SSSigridur Sigurdardottir

Sigridur Sigurdardottir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sigridur Sigurdardottir has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    World of ScoreCraft : Novel Multi‐Scorer Experiment on the Impact of a Decision Support System in Sleep Staging

    by Benedikt Holm, Arnar Óskarsson, Björn Elvar Þorleifsson, Hörður Þór Hafsteinsson, Sigríður Sigurðardóttir, Heiður Grétarsdóttir, Kenan Hoelke, Gabriel Marc Marie Jouan, Thomas Penzel, Erna Sif Arnardottir, et al.

    Manual scoring of polysomnography (PSG) is a time‐intensive task, prone to inter‐scorer variability that can impact diagnostic reliability. This study investigates the integration of decision support systems (DSS) into PSG scoring workflows, focusing on their effects on accuracy, scoring time and potential biases toward recommendations from artificial intelligence (AI) compared to human‐generated recommendations. Using a novel online scoring platform, we conducted a repeated‐measures study with sleep technologists, who scored traditional and self‐applied PSGs. Participants were occasionally presented with recommendations labelled as either human‐ or AI‐generated. As the goal of this study was to isolate the effect of perceived recommendation sources on scorer behaviour, all recommendations were human‐generated. We found that traditional PSGs tended to be scored slightly more accurately than self‐applied PSGs, but this difference was not statistically significant. Correct recommendations significantly improved scoring accuracy for both PSG types, while incorrect recommendations reduced accuracy. No significant bias was observed toward or against AI‐generated recommendations compared to human‐generated recommendations. These findings highlight the potential of DSSs to enhance PSG scoring reliability. However, ensuring the accuracy of the suggestions is critical to maximising its benefits. Future research should explore the long‐term impacts of DSS on scoring workflows and strategies for integrating AI in clinical practice.

  • Open Access

    Validation of manually scored multichannel frontal electroencephalography against polysomnography in a paediatric cohort

    by Sigridur Sigurdardottir, Henna Pitkänen, Henri Korkalainen, Samu Kainulainen, Marta Serwatko, Kristin A. Olafsdottir, Sigurveig Þ. Sigurðardóttir, Michael Clausen, Pranavan Somaskandhan, Barbara G. Stražišar, et al.

    Summary: Polysomnography is the only internationally recognized method to diagnose paediatric obstructive sleep apnea, thus, simpler and more cost‐effective diagnostic tools are urgently needed. This study aimed to validate the manual scoring of frontal self‐applicable electroencephalography against polysomnography in a paediatric cohort. The polysomnography and the frontal electroencephalography were simultaneously recorded for 1 night ( n = 102) in 10–13‐year‐old children. Scoring was performed according to the American Academy of Sleep Medicine rules, with minor adjustments to the frontal electroencephalography. Manual scorings of sleep stages were compared in an epoch‐by‐epoch manner using Cohen's kappa (κ) and confusion matrices using three different models: the three‐stage (wake/non‐rapid eye movement/rapid eye movement), the four‐stage (wake/sleep stage 1 + sleep stage 2/deep sleep Stage 3/rapid eye movement) and the five‐stage model (wake/sleep stage 1/sleep stage 2/deep sleep Stage 3/rapid eye movement). The inter‐scorer agreements were assessed, and the intraclass correlation coefficient was used for common sleep variables: total sleep time, wake after sleep onset, sleep efficiency, sleep‐onset latency and arousal index. Cohen's κ values for the three‐stage, four‐stage and five‐stage models were 0.85, 0.73 and 0.70, respectively. The agreement for the sleep variables studied ranged from 0.87 to 0.99. The inter‐rater agreement ( n = 10) was κ = 0.78 for the polysomnography and κ = 0.70 for the frontal electroencephalography. Sleep staging from the frontal electroencephalography was comparable to that of a standard polysomnography in a paediatric cohort, and showed promising results in estimating sleep time and sleep architecture.


  • Open Access

    Temporal and sleep stage‐dependent agreement in manual scoring of respiratory events

    by Minna Pitkänen, Henna Pitkänen, Rajdeep Kumar Nath, Sami Nikkonen, Samu Kainulainen, Henri Korkalainen, Kristín Anna Ólafsdóttir, Erna Sif Arnardottir, Sigridur Sigurdardottir, Thomas Penzel, et al.

    Summary: Obstructive sleep apnea diagnosis is based on the manual scoring of respiratory events. The agreement in the manual scoring of the respiratory events lacks an in‐depth investigation as most of the previous studies reported only the apnea–hypopnea index or overall agreement, and not temporal, second‐by‐second or event subtype agreement. We hypothesized the temporal and subtype agreement to be low because the event duration or subtypes are not generally considered in current clinical practice. The data comprised 50 polysomnography recordings scored by 10 experts. The respiratory event agreement between the scorers was calculated using kappa statistics in a second‐by‐second manner. Obstructive sleep apnea severity categories (no obstructive sleep apnea/mild/moderate/severe) were compared between scorers. The Fleiss' kappa value for binary (event/no event) respiratory event scorings was 0.32. When calculated separately within N1, N2, N3 and R, the Fleiss' kappa values were 0.12, 0.23, 0.22 and 0.23, respectively. Binary analysis conducted separately for the event subtypes showed the highest Fleiss' kappa for hypopneas to be 0.26. In 34% of the participants, the obstructive sleep apnea severity category was the same regardless of the scorer, whereas in the rest of the participants the category changed depending on the scorer. Our findings indicate that the agreement of manual scoring of respiratory events depends on the event type and sleep stage. The manual scoring has discrepancies, and these differences affect the obstructive sleep apnea diagnosis. This is an alarming finding, as ultimately these differences in the scorings affect treatment decisions.


