FGFanxin Gan

Fanxin Gan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fanxin Gan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Applicability Evaluation of Wind Farm Impedance Models Using Different Aggregation Methods for High Frequency Oscillation Analysis

    by Chunyi Guo, Fanxin Gan, Dongye Du, Yunfei Guo, Hao Cheng

    The aggregated impedance model is widely used for the study of high frequency oscillations (HFOs) in wind farms (WFs). However, the application premise of the aggregated impedance models using different approaches to cluster the whole WF into multiple groups and different approaches to aggregate wind turbines (WTs) and collector lines in the same group is unclear, which needs comprehensive investigation. In this paper, based on a practical doubly-fed WF, the detailed impedance model and the aggregated impedance models using different aggregation methods in the high frequency range are developed. Furthermore, the relative error of the oscillation frequency and the root mean square error (RMSE) of the phase in wide frequency range of impedance model are adopted to evaluate the applicability. According to the WF aggregation steps, the impact of various clustering methods on applicability is first explored, followed by the collector line aggregation method and the clustering scale. The results show that the clustering method based on WF layout is recommended for HFO analysis, while the collector line aggregation method based on equal power loss and weighted voltage difference have the same applicability. The clustering scale is suggested to be determined according to the length of the external collector line of each string. The above findings can provide a meaningful reference for the selection of WF aggregation methods for HFO analysis.


  • A Frequency Estimation-Based Adaptive Mitigation Approach for High-Frequency Oscillation in MMC-HVDC System

    by Chunyi Guo, Dongye Du, Hao Cheng, Fanxin Gan

    To suppress the high-frequency oscillations (HFOs) in Modular Multilevel Converter based High Voltage Direct Current (MMC-HVDC) transmission system, this article proposes a frequency estimation-based adaptive mitigation approach, including the oscillation frequency estimation (OFE) function and the oscillation suppression function by band-stop filter (BSF). Firstly, the proposed OFE function which is based on the rotating frame transformation and LPF can mitigate the influence of background harmonics, and rapidly identify frequency and amplitude of the HFO. Then, a BSF with adaptively corrected parameters, based on the identified frequency from OFE function, is embedded in the inner control loop of MMC to regulate the system damping in the interested frequency range. Thus, the impedance characteristic of MMC system in the oscillation frequency band can be adaptively reshaped to mitigate the HFO. The working principle of OFE function and suppression function by BSF is presented, and the parameters selection procedures are also provided. Finally, the proposed approach is validated by electromagnetic transient (EMT) simulations and controller hardware-in-the-loop (HIL) experiments. The results show that the presented adaptive mitigation approach shows a favorable identification and oscillation suppression ability for the HFOs.