis for future experiments that include direct mechanical characterization of the stimulus and larger numbers of independent biological replicates under controlled physiological conditions.
- 31 October 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (11) , 1291
Open AccessDesign and Validation of a 3D-Printed Low-Frequency Mechanical Stimulation Device for In Vitro Applications
This study describes the development, technical validation, and preliminary biological evaluation of a custom-built, low-cost device designed to apply low-amplitude mechanical vibrations to cultured cells. The system consists of 3D-printed PLA components and a miniature loudspeaker (8 Ω, 0.5 W) driven by a pulse-width modulation (PWM) module. The electrical excitation signal was verified using digital oscilloscopy and Fast Fourier Transform (FFT) analysis, which confirmed a stable fundamental frequency of 30 Hz within the mechanically effective operating range of the actuator (approximately 20–90 Hz); higher harmonic components at integer multiples of the fundamental frequency (60–180 Hz), characteristic of rectangular PWM excitation, were also detected. At the stimulation setting (30 Hz, 30% duty cycle), a MEMS accelerometer at the culture position recorded a resultant acceleration of 1.04–1.10 g (vibration-related component of approximately 0.04–0.10 g). Human gingival fibroblasts (GF06) cultured in 35 mm Petri dishes were exposed to daily vibration outside a CO2 incubator, and their response was evaluated using the MTT assay and an in vitro wound healing (scratch) assay. After 24 h of daily 15 min stimulation, the metabolic activity of vibration-treated cultures exceeded that of the controls by approximately 15 and 25 percentage points at the lower and higher seeding densities, respectively; however, these differences were not statistically significant (p = 0.189 and p = 0.098). When the daily stimulation duration was varied, the MTT signal after 72 h increased with the stimulation duration, reaching approximately 115%, 134%, and 154% of the control for 150, 300, and 450 s, respectively (p < 0.05 for 300 and 450 s). In the scratch assay, stimulation for 450 s increased gap closure compared with the control after 6 h (35.4% vs. 3.4%) and 24 h (53.4% vs. 21.2%; p < 0.01). No evident cytotoxic effects were observed under the tested conditions. The study demonstrates the technical feasibility of the platform and its ability to elicit a measurable, stimulation duration-dependent biological response, and it provides a basis for future experiments that include direct mechanical characterization of the stimulus and larger numbers of independent biological replicates under controlled physiological conditions.
- Open Access
- 30 March 2025
- Published by Technical University of Kosice, Faculty of Mechanical Engineering in Acta Mechanica Slovaca
- Vol. 29 (1) , 36-43
Influence of Environmental Factors on Sleep Quality: Analyzing Light Exposure and Sleep Duration with Smartwatch Data
Artificial lighting significantly influences circadian rhythms and sleep quality. This case study investigates the impact of environmental factors including temperature, relative humidity, CO₂ concentration, total volatile organic compo...
- 30 March 2025
- Published by Technical University of Kosice, Faculty of Mechanical Engineering in Acta Mechanica Slovaca
- Vol. 29 (1) , 36-43
Open AccessInfluence of Environmental Factors on Sleep Quality: Analyzing Light Exposure and Sleep Duration with Smartwatch Data
Artificial lighting significantly influences circadian rhythms and sleep quality. This case study investigates the impact of environmental factors including temperature, relative humidity, CO₂ concentration, total volatile organic compo...
- 1 July 2024
- Published by IPSI doo, Belgrade in IPSI Transactions on Internet Research
- Vol. 20 (2) , 107-112
Innovative Solutions for Tetraplegia: A Smart Hand Orthosis Design
Spinal cord injury (SCI) poses a significant medical challenge, affecting both hand dexterity and locomotor abilities. Ongoing advancements in medical technologies, spanning a spectrum of wearable devices, coupled with concurrent progress in rehabilitation treatments, aim to enhance hand function among individuals affected by SCI. The emergence of three-dimensional (3D) printing provides a cost-effective avenue for crafting personalized devices, fostering a surge of interest in integrating this technology with rehabilitation equipment, thereby complementing advancements in scientific research. Myoelectric control plays a pivotal role in achieving enhanced rehabilitation outcomes. It involves the detection and processing of weak electromyographic signals (EMG) from affected limb muscles to activate orthotic motors. A novel 3D-printed hand orthosis, responsive to electromyography signals, has been developed to facilitate grasping functionality in cervical SCI patients.
- 1 July 2024
- Published by IPSI doo, Belgrade in IPSI Transactions on Internet Research
- Vol. 20 (2) , 107-112
Innovative Solutions for Tetraplegia: A Smart Hand Orthosis Design
Spinal cord injury (SCI) poses a significant medical challenge, affecting both hand dexterity and locomotor abilities. Ongoing advancements in medical technologies, spanning a spectrum of wearable devices, coupled with concurrent progress in rehabilitation treatments, aim to enhance hand function among individuals affected by SCI. The emergence of three-dimensional (3D) printing provides a cost-effective avenue for crafting personalized devices, fostering a surge of interest in integrating this technology with rehabilitation equipment, thereby complementing advancements in scientific research. Myoelectric control plays a pivotal role in achieving enhanced rehabilitation outcomes. It involves the detection and processing of weak electromyographic signals (EMG) from affected limb muscles to activate orthotic motors. A novel 3D-printed hand orthosis, responsive to electromyography signals, has been developed to facilitate grasping functionality in cervical SCI patients.