RARaudel Avila

Raudel Avila

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Raudel Avila has a total of 175 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High‐Modulus Skeleton‐Reinforced PDMS Microstamps for Precision Transfer Printing of Microscale Devices

    by Seol Ahn, Yulin Zhou, Jeongmin Seo, Seong Woo Hong, Sungyeon Kim, Seohyeon Kim, Haechang Ryu, Raudel Avila, Yei Hwan Jung

    Deterministic assembly of microscale devices enables heterogeneous integration in advanced electronic, optoelectronic, and display systems. These applications require precise placement of components such as micro‐light‐emitting diodes (micro‐LEDs), thin‐film transistors, and sensors onto rigid or flexible receiving substrates. Transfer printing provides a scalable route for this alignment‐sensitive assembly, but lateral and rotational misalignment during manufacturing remain important limitations. Conventional elastomeric stamps based on poly(dimethylsiloxane) (PDMS) deform under contact loading, particularly in micropillar configurations, where pillar bending produces positional error and reduces transfer fidelity. Here, we introduce a skeleton‐reinforced hybrid PDMS micropillar stamp that suppresses deformation while retaining the compliant interface required for reliable pick‐up and release. Each pillar contains an embedded high‐modulus PDMS skeleton surrounded by soft PDMS at the periphery and contact surface. The internal skeleton constrains pillar deformation, while the compliant outer layer preserves conformal contact and interfacial adhesion. This architecture improves dimensional stability during compression and reduces sliding of supported microscale devices on receiving substrates. The hybrid stamp therefore provides a scalable strategy for precision transfer printing in high‐resolution displays, flexible electronic systems, and heterogeneous microsystems.

  • Open Access

    Continuous and Wireless Monitoring of Myocardial Dynamics Using Biocompatible Magneto‐Viscoelastic Patches

    by Sunjin Lee, Sumin Kim, Jeongmin Yoo, Ji Hoo Kim, Eun Saem Kang, Eojin Lee, Seung Min Yu, Ji‐Hoon Kim, Siyeon An, Dong‐Soo Han, et al.

    We report a machine learning (ML)‐augmented magnetic sensing system for real‐time, wireless monitoring of cardiac kinematics during recovery following surgery. While conventional monitoring focuses on electrical activity, it overlooks mechanical performance and pumping efficiency. To bridge this diagnostic gap, we developed a biocompatible magnetic particle matrix (MPM) patch incorporating biocompatible ferromagnetic α″‐Fe 16 N 2 microparticles. By integrating this patch onto the epicardium during surgery, our platform enables passive magnetic readout and analysis of epicardial motion without implanted electronics. The system utilizes an external magnetometer to sense 3D magnetic field vectors generated during cardiac contraction and relaxation. By employing a ML‐based regression model, we translate dynamic magnetic field variations into precise 3D spatial coordinates to reconstruct the heart's motion. Beyond positional tracking, this framework enables extraction of clinical‐grade myocardial velocity profiles, delivering real‐time assessment of cardiac health. In vivo studies in rodent models demonstrate the patch resolves cardiac mechanical motion and quantifies acute diastolic dysfunction, revealing pathological shifts undetected by surface ECG. Furthermore, the absence of adverse tissue responses and negligible systemic toxicity after 12 weeks of implantation underscores the biocompatibility of the magnetic particles. These findings establish a foundation for untethered monitoring of cardiac kinematics and suggest an approach for tracking internal organs.

  • Local control of Cre-regulated genetic modeling in vivo using wireless implantable optoelectronics

    by Trisha Bansal, Min-Kyu Lee, Courtney Coleman, Young-Mee Kim, Dane Hintermueller, Yaner Chen, Varsha Sreekanth, Chad R. Haney, Olga A. Karginova, Raudel Avila, et al.

    Effective modeling of chronic human diseases in vivo requires precise spatiotemporal regulation of molecular processes at defined tissue locations. Optogenetic and optoelectronic tools can provide such control but targeting internal organs such as the lungs remain challenging. To address this, we developed E-LightR-Cre recombinase, enabling precise, spatially restricted gene activation with no dark-state activity and robust blue light responsiveness. To achieve local activation of E-LightR-Cre in specific organ sites, we engineered wireless, fully implantable optoelectronic devices enabling focal illumination of murine lungs with no discernible organ damage. The size of the activated area is controlled by modulating light intensity and duration. Using implanted optoelectronic devices, we activated E-LightR-Cre in a selected area of mouse lungs and achieved local regulation of targeted genes. Light-regulated expression of the oncogenic KRas-G12D mutant in mouse lungs induced local formation of oncogenic lesions. These results show that our protein engineering and adaptable optoelectronic approaches enable facile application of optogenetic tools for locally controlled disease modeling in vivo.

