Faizah Mohammed Bashir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Faizah Mohammed Bashir has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Yakubu Aminu Dodo
5 shared publications- Yakubu Aminu Dodo
Architectural Engineering Department, College of Engineering, Najran University, Najran 66426, Saudi Arabia
4 shared publications Ibtihaj Saad Rashed Alsadun
3 shared publications- Khaled Almazam
Architectural Engineering Department, College of Engineering, Najran University, Najran 66426, Saudi Arabia
3 shared publications Zahra Andleeb
3 shared publications- Haifa Youssef Hamdoun2 shared publications
Latest Publications
- 19 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
A phase-change-cooled, naturally ventilated Photovoltaic–thermal colored façade for hot-arid residential envelopes
- 19 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
A phase-change-cooled, naturally ventilated Photovoltaic–thermal colored façade for hot-arid residential envelopes
- Open Access
Synergistic Air Quality and Cooling Efficiency in Office Space with Indoor Green Walls
Enhancing indoor environmental quality while reducing building energy consumption represents a critical challenge for sustainable building design, particularly in hot arid climates where cooling loads dominate energy use. Despite extensive research on green wall systems (GWSs), robust quantitative data on their combined impact on air quality and thermal performance in real-world office environments remains limited. This research quantified the synergistic effects of an active indoor green wall system on key indoor air quality indicators and cooling energy consumption in a contemporary office environment. A comparative field study was conducted over 12 months in two identical office rooms in Dhahran, Saudi Arabia, with one room serving as a control while the other was retrofitted with a modular hydroponic green wall system. High-resolution sensors continuously monitored indoor CO2, volatile organic compounds via photoionization detection (VOC_PID; isobutylene-equivalent), and PM2.5 concentrations, alongside dedicated sub-metering of cooling energy consumption. The green wall system achieved statistically significant improvements across all parameters: 14.1% reduction in CO2 concentrations during occupied hours, 28.1% reduction in volatile organic compounds, 20.9% reduction in PM2.5, and 13.5% reduction in cooling energy consumption (574.5 kWh annually). Economic analysis indicated financial viability (2.0-year payback; benefit–cost ratio 3.0; 15-year net present value SAR 31,865). Productivity-related benefits were valued from published relationships rather than measured in this study; base-case viability remained strictly positive in energy-only and conservative sensitivity scenarios. Strong correlations were established between evapotranspiration rates and cooling benefits (r = 0.734), with peak performance during summer months reaching 17.1% energy savings. Active indoor GWSs effectively function as multifunctional strategies, delivering simultaneous air quality improvements and measurable cooling energy reductions through evapotranspiration-mediated mechanisms, supporting their integration into sustainable building design practices.
Open AccessSynergistic Air Quality and Cooling Efficiency in Office Space with Indoor Green Walls
Enhancing indoor environmental quality while reducing building energy consumption represents a critical challenge for sustainable building design, particularly in hot arid climates where cooling loads dominate energy use. Despite extensive research on green wall systems (GWSs), robust quantitative data on their combined impact on air quality and thermal performance in real-world office environments remains limited. This research quantified the synergistic effects of an active indoor green wall system on key indoor air quality indicators and cooling energy consumption in a contemporary office environment. A comparative field study was conducted over 12 months in two identical office rooms in Dhahran, Saudi Arabia, with one room serving as a control while the other was retrofitted with a modular hydroponic green wall system. High-resolution sensors continuously monitored indoor CO2, volatile organic compounds via photoionization detection (VOC_PID; isobutylene-equivalent), and PM2.5 concentrations, alongside dedicated sub-metering of cooling energy consumption. The green wall system achieved statistically significant improvements across all parameters: 14.1% reduction in CO2 concentrations during occupied hours, 28.1% reduction in volatile organic compounds, 20.9% reduction in PM2.5, and 13.5% reduction in cooling energy consumption (574.5 kWh annually). Economic analysis indicated financial viability (2.0-year payback; benefit–cost ratio 3.0; 15-year net present value SAR 31,865). Productivity-related benefits were valued from published relationships rather than measured in this study; base-case viability remained strictly positive in energy-only and conservative sensitivity scenarios. Strong correlations were established between evapotranspiration rates and cooling benefits (r = 0.734), with peak performance during summer months reaching 17.1% energy savings. Active indoor GWSs effectively function as multifunctional strategies, delivering simultaneous air quality improvements and measurable cooling energy reductions through evapotranspiration-mediated mechanisms, supporting their integration into sustainable building design practices.
