Beatrice Crestani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Beatrice Crestani has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Davide Ferraro
University of Padua Via F. Marzolo 8
4 shared publications - Giampaolo Mistura
Dipartimento di Fisica e Astronomia “G. Galilei”, Università di Padova, via Marzolo 8, 35131 Padova, Italy
3 shared publications Noemi Torriero
University of Padua Via Marzolo 8
3 shared publicationsAndrea Vogliardi
2 shared publicationsFilippo Marinello
2 shared publicationsGianluca Ruffato
2 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 33468-33480
Improved-Purity Extracellular Vesicle Isolation Using Antibody−Aptamer Conjugates by Double-Droplet Microfluidics
Extracellular vesicles (EVs) are promising non-invasive biomarkers, but their isolation from complex biofluids remains a major analytical challenge due to low abundance, heterogeneity, and co-isolation of contaminants. Immunoaffinity capture using magnetic beads offers high selectivity; however, conventional workflows require multiple manual steps and often rely on harsh elution conditions that compromise the integrity and purity of the vesicles. Here, we report a droplet microfluidic platform that integrates reversible antibody−aptamer immunocapture, allowing magnetic bead handling for the isolation and gentle release of EVs directly from human plasma. The approach exploits double-droplet emulsions and magnetically assisted bead extraction to minimize residual supernatant and reduce contamination. The system is first validated using model contaminants, demonstrating up to a tenfold reduction in contaminant carryover compared with the corresponding bench-scale protocol. Then, the droplet microfluidic platform is applied for EV isolation from the human plasma without pre-enrichment, showing a recovery comparable to that of the conventional bench-scale method and a significant reduction in non-specific binding, indicating improved sample purity. Overall, this strategy combines reversible affinity chemistry with droplet microfluidics to enable EV isolation with improved purity, preserved vesicle morphology, and detectable EV-associated markers.
- 4 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 33468-33480
Open AccessImproved-Purity Extracellular Vesicle Isolation Using Antibody−Aptamer Conjugates by Double-Droplet Microfluidics
Extracellular vesicles (EVs) are promising non-invasive biomarkers, but their isolation from complex biofluids remains a major analytical challenge due to low abundance, heterogeneity, and co-isolation of contaminants. Immunoaffinity capture using magnetic beads offers high selectivity; however, conventional workflows require multiple manual steps and often rely on harsh elution conditions that compromise the integrity and purity of the vesicles. Here, we report a droplet microfluidic platform that integrates reversible antibody−aptamer immunocapture, allowing magnetic bead handling for the isolation and gentle release of EVs directly from human plasma. The approach exploits double-droplet emulsions and magnetically assisted bead extraction to minimize residual supernatant and reduce contamination. The system is first validated using model contaminants, demonstrating up to a tenfold reduction in contaminant carryover compared with the corresponding bench-scale protocol. Then, the droplet microfluidic platform is applied for EV isolation from the human plasma without pre-enrichment, showing a recovery comparable to that of the conventional bench-scale method and a significant reduction in non-specific binding, indicating improved sample purity. Overall, this strategy combines reversible affinity chemistry with droplet microfluidics to enable EV isolation with improved purity, preserved vesicle morphology, and detectable EV-associated markers.
- Open Access
- 14 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Robust and versatile refractive index optical detector for both monophasic and droplet-based microfluidics
- 14 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
Open AccessRobust and versatile refractive index optical detector for both monophasic and droplet-based microfluidics
- Open Access
- 6 June 2026
- Published by Elsevier in SSRN Electronic Journal
Robust and versatile Refractive Index Optical Detector for both monophasic and droplet-based microfluidics
Optofluidic technologies are based on the integration of optical components into microfluidic devices and are finding widespread applications in many fields, enabling advanced analytical functions such as refractive index (RI) sensing. However, current RI sensing platforms based on microfluidic devices rely on complex optical components, which limit their accessibility and scalability. Moreover, they are limited to monophasic microfluidics. In this work, we present a Refractive Index Optical Detector (RIOD) designed to operate with both monophasic and droplet-based flows within submillimetric capillaries. The RIOD employs two flexible light pipes that are aligned with a light-emitting diode (LED) and a photodiode by 3D printed parts. The device, controlled via an Arduino board, achieves RI sensitivity comparable to that of some existing and more complex systems, enabling the differentiation of various liquids and sucrose concentrations. Numerical simulations validate the working principle and assess the effect on the sensitivity of light wavelength and possible construction misalignments. Given the capability of monitoring liquids flowing in microchannels based on their refractive index, the RIOD is employed for real-time control of droplet motion. In detail, a proof-of-concept peroxidase fluorescent assay is reported, based on the automation of the droplet incubation by combining two RIODs with a syringe pump.
