Khotimatul Fauziah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Khotimatul Fauziah has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Yuli Astriani
Nuclear Polytechnic of Indonesia, National Research and Innovation Agency (BRIN)
6 shared publicationsRiza
National Laboratory for Energy Conversion Technology BPPT, Serpong, Indonesia
4 shared publications- Amiral Aziz
Research Center for Conversion and Conservation Energy-National Research and Innovation, Agency Republic of Indonesia (BRIN), Indonesia
3 shared publications Asih Kurniasari
Research Center for Energy Conversion and Conservation, National Research and Innovation Agency (BRIN)
3 shared publications- Didik Rostyono
National Research and Innovation Agency
3 shared publications Dionysius A. Renata
National Laboratory for Energy Conversion Technology BPPT,Serpong,Indonesia
3 shared publications
Latest Publications
- Open Access
Design and Experimental Validation of a Cluster-Based Virtual Power Plant with Centralized Management System in Compliance with IEC Standard
As power systems decentralize, Virtual Power Plants (VPPs) offer a promising approach to coordinate distributed energy resources (DERs) and enhance grid flexibility. However, real-world validation of VPP performance in Indonesia remains limited, especially regarding internationally aligned test standards. This study presents the design and experimental validation of a cluster-based VPP framework integrated with a centralized VPP Management System (VMS). Each cluster integrates solar photovoltaic (PV) system, battery energy storage system (BESS), and controllable load. A Local Control Unit (LCU) manages cluster operations, while the VMS coordinates power export–import dispatch, cluster-level aggregation, and grid compliance. The framework proposes a scalable VPP architecture and presents the first comprehensive experimental verification of key VPP performance indicators, including response time, adjustment rate, and accuracy, in the Indonesian context. Testing was conducted in alignment with the IEC TS 63189-1:2023 international standard. Results suggest real time responsiveness and indicate that, even at smaller scales, VPPs may contribute effectively to voltage control while exhibiting minimal influence on system frequency in interconnected grids. These findings confirm the capability of the proposed VPP framework to provide reliable real time control, ancillary services, and aggregated energy management. Its cluster-based architecture supports scalability for broader deployment in complex grid environments.
Open AccessDesign and Experimental Validation of a Cluster-Based Virtual Power Plant with Centralized Management System in Compliance with IEC Standard
As power systems decentralize, Virtual Power Plants (VPPs) offer a promising approach to coordinate distributed energy resources (DERs) and enhance grid flexibility. However, real-world validation of VPP performance in Indonesia remains limited, especially regarding internationally aligned test standards. This study presents the design and experimental validation of a cluster-based VPP framework integrated with a centralized VPP Management System (VMS). Each cluster integrates solar photovoltaic (PV) system, battery energy storage system (BESS), and controllable load. A Local Control Unit (LCU) manages cluster operations, while the VMS coordinates power export–import dispatch, cluster-level aggregation, and grid compliance. The framework proposes a scalable VPP architecture and presents the first comprehensive experimental verification of key VPP performance indicators, including response time, adjustment rate, and accuracy, in the Indonesian context. Testing was conducted in alignment with the IEC TS 63189-1:2023 international standard. Results suggest real time responsiveness and indicate that, even at smaller scales, VPPs may contribute effectively to voltage control while exhibiting minimal influence on system frequency in interconnected grids. These findings confirm the capability of the proposed VPP framework to provide reliable real time control, ancillary services, and aggregated energy management. Its cluster-based architecture supports scalability for broader deployment in complex grid environments.
