Abdelhak Kechida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelhak Kechida has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Belgacem Toual
Electrical Engineering Department Renewable Energy Systems Applications Laboratory (LASER), Ziane Achour University, 17000 Djelfa, Algeria
2 shared publications - Djamal Gozim
Applied Automation and Industrial Diagnostics Laboratory, Ziane Achour University Djelfa, Djelfa, Algeria
2 shared publications - Djamal Gozim
Laboratory of Applied Automation and Industrial Diagnostics (LAADI), Faculty of Science and Technology, Ziane Achour University, 17000 Djelfa, Algeria
2 shared publications - Abdallah Azzouz
Laboratory of Advanced Electronic Systems (LSEA), University of Médéa, Médéa 26000, Algeria
1 shared publication - Abdelaziz Rabehi
Telecommunication and Smart Systems Laboratory, Faculty of Sciences and Technology, Ziane Achour University, Djelfa 17000, Algeria
1 shared publication Belgacem Toual
Renewable Energy Systems Applications Laboratory (LASER), Ziane Achour University Djelfa, Djelfa, Algeria
1 shared publication
Latest Publications
- Open Access
A Simulation-Based Digital Twin for Condition-Based Waterless Cleaning of Photovoltaic Plants in Arid Regions
Dust-induced soiling reduces photovoltaic (PV) energy yield in arid regions, while calendar-based cleaning ignores differences between rows. This study proposes a lightweight, estimation-centered digital twin (DT) whose closed loop is simulated only. It fuses inverter-derived power ratios with intermittent camera information in a Kalman filter with power-channel bias correction and is designed to schedule waterless robotic cleaning with an economic decision rule. In 50 Monte Carlo runs of a simulated 1 MWp plant calibrated on published data from Laghouat, Algeria, the fused estimator achieved a mean absolute soiling error of 0.56 percentage points, against 1.48 for a power-only estimator and 0.48 with a simulated clean/dusty classifier. The fused policy increased the annual net benefit by 0.31 k€ per MWp (0.63%) over the best fixed waterless schedule, in all 50 runs. Most of the economic gain comes from the camera (camera-only +0.27 k€ against +0.31 k€ fused); the fusion mainly improves accuracy and robustness to power-channel bias. This gain is small: for an assumed fixed cost of 20 k€, the twin pays for itself only on plants of about 9.6 MWp or more, or with a low-cost camera. On 181 days of measured power data with a simulated camera, its error stayed at 1.2–1.3 points under −2% to +4% expected-power bias. A MobileNetV2 classifier reached 84.4% mean test accuracy on 1150 public images but did not transfer to a second public image set. The present results lay the groundwork for subsequent field deployment of the camera-based sensing, robotic actuation, and closed-loop control.
Open AccessA Simulation-Based Digital Twin for Condition-Based Waterless Cleaning of Photovoltaic Plants in Arid Regions
Dust-induced soiling reduces photovoltaic (PV) energy yield in arid regions, while calendar-based cleaning ignores differences between rows. This study proposes a lightweight, estimation-centered digital twin (DT) whose closed loop is simulated only. It fuses inverter-derived power ratios with intermittent camera information in a Kalman filter with power-channel bias correction and is designed to schedule waterless robotic cleaning with an economic decision rule. In 50 Monte Carlo runs of a simulated 1 MWp plant calibrated on published data from Laghouat, Algeria, the fused estimator achieved a mean absolute soiling error of 0.56 percentage points, against 1.48 for a power-only estimator and 0.48 with a simulated clean/dusty classifier. The fused policy increased the annual net benefit by 0.31 k€ per MWp (0.63%) over the best fixed waterless schedule, in all 50 runs. Most of the economic gain comes from the camera (camera-only +0.27 k€ against +0.31 k€ fused); the fusion mainly improves accuracy and robustness to power-channel bias. This gain is small: for an assumed fixed cost of 20 k€, the twin pays for itself only on plants of about 9.6 MWp or more, or with a low-cost camera. On 181 days of measured power data with a simulated camera, its error stayed at 1.2–1.3 points under −2% to +4% expected-power bias. A MobileNetV2 classifier reached 84.4% mean test accuracy on 1150 public images but did not transfer to a second public image set. The present results lay the groundwork for subsequent field deployment of the camera-based sensing, robotic actuation, and closed-loop control.