- Open Access
Integrating BIM, Machine Learning, and PMBOK for Green Project Management in Saudi Arabia: A Framework for Energy Efficiency and Environmental Impact Reduction
This study introduces a comprehensive framework combining building information modeling (BIM), project management body of knowledge (PMBOK), and machine learning (ML) to optimize energy efficiency and reduce environmental impacts in Riyadh’s construction sector. The suggested methodology utilizes BIM for dynamic energy simulations and design visualization, PMBOK for integrating sustainability into project-management processes, and ML for predictive modeling and real-time energy optimization. Implementing an integrated model that incorporates building-management strategies and machine learning for both commercial and residential structures can offer stakeholders a thorough solution for forecasting energy performance and environmental impact. This is particularly essential in arid climates owing to specific conditions and environmental limitations. Using a simulation-based methodology, the framework was evaluated based on two representative case studies: (i) a commercial complex and (ii) a residential building. The neural network (NN), reinforcement learning (RL), and decision tree (DT) were implemented to assess performance in energy prediction and optimization. Results demonstrated notable seasonal energy savings, particularly in spring (15% reduction for commercial buildings) and fall (13% reduction for residential buildings), driven by optimized heating, ventilation, and air conditioning (HVAC) systems, insulation strategies, and window configurations. ML models successfully predicted energy consumption and greenhouse gas (GHG) emissions, enabling targeted mitigation strategies. GHG emissions were reduced by up to 25% in commercial and 20% in residential settings. Among the models, NN achieved the highest predictive accuracy (R2 = 0.95), while RL proved effective in adaptive operational control. This study highlights the synergistic potential of BIM, PMBOK, and ML in advancing green project management and sustainable construction.
Open AccessIntegrating BIM, Machine Learning, and PMBOK for Green Project Management in Saudi Arabia: A Framework for Energy Efficiency and Environmental Impact Reduction
This study introduces a comprehensive framework combining building information modeling (BIM), project management body of knowledge (PMBOK), and machine learning (ML) to optimize energy efficiency and reduce environmental impacts in Riyadh’s construction sector. The suggested methodology utilizes BIM for dynamic energy simulations and design visualization, PMBOK for integrating sustainability into project-management processes, and ML for predictive modeling and real-time energy optimization. Implementing an integrated model that incorporates building-management strategies and machine learning for both commercial and residential structures can offer stakeholders a thorough solution for forecasting energy performance and environmental impact. This is particularly essential in arid climates owing to specific conditions and environmental limitations. Using a simulation-based methodology, the framework was evaluated based on two representative case studies: (i) a commercial complex and (ii) a residential building. The neural network (NN), reinforcement learning (RL), and decision tree (DT) were implemented to assess performance in energy prediction and optimization. Results demonstrated notable seasonal energy savings, particularly in spring (15% reduction for commercial buildings) and fall (13% reduction for residential buildings), driven by optimized heating, ventilation, and air conditioning (HVAC) systems, insulation strategies, and window configurations. ML models successfully predicted energy consumption and greenhouse gas (GHG) emissions, enabling targeted mitigation strategies. GHG emissions were reduced by up to 25% in commercial and 20% in residential settings. Among the models, NN achieved the highest predictive accuracy (R2 = 0.95), while RL proved effective in adaptive operational control. This study highlights the synergistic potential of BIM, PMBOK, and ML in advancing green project management and sustainable construction.
- Open Access
- 25 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (7) , 2916
Innovative Energy Efficiency in HVAC Systems with an Integrated Machine Learning and Model Predictive Control Technique: A Prospective Toward Sustainable Buildings
This study introduces a novel approach, combining radial basis function neural network (RBFNN) and model predictive control (MPC) techniques to enhance energy efficiency in HVAC systems for sustainable buildings. The proposed methodology is evaluated in a single-story commercial and residential building in Najran, Saudi Arabia, utilizing new input parameters such as ambient temperature, cooling load, and compressor speed, alongside output metrics including room temperature and total exergy destruction and coefficient of performance (CoP) of the HVAC system. Significant improvements in energy management practices were observed, with a reduction in energy consumption by approximately 15% compared to conventional control models. The model’s predictive capabilities were validated against real-world electricity consumption data, demonstrating a high correlation with discrepancies ranging from 0.2% to 2.5%. Furthermore, the integration of machine learning techniques enabled more precise control of HVAC operations, addressing concerns regarding the system’s dynamic behavior and optimizing performance under varying occupancy patterns. While in the commercial building, the model achieves RMSE and CV values of approximately 1.0 and 0.61 for room temperature, 1.21 and 0.48 for exergy destruction, and 0.65 and 0.30 for CoP. However, for the residential building, RMSE and CV values are approximately 0.95 and 0.69 for room temperature, 1.08 and 0.31 for exergy destruction, and 0.55 and 0.27 for CoP.
