JHJ. Y. Hua

J. Y. Hua

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


J. Y. Hua has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Narrowband THz radiation from laser wakefields driven in uniform plasma via tight laser focusing

    by J Y Hua, L Z Wang, Y P Chen, M Chen, S M Weng, Z M Sheng

    We propose a mechanism for generating narrowband terahertz (THz) radiation from laser wakefields via laser defocusing in uniform plasma. The defocused laser pulse induces a positive pseudo-density gradient, leading to a superluminal wakefield that emits Cherenkov-like radiation at harmonics of the electron plasma frequency. The radiation is radially polarized, typically with a bandwidth around 1%. Simulation results show that the THz energy scales with the fourth order of the laser intensity for weakly relativistic intense lasers and is inversely proportional to the beam waist. Larger focal spots reduce radiation power but improve its directivity. Under highly relativistic intensity, nonlinear wakefields can generate harmonic THz structures with narrow spectra, further enhancing the frequency tunability of the radiation for different applications.


  • Open Access

    Cherenkov-type coherent radiation from laser wakefields driven in nonuniform plasma

    by J. Y. Hua, L. Z. Wang, Y. P. Chen, M. Chen, S. M. Weng, Z. M. Sheng

    The evolution of the laser wakefields driven in a plasma slab with a longitudinal up-ramp density profile and the associated radiation are investigated theoretically and numerically by using two-dimensional particle-in-cell simulations. The radiation shows a conical distribution along the laser propagation direction, which is produced via the Cherenkov-type mechanism as the phase velocity of the wakefields is superluminal. The relationship between the radiation intensity and the laser focal spot size is found from simulation, which agrees with theory. At moderate laser intensity, the radiation shows a spectrum at harmonics of the electron plasma frequency. When the wakefields are excited in the highly nonlinear regime, the radiation spectrum shows a supercontinuum profile extending to a dozen times of the electron plasma frequency. Our results may be applied to optimize experimental parameters for enhanced radiation generation from the laser wakefields.


  • Open Access

    Enhanced terahertz radiation generated by intense laser interaction with a two-layer thin solid target

    by J. Y. Hua, X. B. Zhang, M. Chen, S. M. Weng, Y. P. Chen, Z. M. Sheng

    A terahertz radiation enhancing scheme, in which a linearly polarized weakly relativistic laser pulse irradiates a target consisting of two parallel thin-solid layers with a certain gap, is proposed and studied by using two-dimensional particle-in-cell simulations. The radiation is known to be produced by laser-produced hot electrons via mechanisms such as coherent transition radiation at the target surfaces. Under optimized conditions, the energy conversion efficiency of terahertz radiation can be as high as 3.3%, which is nearly 1.5 times higher than that obtained with a single-layer target with the same drive laser. This is mainly due to the enhanced hot electron generation with moderate energy via multiple reflections of the laser pulse between the two target layers. The radiation has two peaks close to 30° from the target surface, which are more collimated than that with the single-layer target. The dependence of the terahertz radiation on a variety of target parameters is given, which can control the terahertz spectrum and radiation efficiency and thus provide guidance for experimental investigations. Moreover, both the coherent transition radiation and antenna radiation models are applied to explain the angular distributions of the terahertz emission found in the simulations. Published by the American Physical Society 2024


  • Open Access

    Using the apparent diffusion coefficient histogram analysis to predict response to neoadjuvant chemotherapy in patients with breast cancer: comparison among three region of interest selection methods

    by Xiaochuan Geng, Dandan Zhang, Shiteng Suo, Jie Chen, Fang Cheng, Kebei Zhang, Qing Zhang, Lan Li, Yang Lu, Jia Hua, et al.

    Background: The apparent diffusion coefficient (ADC) value using histogram analysis is helpful to predict responses to neoadjuvant chemotherapy (NAC) in breast cancer. However, the measurement method has not reached a consensus. This study was to assess the diagnostic performance of the ADC histogram analysis at predicting patient response prior to NAC in breast cancer patients using different region of interest (ROI) selection methods. Methods: A total of 75 patients who underwent diffusion weighted imaging (DWI) prior to NAC were retrospectively enrolled from February 2017 to December 2019. Images were measured using small 2-dimensional (2D) ROI, large 2D ROI, and volume ROI methods. The measurement time and ROI size were recorded. Histopathologic responses were acquired using the Miller-Payne grading system after surgery. The inter- and intra-observer repeatability was analyzed and the ADC histogram values from the three ROI methods were compared. The efficacy of each method at predicting patient response prior to NAC was assessed using the area under the receiver operating characteristic curve (AUC) for the whole study population and subgroups according to molecular subtype. Results: Among the 75 enrolled patients, 26 (34.67%) were responsive to NAC therapy. The ADC histogram values were significantly different among the three ROI methods (P≤0.038). Inter- and intra-observer repeatability of the large 2D ROI method and the volume ROI method was generally greater than that observed with the 2D ROI method. The 10% ADC value of the large 2D ROI method showed the greatest AUC (0.701) in the whole study population and in the luminal subgroup (AUC 0.804). The volume ROI method required significantly more time than the other two ROI methods (PConclusions: The small 2D ROI method is not appropriate for predicting response prior to NAC in breast cancer patients due to the poor repeatability. When choosing the ROI method and the histogram parameters for predicting response prior to NAC in breast cancer patients using ADC-derived histogram analysis, 10% of the large 2D ROI method is recommended, especially in luminal A subtype patients.


  • Standard operating procedure for metabonomics studies of blood serum and plasma samples using a 1H‐NMR micro‐flow probe

    by Dinesh K. Sukumaran, Erwin Garcia, Jia Hua, Walter Tabaczynski, Kunle Odunsi, Chris Andrews, Thomas Szyperski

    A standard operating procedure (SOP) is presented for high‐throughput metabonomics studies using a 600 MHz NMR spectrometer equipped with a micro‐flow probe that is connected to an auto‐sampler. The procedure is designed to minimize random and systematic variation of NMR data collection. In addition, a protocol is described to assess the quality of the data acquired by a given NMR spectroscopist to ensure that (i) all researchers involved in the NMR data acquisition of a metabonomics research program perform equally and (ii) operator‐associated variation of NMR data collection is statistically not relevant for the interpretation of results obtained from multivariate data analyses. Copyright © 2009 John Wiley & Sons, Ltd.