- Open Access
- 4 June 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (3) , 23988-23994
Optimal Control of Bi-directional Converter to Enhance the Performance of an off-Grid Hybrid System
This paper presents a new method based on Artificial Intelligence (AI), for the optimal control of a bidirectional converter. The goal is to improve the DC bus voltage efficiency of a grid-independent hybrid system. The proposed design consists of a Photovoltaic System (PVS), a Wind Energy Conversion System (WECS), a Battery Storage System (BSS), and a variety of electronic power devices to extract the maximum energy from the generation sources. A bidirectional converter is featured in the use of an Adaptive Network-based Fuzzy Inference System (ANFIS) based controller, to improve the energy quality of the DC bus. The proposed approach provided good results compared to the Proportional Integral (PI) controller and the Fuzzy Logic controller (FLC). The use of this approach reduced the value of oscillations, improved the response time of the system, and contributed to the elimination of the problem of overshoot. This experiment was conducted using Matlab and Simulink.
- 4 June 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (3) , 23988-23994
Open AccessOptimal Control of Bi-directional Converter to Enhance the Performance of an off-Grid Hybrid System
This paper presents a new method based on Artificial Intelligence (AI), for the optimal control of a bidirectional converter. The goal is to improve the DC bus voltage efficiency of a grid-independent hybrid system. The proposed design consists of a Photovoltaic System (PVS), a Wind Energy Conversion System (WECS), a Battery Storage System (BSS), and a variety of electronic power devices to extract the maximum energy from the generation sources. A bidirectional converter is featured in the use of an Adaptive Network-based Fuzzy Inference System (ANFIS) based controller, to improve the energy quality of the DC bus. The proposed approach provided good results compared to the Proportional Integral (PI) controller and the Fuzzy Logic controller (FLC). The use of this approach reduced the value of oscillations, improved the response time of the system, and contributed to the elimination of the problem of overshoot. This experiment was conducted using Matlab and Simulink.
- Open Access
- 30 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-19
Smart control and management for a renewable energy based stand-alone hybrid system
This paper addresses the smart management and control of an independent hybrid system based on renewable energies. The suggested system comprises a photovoltaic system (PVS), a wind energy conversion system (WECS), a battery storage system (BSS), and electronic power devices that are controlled to enhance the efficiency of the generated energy. Regarding the load side, the system comprises AC loads, DC loads, and a water pump. An Adaptive Neuro-Fuzzy Inference System (ANFIS)-based MPPT technique is suggested to enhance the efficiency of the PVS and WECS. This technology provided good performance compared with the Perturb and Observe (P&O) algorithm and MPPT-based fuzzy logic controller (FLC). The use of the ANFIS-PI proposed to control the bidirectional converter accomplished voltage stabilization for the DC bus. This work also came with a fuzzy logic-based algorithm to manage the load side that depends on battery charge ratio, solar radiation, and wind speed. According to results obtained in the MATLAB/Simulink environment, the proposed technologies were found to have performed well. The goal we were also pursuing was achieved through the full use of the energy generated by the proposed algorithm. The proposed study holds great potential for remote regions.
- 30 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-19
Open AccessSmart control and management for a renewable energy based stand-alone hybrid system
This paper addresses the smart management and control of an independent hybrid system based on renewable energies. The suggested system comprises a photovoltaic system (PVS), a wind energy conversion system (WECS), a battery storage system (BSS), and electronic power devices that are controlled to enhance the efficiency of the generated energy. Regarding the load side, the system comprises AC loads, DC loads, and a water pump. An Adaptive Neuro-Fuzzy Inference System (ANFIS)-based MPPT technique is suggested to enhance the efficiency of the PVS and WECS. This technology provided good performance compared with the Perturb and Observe (P&O) algorithm and MPPT-based fuzzy logic controller (FLC). The use of the ANFIS-PI proposed to control the bidirectional converter accomplished voltage stabilization for the DC bus. This work also came with a fuzzy logic-based algorithm to manage the load side that depends on battery charge ratio, solar radiation, and wind speed. According to results obtained in the MATLAB/Simulink environment, the proposed technologies were found to have performed well. The goal we were also pursuing was achieved through the full use of the energy generated by the proposed algorithm. The proposed study holds great potential for remote regions.
