Evgeniy V. Chartorizhsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Evgeniy V. Chartorizhsky has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Evgeniy V. Polezhankin
Kirov Military Medical Academy
1 shared publication - Kirill A. Tsygankov
Kirov Military Medical Academy
1 shared publication - Roman E. Lakhin
Kirov Military Medical Academy; Saratov State Medical University named after V.I. Razumovsky
1 shared publication - Vasiliy G. Tsvetkov
Kirov Military Medical Academy
1 shared publication - Цветков Василий Геннадьевич
Военно-медицинская академия имени С.М. Кирова
1 shared publication
Latest Publications
- 1 August 2024
- Published by ECO-Vector LLC in Regional Anesthesia and Acute Pain Management
- Vol. 18 (2) , 133-141
Optimization of ultrasound navigation techniques for brachial plexus block using proximal subclavian access
BACKGROUND: When performing a brachial plexus block in the proximal subclavian region, the scanning plane is located deeper and posterior to the clavicle midpoint. Data on the angle of the ultrasound probe and visualization of the brachial plexus bundles are limited. AIM: Our aim was to evaluate visualization and positioning of the neurovascular bundle in the infraclavicular region for proximal brachial plexus block.. MATERIALS AND METHODS: Volunteer patients (добровольцах (n=28, median — 43 years)) at the Military Traumatology and Orthopedics Clinic of the Military Medical Academy, named after S.M. Kirov, were studied. Ultrasound navigation was used to evaluate the neurovascular bundle followed by brachial plexus block. RESULTS: The study showed that the brachial plexus bundle is best visualized at an average sensor angle of between 90° and the maximum that allows visualization of at least one of the elements of the brachial plexus 64.4° (65.7°, 63°) and amounted to 77.5° (77.9°, 76.5°). CONCLUSION: The optimal angle for performing a brachial plexus block using the proximal subclavian approach is 77.5°. Optimal visualization of the brachial plexus is possible in the angle range from 64.4° to 90°, which enables selecting the safest trajectory of the needle when performing a blockade in this area, considering the anatomical characteristics of the patient. Further studies are required to compare the sensor angles used in actual clinical practice to the angles obtained in this study.
- 1 August 2024
- Published by ECO-Vector LLC in Regional Anesthesia and Acute Pain Management
- Vol. 18 (2) , 133-141
Optimization of ultrasound navigation techniques for brachial plexus block using proximal subclavian access
BACKGROUND: When performing a brachial plexus block in the proximal subclavian region, the scanning plane is located deeper and posterior to the clavicle midpoint. Data on the angle of the ultrasound probe and visualization of the brachial plexus bundles are limited. AIM: Our aim was to evaluate visualization and positioning of the neurovascular bundle in the infraclavicular region for proximal brachial plexus block.. MATERIALS AND METHODS: Volunteer patients (добровольцах (n=28, median — 43 years)) at the Military Traumatology and Orthopedics Clinic of the Military Medical Academy, named after S.M. Kirov, were studied. Ultrasound navigation was used to evaluate the neurovascular bundle followed by brachial plexus block. RESULTS: The study showed that the brachial plexus bundle is best visualized at an average sensor angle of between 90° and the maximum that allows visualization of at least one of the elements of the brachial plexus 64.4° (65.7°, 63°) and amounted to 77.5° (77.9°, 76.5°). CONCLUSION: The optimal angle for performing a brachial plexus block using the proximal subclavian approach is 77.5°. Optimal visualization of the brachial plexus is possible in the angle range from 64.4° to 90°, which enables selecting the safest trajectory of the needle when performing a blockade in this area, considering the anatomical characteristics of the patient. Further studies are required to compare the sensor angles used in actual clinical practice to the angles obtained in this study.