  • Conformal mechanics of serpentine meshes for millimeter-scale neural probes

    by Sagidolla Batay, Yulin Zhou, Priyan V. Pathirana, John P. Seymour, Raudel Avila

  • Mechanics of esophageal retraction during anterior cervical discectomy and fusion

    by Chihtong Lee, Alex R. Flores, Mert Çulcu, Alexander E. Ropper, Raudel Avila

  • Open Access

    Safe, high-performance, moisture-activated batteries for powering next-generation Internet-of-Things devices

    by Rajaram Kaveti, Akshay Bhardwaj, Pei Liu, Ayemeh Bagheri Hashkavayi, Bhavya Jain, Adrian Rodriguez-Kattan, Mahaboobbatcha Aleem, Baha Erim Uzunoğlu, Gurudatt N. G., Bünyamin Şahin, et al.

    Conventional batteries are heavy, nonconformal, and toxic, while energy harvesters offer low/variable power, rendering them unsuitable for emerging wearable, robotic, and other Internet-of-Things (IoT) devices. Here, we introduce a nontoxic, thin-film battery superior to several commercial batteries inspired by advances in water harvesting techniques. It scavenges ambient moisture to serve as its electrolyte, combining features of an energy harvester with attractive features of a battery (stable and high power). It functions in a wide range of environments and offers an open-circuit voltage of ~1.6 volts, specific capacity of ~52 milliampere-hours per gram, and specific energy of ~81 milliwatt-hours per gram. Unique pangolin skin–mimicking design imparts high flexibility, stretchability, and fill factor to the battery, ensuring conformability without compromising on capacity. Experimental and computer simulation studies reveal the distinctive materials and design features responsible for the battery’s impressive performance. Examples of a wireless wearable pulse oximeter and surveillance monitor with a unique kill switch that secures it from unauthorized access demonstrate the versatility of the battery to power various IoT devices.


  • Open Access

    Magnetically levitated metasurface enabling tangible and bidirectional human-machine interaction

    by Gooyoon Chung, Jeongmin Yoo, Pei Liu, Gyuri Shin, Dongkyu Jeong, Sunjin Lee, Jae-Young Yoo, Sang Min Won, Dong-Soo Han, Ji-Hoon Kim, et al.

    Mechanical metasurfaces are deformable surfaces that reconfigure their shape in response to external stimuli, with growing applications in interactive displays and human-machine interfaces. However, many existing systems are either too fragile for physical interaction or too slow to match human response. Moreover, their incompatibility for integrating functional systems constrains seamless interaction with humans. We developed a robust, rapidly responsive, and multifunctional soft metasurface capable of intuitive interaction with humans. The soft surface reconfigures through magnetic actuation, enabling mechanical metasurface functions with simultaneous visual and tactile feedback for human interaction. The system features a six-by-six array of elastomeric pixels, each actuated by attractive or repulsive magnetic forces from an underlying electromagnet array. The induced magnetic force modulates the surface height up to 8.5 millimeters (−5 to 3.5 millimeters), enabling coordinated actuation of 36 electromagnets to reconstruct over 10 30 discrete surface morphologies. Its mechanics compliant design allows human interaction such as pushing, pulling, and pinching. Embedded inertial measurement unit sensors reconstruct surface shape in real time, and an integrated light-emitting diode array provides immediate visual feedback. This platform enables fast, reversible, and intuitive interaction between users and programmable surfaces, laying the groundwork for next-generation human-machine interaction systems.