- 6 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRobust and versatile Refractive Index Optical Detector for both monophasic and droplet-based microfluidics
Optofluidic technologies are based on the integration of optical components into microfluidic devices and are finding widespread applications in many fields, enabling advanced analytical functions such as refractive index (RI) sensing. However, current RI sensing platforms based on microfluidic devices rely on complex optical components, which limit their accessibility and scalability. Moreover, they are limited to monophasic microfluidics. In this work, we present a Refractive Index Optical Detector (RIOD) designed to operate with both monophasic and droplet-based flows within submillimetric capillaries. The RIOD employs two flexible light pipes that are aligned with a light-emitting diode (LED) and a photodiode by 3D printed parts. The device, controlled via an Arduino board, achieves RI sensitivity comparable to that of some existing and more complex systems, enabling the differentiation of various liquids and sucrose concentrations. Numerical simulations validate the working principle and assess the effect on the sensitivity of light wavelength and possible construction misalignments. Given the capability of monitoring liquids flowing in microchannels based on their refractive index, the RIOD is employed for real-time control of droplet motion. In detail, a proof-of-concept peroxidase fluorescent assay is reported, based on the automation of the droplet incubation by combining two RIODs with a syringe pump.
- Open Access
Magnetic Stirring Device for Limiting the Sedimentation of Cells inside Microfluidic Devices
In experiments considering cell handling in microchannels, cell sedimentation in the storage container is a key problem because it affects the reproducibility of the experiments. Here, a simple and low-cost cell mixing device (CMD) is presented; the device is designed to prevent the sedimentation of cells in a syringe during their injection into a microfluidic channel. The CMD is based on a slider crank device made of 3D-printed parts that, combined with a permanent magnet, actuate a stir bar placed into the syringe containing the cells. By using A549 cell lines, the device is characterized in terms of cell viability (higher than 95%) in different mixing conditions, by varying the oscillation frequency and the overall mixing time. Then, a dedicated microfluidic experiment is designed to evaluate the injection frequency of the cells within a microfluidic chip. In the presence of the CMD, a higher number of cells are injected into the microfluidic chip with respect to the static conditions (2.5 times), proving that it contrasts cell sedimentation and allows accurate cell handling. For these reasons, the CMD can be useful in microfluidic experiments involving single-cell analysis.
Open AccessMagnetic Stirring Device for Limiting the Sedimentation of Cells inside Microfluidic Devices
In experiments considering cell handling in microchannels, cell sedimentation in the storage container is a key problem because it affects the reproducibility of the experiments. Here, a simple and low-cost cell mixing device (CMD) is presented; the device is designed to prevent the sedimentation of cells in a syringe during their injection into a microfluidic channel. The CMD is based on a slider crank device made of 3D-printed parts that, combined with a permanent magnet, actuate a stir bar placed into the syringe containing the cells. By using A549 cell lines, the device is characterized in terms of cell viability (higher than 95%) in different mixing conditions, by varying the oscillation frequency and the overall mixing time. Then, a dedicated microfluidic experiment is designed to evaluate the injection frequency of the cells within a microfluidic chip. In the presence of the CMD, a higher number of cells are injected into the microfluidic chip with respect to the static conditions (2.5 times), proving that it contrasts cell sedimentation and allows accurate cell handling. For these reasons, the CMD can be useful in microfluidic experiments involving single-cell analysis.