- 25 March 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (7) , 2916
Open AccessInnovative Energy Efficiency in HVAC Systems with an Integrated Machine Learning and Model Predictive Control Technique: A Prospective Toward Sustainable Buildings
This study introduces a novel approach, combining radial basis function neural network (RBFNN) and model predictive control (MPC) techniques to enhance energy efficiency in HVAC systems for sustainable buildings. The proposed methodology is evaluated in a single-story commercial and residential building in Najran, Saudi Arabia, utilizing new input parameters such as ambient temperature, cooling load, and compressor speed, alongside output metrics including room temperature and total exergy destruction and coefficient of performance (CoP) of the HVAC system. Significant improvements in energy management practices were observed, with a reduction in energy consumption by approximately 15% compared to conventional control models. The model’s predictive capabilities were validated against real-world electricity consumption data, demonstrating a high correlation with discrepancies ranging from 0.2% to 2.5%. Furthermore, the integration of machine learning techniques enabled more precise control of HVAC operations, addressing concerns regarding the system’s dynamic behavior and optimizing performance under varying occupancy patterns. While in the commercial building, the model achieves RMSE and CV values of approximately 1.0 and 0.61 for room temperature, 1.21 and 0.48 for exergy destruction, and 0.65 and 0.30 for CoP. However, for the residential building, RMSE and CV values are approximately 0.95 and 0.69 for room temperature, 1.08 and 0.31 for exergy destruction, and 0.55 and 0.27 for CoP.
- Open Access
- 26 July 2024
- Published by IWA Publishing in Water Science & Technology
- Vol. 90 (3) , 968-984
A novel approach to integrate CCHP systems with desalination for sustainable energy and water solutions in educational buildings
This study presents a novel approach to integrating combined cooling, heating, and power (CCHP) systems with water desalination for enhanced energy and water management in educational buildings. Two distinct layouts for CCHP and desalination systems are introduced: one prioritizing efficient power generation to meet electricity demands while providing waste heat for desalination, and the other focusing on balancing cooling and heating loads alongside water desalination. Both layouts are tailored to meet the building's energy and water demands while considering operational efficiency. Optimization of these layouts against traditional systems using the bat search algorithm emphasizes economic viability and the gas engine's operational flexibility, which are crucial for partial load operation. In addition, an environmental assessment compares the proposed CCHP-desalination systems with conventional setups, assessing CO2 emission reductions and overall sustainability. The evaluation encompasses key environmental metrics, such as resource consumption and the integration of renewable energy sources. Results highlight significant CO2 emission reductions across various gas engine capacities, with notable enhancements in economic and environmental performance achieved by selecting a 3,250 kW gas engine within the CCHP-desalination system. This choice not only maximizes the annual profit but also reduces CO2 emissions by 57% compared to conventional systems, underscoring the system's sustainability benefits.
- 26 July 2024
- Published by IWA Publishing in Water Science & Technology
- Vol. 90 (3) , 968-984
Open AccessA novel approach to integrate CCHP systems with desalination for sustainable energy and water solutions in educational buildings
This study presents a novel approach to integrating combined cooling, heating, and power (CCHP) systems with water desalination for enhanced energy and water management in educational buildings. Two distinct layouts for CCHP and desalination systems are introduced: one prioritizing efficient power generation to meet electricity demands while providing waste heat for desalination, and the other focusing on balancing cooling and heating loads alongside water desalination. Both layouts are tailored to meet the building's energy and water demands while considering operational efficiency. Optimization of these layouts against traditional systems using the bat search algorithm emphasizes economic viability and the gas engine's operational flexibility, which are crucial for partial load operation. In addition, an environmental assessment compares the proposed CCHP-desalination systems with conventional setups, assessing CO2 emission reductions and overall sustainability. The evaluation encompasses key environmental metrics, such as resource consumption and the integration of renewable energy sources. Results highlight significant CO2 emission reductions across various gas engine capacities, with notable enhancements in economic and environmental performance achieved by selecting a 3,250 kW gas engine within the CCHP-desalination system. This choice not only maximizes the annual profit but also reduces CO2 emissions by 57% compared to conventional systems, underscoring the system's sustainability benefits.