Hossein Afshari has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Machine Learning-Based High-Voltage Circuit Breaker Defect Classification Utilizing Savitzky–Golay Filter

    by Sajjad Asefi, Soheil Asefi, Hossein Afshari, Jako Kilter, Ebrahim Shayesteh, Patrik Hilber, Tommie Lindquist

    High-voltage circuit breakers (HVCBs) are critical components in power systems to maintain reliable operation. Accurate condition monitoring of HVCBs is vital to reduce maintenance costs and consequently to enhance the grid reliability. However, achieving this with low-cost measurement devices, which often provide noisy signals, poses a significant challenge. In this article, a novel defect classification framework for HVCBs is proposed that uses the Savitzky–Golay filter to preprocess the most common condition monitoring signal, which is the trip/close coil current. This filter is well-known for denoising while preserving critical signal features. Following signal preprocessing, a robust defect detection and classification methodology is introduced, combining time-series similarity assessment techniques, such as Euclidean distance and dynamic time warping (DTW), with machine learning (ML) algorithms. Moreover, an experimental setup is designed to emulate the behavior of an HVCB’s coil mechanism. To further enhance the model transparency, Shapley additive explanations (SHAP) analysis is applied, providing interpretability into feature contributions toward model decisions. The obtained results validate the effectiveness of the proposed hybrid approach, demonstrating its potential to provide a cost-effective, accurate, and reliable solution for HVCB condition monitoring.


  • Comprehensive Comparison of Grid-Connected Flyback-Based Microinverter With Primary and Secondary Side Decoupling Approach

    by Hossein Afshari, Oleksandr Husev, Oleksandr Matiushkin, Saeed Pourjafar, Naser Vosoughi Kurdkandi, Dmitri Vinnikov

    This paper compares grid-connected flyback-based microinverters employing primary and secondary side fundamental power ripple decoupling approaches. The passive decoupling techniques involve the use of the unfolding circuit on the primary side and an H-bridge inverter on the secondary side to achieve the same number of passive components. The unfolding circuit operates at the grid frequency, unfolding/folding the rectified sinusoidal waveform and providing a current pathway to the grid. Comparative assessments encompass energy accumulation in inductances and capacitors, conduction and switching losses, and voltage stress across semiconductors. Proportional Resonant controllers govern grid current. The theoretical evaluation is complemented by cost analysis using existing component prices, and experimental setups utilizing four-layer printed circuit boards for primary and secondary side decoupling. The results provide a comprehensive comparison, and conclusions offer valuable recommendations based on both theoretical and experimental insights.


  • Forward-Based DC-DC Converter With Eliminated Leakage Inductance Problem

    by Oleksandr Matiushkin, Oleksandr Husev, Hossein Afshari, Enrique Romero-Cadaval, Carlos Roncero-Clemente

    The novel forward-based converter for low-power solar applications is presented in this work. The proposed converter provides an efficient performance in a wide range of the input voltage with low component count. The proposed dc-dc topologies are advanced forward dc-dc converters with an additional clamped output capacitor. The idea of such a type of converter is to transfer magnetizing energy of transformer to the output side, instead of using an input clamp circuit. Two possible topologies are considered to cover this feature. The design guidelines of the passive component of the proposed solutions are discussed. The converter may work in continuous conduction mode and discontinuous conduction mode due to different levels of the input power. A comparison between proposed topologies is made and discussed. Experimental prototype of the proposed forward-based dc-dc converter along with experimental results of the dc grid connection system are presented. The parameters of commercial photovoltaic panels have been chosen to validate the maximum power point tracking based on Perturb and Observe algorithm. The efficiency of the proposed solution is studied and discussed.


  • Open Access

    Comprehensive Comparison of Isolated High Step-up DC-DC Converters for Low Power Application

    by Saeed Pourjafar, Hossein Afshari, Parham Mohseni, Oleksandr Husev, Oleksandr Matiushkin, Noman Shabbir

    In this paper comprehensive evaluations of isolated high step-up dc-dc topologies have been investigated. These converters are especially well suited for distributed generation systems utilizing renewable or alternative energy sources that need a wide input voltage range with load regulation. With this in mind, this work primarily concentrates on comparative analysis of various isolated configurations employed in possible industry applications. Consequently, several isolated structures, including flyback, forward, push-pull, and full bridge and other similar solutions have been carried out in the literature. For the purpose of comparative and theoretical analysis, some of the circuit parameters are considered, which include voltage conversion ratio, semiconductor element voltage stress, component size, and conduction and switching losses. Furthermore, the selected configurations have been discussed in terms of cost estimation and financial feasibility. In addition, the design procedure and experimental prototypes of the available solutions with the main results are presented. Derived from this investigation, the authors provide a guide to help researchers to identify different isolated topologies with wide input voltage range and galvanic isolation for prospective research directions within this area


  • Comparison of Grid-Connected Flyback-based Microinverter with Primary and Secondary Side Decoupling Approach

    by Hossein Afshari, Oleksandr Husev, Dmitri Vinnikov, Oleksandr Matiushkin, Naser Vosoughi Kurdkandi

    This paper presents a comparison between grid-connected flyback-based microinverter with primary and secondary side fundamental power ripple decoupling. The flyback converter is proposed to work in continuous conduction mode due to high-power capability. The unfolding circuit and H-bridge inverter are used as a primary side and secondary side decoupling methods. Unfolding circuit operates at the grid frequency, unfolds/folds the rectified sinusoidal waveform, and provides a current pathway to the grid. The comparison is done in terms of energy accumulated in inductances and capacitors, conduction and switching losses, voltage stress across semiconductors. The grid current is controlled through the Proportional Resonant controller. Finally, the simulation using PowerSim software is verifying the theoretical evaluation The spider diagram is used to show the comparison of both solutions. The recommendations are given in conclusions.