  • Open Access

    Retrospective validation of automatic sleep analysis with grey areas model for human‐in‐the‐loop scoring approach

    by Matias Rusanen, Gabriel Jouan, Riku Huttunen, Sami Nikkonen, Sigríður Sigurðardóttir, Juha Töyräs, Brett Duce, Sami Myllymaa, Erna Sif Arnardottir, Timo Leppänen, et al.

    Summary: State‐of‐the‐art automatic sleep staging methods have demonstrated comparable reliability and superior time efficiency to manual sleep staging. However, fully automatic black‐box solutions are difficult to adapt into clinical workflow due to the lack of transparency in decision‐making processes. Transparency would be crucial for interaction between automatic methods and the work of sleep experts, i.e., in human‐in‐the‐loop applications. To address these challenges, we propose an automatic sleep staging model (aSAGA) that effectively utilises both electroencephalography and electro‐oculography channels while incorporating transparency of uncertainty in the decision‐making process. We validated the model through extensive retrospective testing using a range of datasets, including open‐access, clinical, and research‐driven sources. Our channel‐wise ensemble model, trained on both electroencephalography and electro‐oculography signals, demonstrated robustness and the ability to generalise across various types of sleep recordings, including novel self‐applied home polysomnography. Additionally, we compared model uncertainty with human uncertainty in sleep staging and studied various uncertainty mapping metrics to identify ambiguous regions, or “grey areas”, that may require manual re‐evaluation. The validation of this grey area concept revealed its potential to enhance sleep staging accuracy and to highlight regions in the recordings where sleep experts may struggle to reach a consensus. In conclusion, this study provides a technical basis and understanding of automatic sleep staging uncertainty. Our approach has the potential to improve the integration of automatic sleep staging into clinical practice; however, further studies are needed to test the model prospectively in real‐world clinical settings and human‐in‐the‐loop scoring applications.


  • Open Access

    Feasibility and usability of three consecutive nights with self‐applied, home polysomnography

    by Dimitri Ferretti, Anna S. Islind, Kristín A. Ólafsdóttir, Sigridur Sigurdardottir, Kamilla R. Jóhannsdóttir, Jan Hedner, Ludger Grote, Erna Sif Arnardottir

    Summary: In‐laboratory polysomnography, the gold‐standard for diagnosing sleep disorders, is resource‐demanding and not conducive to multiple night evaluations. Ambulatory polysomnography, especially when self‐applied, could be a viable alternative. This study aimed to assess the feasibility and reliability of self‐applied polysomnography over three consecutive nights in untrained participants, assessing: technical success rate; comparing sleep diagnostic variables from single and multiple nights; and evaluating participants' subjective experience. Data were collected from 78 participants (55.1% females) invited to test a self‐applicable polysomnography device for three consecutive nights at home. The technical success rate for valid sleep recordings was 82.5% out of 234 planned study nights, with 87.2% of participants obtaining at least two valid nights. Misclassification of obstructive sleep apnea severity was higher in participants with mild OSA (21.4%) compared with those with moderate‐to‐severe obstructive sleep apnea or no obstructive sleep apnea. Sleep efficiency and wake after sleep onset showed improvement from Night 1 to Night 3 (p < 0.001), and the mean polysomnography set‐up time decreased significantly over this period. Participants reported moderate‐to‐high satisfaction with the device (System Usability Scale score 71.2 ± 12.4). The findings suggest that self‐applied polysomnography is a feasible diagnostic method for untrained individuals at risk for sleep disorders, and that multiple night assessments can improve diagnostic precision for mild obstructive sleep apnea cases.


  • Open Access

    Anomaly detection in sleep: detecting mouth breathing in children

    by Luka Biedebach, María Óskarsdóttir, Erna Sif Arnardóttir, Sigridur Sigurdardóttir, Michael Valur Clausen, Sigurveig Þ. Sigurdardóttir, Marta Serwatko, Anna Sigridur Islind

    Identifying mouth breathing during sleep in a reliable, non-invasive way is challenging and currently not included in sleep studies. However, it has a high clinical relevance in pediatrics, as it can negatively impact the physical and mental health of children. Since mouth breathing is an anomalous condition in the general population with only 2% prevalence in our data set, we are facing an anomaly detection problem. This type of human medical data is commonly approached with deep learning methods. However, applying multiple supervised and unsupervised machine learning methods to this anomaly detection problem showed that classic machine learning methods should also be taken into account. This paper compared deep learning and classic machine learning methods on respiratory data during sleep using a leave-one-out cross validation. This way we observed the uncertainty of the models and their performance across participants with varying signal quality and prevalence of mouth breathing. The main contribution is identifying the model with the highest clinical relevance to facilitate the diagnosis of chronic mouth breathing, which may allow more affected children to receive appropriate treatment.