Andrea M. Rich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrea M. Rich has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jörg F. Löffler
Laboratory of Metal Physics and Technology Department of Materials ETH Zurich Zurich Switzerland
4 shared publications B. Schaller
Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland
2 shared publicationsK.M. Nuss
Musculoskeletal Research Unit, Vetsuisse Faculty ZH, University of Zurich, 8057 Zurich, Switzerland
2 shared publicationsLeopold Berger
Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
2 shared publications- Leopold Berger
Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
2 shared publications T. Akhmetshina
Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
2 shared publications
Latest Publications
- Open Access
- 11 March 2025
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 173, 214285
Bioresorbable, amorphous magnesium-fiber reinforced bone cement with enhanced mechanical and biological properties
- 11 March 2025
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 173, 214285
Open AccessBioresorbable, amorphous magnesium-fiber reinforced bone cement with enhanced mechanical and biological properties
- Open Access
- 1 February 2025
- Published by KEAI Publishing in Bioactive Materials
- Vol. 44, 501-515
In vivo performance of lean bioabsorbable Mg–Ca alloy X0 and comparison to WE43: Influence of surface modification and alloying content
Magnesium alloys present a compelling prospect for absorbable implant materials in orthopedic and trauma surgery. This study evaluates an ultra-high purity, lean magnesium-calcium alloy (X0), both with and without plasma electrolytic oxidation (PEO) surface modification, in comparison to a clinically utilized WE43 magnesium alloy. It is shown that the mechanical properties of X0 can be tuned to yield a high-strength material suitable for bone screws (with an ultimate tensile strength of 336 MPa) or a ductile material appropriate for intraoperatively deformable plates (with an elongation at fracture of 24 %). Four plate-screw combinations were implanted onto the pelvic bones of six sheep without osteotomy for 8 weeks. Subsequent analysis utilized histology, micro-computed tomography, and light and electron microscopy. All implants exhibited signs of degradation and hydrogen-gas evolution, with PEO-coated X0 implants demonstrating the least volume loss and the most substantial new-bone formation on the implant surface and surrounding cancellous bone. Furthermore, the osteoconductive properties of the X0 implants, when uncoated, exceeded those of the uncoated WE43 implants, as evidenced by greater new-bone formation on the surface. This osteoconductivity was amplified with PEO surface modification, which mitigated gas evolution and enhanced osseointegration, encouraging bone apposition in the cancellous bone vicinity. These findings thus indicate that PEO-coated X0 implants hold substantial promise as a biocompatible and absorbable implant material.
- 1 February 2025
- Published by KEAI Publishing in Bioactive Materials
- Vol. 44, 501-515
Open AccessIn vivo performance of lean bioabsorbable Mg–Ca alloy X0 and comparison to WE43: Influence of surface modification and alloying content
Magnesium alloys present a compelling prospect for absorbable implant materials in orthopedic and trauma surgery. This study evaluates an ultra-high purity, lean magnesium-calcium alloy (X0), both with and without plasma electrolytic oxidation (PEO) surface modification, in comparison to a clinically utilized WE43 magnesium alloy. It is shown that the mechanical properties of X0 can be tuned to yield a high-strength material suitable for bone screws (with an ultimate tensile strength of 336 MPa) or a ductile material appropriate for intraoperatively deformable plates (with an elongation at fracture of 24 %). Four plate-screw combinations were implanted onto the pelvic bones of six sheep without osteotomy for 8 weeks. Subsequent analysis utilized histology, micro-computed tomography, and light and electron microscopy. All implants exhibited signs of degradation and hydrogen-gas evolution, with PEO-coated X0 implants demonstrating the least volume loss and the most substantial new-bone formation on the implant surface and surrounding cancellous bone. Furthermore, the osteoconductive properties of the X0 implants, when uncoated, exceeded those of the uncoated WE43 implants, as evidenced by greater new-bone formation on the surface. This osteoconductivity was amplified with PEO surface modification, which mitigated gas evolution and enhanced osseointegration, encouraging bone apposition in the cancellous bone vicinity. These findings thus indicate that PEO-coated X0 implants hold substantial promise as a biocompatible and absorbable implant material.
- Open Access
- 1 January 2025
- Published by KEAI Publishing in Bioactive Materials
- Vol. 43, 603-618
Development of an implantable sensor system for in vivo strain, temperature, and pH monitoring: comparative evaluation of titanium and resorbable magnesium plates
Biodegradable magnesium is a highly desired material for fracture fixation implants because of its good mechanical properties and ability to completely dissolve in the body over time, eliminating the need for a secondary surgery to remove the implant. Despite extensive research on these materials, there remains a dearth of information regarding critical factors that affect implant performance in clinical applications, such as the in vivo pH and mechanical loading conditions. We developed a measurement system with implantable strain, temperature, pH and motion sensors to characterize magnesium and titanium plates, fixating bilateral zygomatic arch osteotomies in three Swiss alpine sheep for eight weeks. pH 1-2 mm above titanium plates was 6.6 +/- 0.4, while for magnesium plates it was slightly elevated to 7.4 +/- 0.8. Strains on magnesium plates were higher than on titanium plates, possibly due to the lower Young's modulus of magnesium. One magnesium plate experienced excessive loading, which led to plate failure within 31 h. This is, to our knowledge, the first in vivo strain, temperature, and pH data recorded for magnesium implants used for fracture fixation. These results provide insight into magnesium degradation and its influence on the in vivo environment, and may help to improve material and implant design for future clinical applications.
- 1 January 2025
- Published by KEAI Publishing in Bioactive Materials
- Vol. 43, 603-618
Open AccessDevelopment of an implantable sensor system for in vivo strain, temperature, and pH monitoring: comparative evaluation of titanium and resorbable magnesium plates
Biodegradable magnesium is a highly desired material for fracture fixation implants because of its good mechanical properties and ability to completely dissolve in the body over time, eliminating the need for a secondary surgery to remove the implant. Despite extensive research on these materials, there remains a dearth of information regarding critical factors that affect implant performance in clinical applications, such as the in vivo pH and mechanical loading conditions. We developed a measurement system with implantable strain, temperature, pH and motion sensors to characterize magnesium and titanium plates, fixating bilateral zygomatic arch osteotomies in three Swiss alpine sheep for eight weeks. pH 1-2 mm above titanium plates was 6.6 +/- 0.4, while for magnesium plates it was slightly elevated to 7.4 +/- 0.8. Strains on magnesium plates were higher than on titanium plates, possibly due to the lower Young's modulus of magnesium. One magnesium plate experienced excessive loading, which led to plate failure within 31 h. This is, to our knowledge, the first in vivo strain, temperature, and pH data recorded for magnesium implants used for fracture fixation. These results provide insight into magnesium degradation and its influence on the in vivo environment, and may help to improve material and implant design for future clinical applications.
- Open Access
- 31 July 2024
- Published by Elsevier in Acta Materialia
- Vol. 278
High-performance ultra-lean biodegradable Mg–Ca alloys and guidelines for their processing
- 31 July 2024
- Published by Elsevier in Acta Materialia
- Vol. 278
Open AccessHigh-performance ultra-lean biodegradable Mg–Ca alloys and guidelines for their processing