  • Open Access

    Physical Anchoring‐Assisted Mechanically Guided Assembly for Material‐Independent 3D Mesostructures

    by Yeonhee Heo, Pei Liu, Jeongmin Yoo, Jae Hyuk Hwang, Gooyoon Chung, Dong‐Gyun Kim, Raudel Avila, Yoonseok Park

    Mechanically guided 3D assembly has emerged as a powerful approach for constructing complex mesostructures, but conventional strategies rely on selective chemical bonding between 2D precursors and elastomeric substrates, restricting material compatibility and scalability. Here, we introduce a physical anchoring‐based, buckling‐guided assembly platform that decouples 3D structure formation from chemical adhesion. The platform employs an elastomeric substrate patterned with an array of rods to achieve robust mechanical fixation, enabling the integration of diverse functional materials, including polymers, metals, water‐soluble polymers, and stimuli‐responsive systems, independent of their interfacial or mechanical properties. Oxygen plasma surface treatment further reduces adhesion, allowing reliable assembly of freestanding and large‐area architectures. As a proof‐of‐concept, we integrate liquid crystalline networks (LCNs) to demonstrate light‐responsive soft robotic systems capable of remote actuation. This physically anchored assembly strategy establishes a general and scalable framework for mesoscale fabrication, expanding material and geometric design freedom for applications in soft robotics, bioelectronics, and multi‐material integration.

  • Open Access

    Convergent evolution of parrotfish beaks enables stress redistribution during high-force feeding

    by Ritika Raj Menghani, Sean Anthony Trainor, Kory M. Evans, Raudel Avila

    Convergent evolution is often interpreted as evidence that similar ecological challenges select for optimal functional solutions, yet the biomechanical mechanisms underlying such convergence remain poorly resolved. Parrotfishes independently evolved fused, beak-like dentition multiple times, a trait associated with feeding on hard substrates such as coral, but its advantage has not been quantified. Here, we combine finite element analysis with shockwave modeling to evaluate the performance of the beak during feeding. Across five species spanning independent evolutionary origins of beaked and non-beaked dentitions, we find that jaw opening is governed primarily by geometric scaling, with minimal influence from dentition morphology. In contrast, under stabilized biting, fused dentition reduces the rate of stress accumulation relative to discrete teeth, indicating a functional advantage under constrained loading. Shockwave modeling further shows that tooth geometry and stacking regulate stress propagation: smooth profiles reduce stress concentration, while stacked architectures localize stresses within the tooth material and limit transmission into the surrounding bone. These results suggest that convergent beak evolution in parrotfish reflects repeated optimization for stress management under constrained and impact loading, and reveals a general principle by which biological structures control internal force transmission during high-force feeding rather than maximize strength alone.

  • Open Access

    Mechanics of Esophageal Retraction During Anterior Cervical Discectomy and Fusion

    by Chihtong Lee, Alex R Flores, Mert Culcu, Alexander E Ropper, Raudel Avila

    Dysphagia, difficulty swallowing due to irritation or damage to the esophagus, is one of the most common complications following anterior cervical discectomy and fusion (ACDF), the most frequently performed cervical spine procedure in the United States. Surgical retraction hardware imposes sustained compression on the esophagus during surgery, generating nonuniform stress and strain fields that may contribute to temporary postoperative soft tissue damage. Current intraoperative assessment relies on visual inspection and manual inspection by the surgical team and does not provide quantitative measures of esophageal deformation, strain, or retraction displacement. Here, we present a comprehensive mechanics analysis of esophageal compression during ACDF that integrates experiments on esophageal phantoms, nonlinear finite element modeling, and theoretical thick-wall scaling relationships. Modeling results quantify peak contact pressures and corresponding stress distributions, identifying conditions under which circumferential strain in the compressed esophageal wall increases sharply as localized pressures approach the upper physiological range (~6-17 kPa). Parametric investigation of retractor blade width, placement depth, and polymeric biocompatible coating properties demonstrates that targeted, yet mechanically simple, design modifications can help to attenuate strain concentrations. In particular, the introduction of compliant polymeric coatings redistributes contact loads and reduces peak wall stress by up to 20% relative to unbuffered blades (17 kPa to 13.5 kPa). Increasing blade width from 20 mm to 50 mm further decreases peak interface stress from 2.48 kPa to 0.45 kPa, corresponding to an 82% reduction. Reducing these stresses may help limit mechanically induced complications such as postoperative dysphagia. Experiments performed on esophageal phantoms with embedded pressure sensors replicate surgical ACDF retraction protocols under displacement-controlled conditions. This setup establishes physiologically relevant loading and enables quantitative validation of computational predictions by correlating measured voltage output with contact pressure and esophageal deformation. Measured relationships between applied retraction displacement, contact pressure, and tissue deformation govern stress amplification during ACDF retraction. Together, these results establish a predictive mechanics framework that links retractor blade design variables to esophageal stress fields, providing quantitative criteria to mitigate soft tissue damage during ACDF.