Qunran Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qunran Yuan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Changqing Jiang
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
2 shared publications Hongda Li
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication- Luming Li
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University; IDG/McGovern Institute for Brain Research, Tsinghua University
1 shared publication Ru Ma
Beijing PINS Medical Company Ltd., Beijing, China
1 shared publication- Shunjing Wang
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication - Tiangang Long
National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1685-1694
Efficient, Robust, and Accurate CNN Predictor for Neuronal Activation in Directional Deep Brain Stimulation
The programming of clinical deep brain stimulation (DBS) systems involves numerous combinations of stimulation parameters, such as stimulus amplitude, pulse width, and frequency. As more complex electrode designs, such as directional electrodes, are introduced, the traditional trial-and-error approach to manual DBS programming becomes increasingly impractical. Visualization of the volume of tissue activated (VTA) can assist in selecting stimulation parameters by showing the direct effects of DBS on neural tissue. However, the standard method for VTA calculation, which involves modeling biological nerve fibers, is highly time-consuming and limits clinical applicability. In this study, we used finite element models (FEM) of implanted DBS systems to compute electric fields and obtained a large dataset of axonal responses under electrical stimulation using multicompartment cable models. We then trained a convolutional neural network (CNN) to replace the cable models. The CNN model’s performance in calculating VTA was evaluated across various electrode configurations and stimulation parameters, and compared with existing activation function (AF) methods. The CNN model achieved a mean absolute error (MAE) of 0.032V in predicting nerve fiber activation thresholds, demonstrating greater stability and accuracy in VTA prediction compared to the AF method. Additionally, the CNN reduced computation time by five orders of magnitude compared to standard axonal modeling methods. We demonstrate that the CNN-based neural fiber predictor can quickly, accurately, and robustly predict neural activation responses to DBS, thereby improving the efficiency of DBS programming.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1685-1694
Open AccessEfficient, Robust, and Accurate CNN Predictor for Neuronal Activation in Directional Deep Brain Stimulation
The programming of clinical deep brain stimulation (DBS) systems involves numerous combinations of stimulation parameters, such as stimulus amplitude, pulse width, and frequency. As more complex electrode designs, such as directional electrodes, are introduced, the traditional trial-and-error approach to manual DBS programming becomes increasingly impractical. Visualization of the volume of tissue activated (VTA) can assist in selecting stimulation parameters by showing the direct effects of DBS on neural tissue. However, the standard method for VTA calculation, which involves modeling biological nerve fibers, is highly time-consuming and limits clinical applicability. In this study, we used finite element models (FEM) of implanted DBS systems to compute electric fields and obtained a large dataset of axonal responses under electrical stimulation using multicompartment cable models. We then trained a convolutional neural network (CNN) to replace the cable models. The CNN model’s performance in calculating VTA was evaluated across various electrode configurations and stimulation parameters, and compared with existing activation function (AF) methods. The CNN model achieved a mean absolute error (MAE) of 0.032V in predicting nerve fiber activation thresholds, demonstrating greater stability and accuracy in VTA prediction compared to the AF method. Additionally, the CNN reduced computation time by five orders of magnitude compared to standard axonal modeling methods. We demonstrate that the CNN-based neural fiber predictor can quickly, accurately, and robustly predict neural activation responses to DBS, thereby improving the efficiency of DBS programming.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Translational Excitation Strategy for Scaled Transfer Function Measurement of Medical Implants
The transfer function (TF) of a medical implant is critical for radiofrequency (RF)-induced heating evaluation during MRI scans. Conventionally, the calibration and validation of the TF are intertwined processes that rely on RF exposure experiments. This coupling can result in unvalidated scale factors and raise safety concerns for patients. To address this issue, we introduce the translational excitation strategy (TES), a method for independently measuring the scaled TF based on the principles of the induction and reciprocity theorems. TES allows the RF exposure experiment to serve as an independent validation step for the TF. We present both numerical simulations and experimental results to demonstrate the validity of this method. Moreover, TES enhances the efficiency of TF acquisition, offering a pioneering platform for advancing studies on the electromagnetic models of implants.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Translational Excitation Strategy for Scaled Transfer Function Measurement of Medical Implants
The transfer function (TF) of a medical implant is critical for radiofrequency (RF)-induced heating evaluation during MRI scans. Conventionally, the calibration and validation of the TF are intertwined processes that rely on RF exposure experiments. This coupling can result in unvalidated scale factors and raise safety concerns for patients. To address this issue, we introduce the translational excitation strategy (TES), a method for independently measuring the scaled TF based on the principles of the induction and reciprocity theorems. TES allows the RF exposure experiment to serve as an independent validation step for the TF. We present both numerical simulations and experimental results to demonstrate the validity of this method. Moreover, TES enhances the efficiency of TF acquisition, offering a pioneering platform for advancing studies on the electromagnetic models of implants.