- Open Access
- 2 January 2024
- Published by Brazilian Journals in STUDIES IN ENGINEERING AND EXACT SCIENCES
- Vol. 5 (1) , 97-113
Management stand-alone hybrid renewable energy system based on wind and solar with battery storage
This paper describes the management of a standalone hybrid energy system (HES) based on two renewable sources. The sun, wind. and the battery supports the system. Solar panels and wind turbines (WT) connected with permanent magnet synchronous generators (PMSG) were used for power production. Power converters have been used together with control algorithms for efficient power management. The filters were used to dispose of the largest amount of harmonics in the inverter. The proposed model provides a strategy for managing energy under various generating conditions. In order to save energy for a fixed load. Proposed hybrid accession simulated with MATLAB/Simulink
- 2 January 2024
- Published by Brazilian Journals in STUDIES IN ENGINEERING AND EXACT SCIENCES
- Vol. 5 (1) , 97-113
Open AccessManagement stand-alone hybrid renewable energy system based on wind and solar with battery storage
This paper describes the management of a standalone hybrid energy system (HES) based on two renewable sources. The sun, wind. and the battery supports the system. Solar panels and wind turbines (WT) connected with permanent magnet synchronous generators (PMSG) were used for power production. Power converters have been used together with control algorithms for efficient power management. The filters were used to dispose of the largest amount of harmonics in the inverter. The proposed model provides a strategy for managing energy under various generating conditions. In order to save energy for a fixed load. Proposed hybrid accession simulated with MATLAB/Simulink
- Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Power Electronics and Drives
- Vol. 9 (1) , 397-411
Improving the Performance of Hybrid System-Based Renewable Energy by Artificial Intelligence
Artificial intelligence (AI) has emerged as a critical indicator of technological progress in recent years. The present study uses AI to enhance the efficiency of a hybrid system that operates on renewable energy sources. The hybrid system we propose consists of a wind energy conversion system (WECS), a photovoltaic system (PVS), a battery storage system (BSS) and electronic power converters. AI manages these converters cleverly. We use the maximum power point tracking (MPPT)-based fuzzy logic controller (FLC) to regulate the boost converter in the PVS and the WECS. We propose an adaptive neuro fuzzy inference system (ANFIS)-based controller to control the bidirectional converter of the storage system. The design of this module intends to maintain voltage stability on the direct current (DC) bus and improve energy quality. We study and simulate this system using MATLAB/SIMULINK. The results of this research show that the FLC-MPPT technique outperforms the Perturb and Observe (P&O) algorithm in terms of efficiency in power production. The console we propose also shows good results in maintaining the voltage stability in the DC bus in comparison with the proportional integral (PI) controller. This paper has the potential to contribute to the development of environmentally friendly resource performance.
- 1 January 2024
- Published by Walter de Gruyter GmbH in Power Electronics and Drives
- Vol. 9 (1) , 397-411
Open AccessImproving the Performance of Hybrid System-Based Renewable Energy by Artificial Intelligence
Artificial intelligence (AI) has emerged as a critical indicator of technological progress in recent years. The present study uses AI to enhance the efficiency of a hybrid system that operates on renewable energy sources. The hybrid system we propose consists of a wind energy conversion system (WECS), a photovoltaic system (PVS), a battery storage system (BSS) and electronic power converters. AI manages these converters cleverly. We use the maximum power point tracking (MPPT)-based fuzzy logic controller (FLC) to regulate the boost converter in the PVS and the WECS. We propose an adaptive neuro fuzzy inference system (ANFIS)-based controller to control the bidirectional converter of the storage system. The design of this module intends to maintain voltage stability on the direct current (DC) bus and improve energy quality. We study and simulate this system using MATLAB/SIMULINK. The results of this research show that the FLC-MPPT technique outperforms the Perturb and Observe (P&O) algorithm in terms of efficiency in power production. The console we propose also shows good results in maintaining the voltage stability in the DC bus in comparison with the proportional integral (PI) controller. This paper has the potential to contribute to the development of environmentally friendly resource performance.