- 5 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 138, 1279-1292
A comprehensive analysis of wind power integrated with solar and hydrogen storage systems: Case study of Java's Southern coast
- 5 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 138, 1279-1292
A comprehensive analysis of wind power integrated with solar and hydrogen storage systems: Case study of Java's Southern coast
- Open Access
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (5) , 4940-4955
Wind-powered water pumping system for corn plantations under the food estate program on Sumba Island, Indonesia
The Food and Agriculture Organization (FAO) released a communiqué in March 2020 cautioning about the possibility of a worldwide food emergency due to coronavirus disease (COVID-19). As a response to the food shortages brought on by the COVID-19 outbreak, the authorities of Indonesia initiated a nationwide program aimed at improving the country's food supply known as the food estate (FE), which was later incorporated into national strategic programs. The climate and availability of surface water sources in this region make establishing an FE area in the Central Sumba Regency difficult. Sumba, on the other hand, possesses wind energy resources that can be transformed into electrical energy and used to pump underground water for agricultural purposes. A wind-powered water pump (WPW) is being developed in this study to provide water for maize plantations in the FE region in Central Sumba District, Indonesia. The study on the levelized cost of energy (LCOE) for water pumping indicates that the wind-powered system is more economically viable than the diesel-powered alternative. The LCOE for a WPW pumping system is 6,994 IDR/kWh, whereas the LCOE for a diesel-powered system is 16,667 IDR/kWh. The overall net present value of WPW and diesel-powered systems is 708,667,200 IDR and 2,158,349,000 IDR, respectively. This study contributes significantly to informed decision-making for enhancing the performance viability of the wind water pumping system for the food estate program in Indonesia.
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (5) , 4940-4955
Open AccessWind-powered water pumping system for corn plantations under the food estate program on Sumba Island, Indonesia
The Food and Agriculture Organization (FAO) released a communiqué in March 2020 cautioning about the possibility of a worldwide food emergency due to coronavirus disease (COVID-19). As a response to the food shortages brought on by the COVID-19 outbreak, the authorities of Indonesia initiated a nationwide program aimed at improving the country's food supply known as the food estate (FE), which was later incorporated into national strategic programs. The climate and availability of surface water sources in this region make establishing an FE area in the Central Sumba Regency difficult. Sumba, on the other hand, possesses wind energy resources that can be transformed into electrical energy and used to pump underground water for agricultural purposes. A wind-powered water pump (WPW) is being developed in this study to provide water for maize plantations in the FE region in Central Sumba District, Indonesia. The study on the levelized cost of energy (LCOE) for water pumping indicates that the wind-powered system is more economically viable than the diesel-powered alternative. The LCOE for a WPW pumping system is 6,994 IDR/kWh, whereas the LCOE for a diesel-powered system is 16,667 IDR/kWh. The overall net present value of WPW and diesel-powered systems is 708,667,200 IDR and 2,158,349,000 IDR, respectively. This study contributes significantly to informed decision-making for enhancing the performance viability of the wind water pumping system for the food estate program in Indonesia.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3069 (1) , 020126
Development of insulation test system on DC electric vehicle charging station
Insulation detection is one of the important steps in the electric vehicle (EV) charging process to ensure the energy is transferred safely and minimize the ris Insulation detection is one of the important steps in the electric vehicle (EV) charging process to ensure the energy is transferred safely and minimize the ris
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3069 (1) , 020126
Development of insulation test system on DC electric vehicle charging station
Insulation detection is one of the important steps in the electric vehicle (EV) charging process to ensure the energy is transferred safely and minimize the ris Insulation detection is one of the important steps in the electric vehicle (EV) charging process to ensure the energy is transferred safely and minimize the ris
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1916-1927
Performance Analysis and Comparison of a 93.6 kW Grid-Connected Rooftop Photovoltaic System in South Tangerang
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1916-1927
Performance Analysis and Comparison of a 93.6 kW Grid-Connected Rooftop Photovoltaic System in South Tangerang
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1982-1990
Performance Test of 1 kW PEM Fuel Cell System to Determine Its Empirical Model
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1982-1990
Performance Test of 1 kW PEM Fuel Cell System to Determine Its Empirical Model
- Open Access
- 1 January 2023
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 13 (V32i3) , 1351-1363
Optimizing Turbine Siting and Wind Farm Layout in Indonesia
Wind resource assessments are required to identify a specific area capable of producing valuable energy from wind speeds. This paper aims to optimize wind assessment through wind farm siting and layout in Indonesia’s semi-arid region. Wind data collected on Sumba Island over a one-year period was analyzed to assess the area's wind energy potential. Wind Atlas Analysis and Application Programme (WAsP) and Windographer were used to generate a generalized wind climate and resource maps for the area. Wind farm layout and preliminary turbine micro-sitting were completed with various scenarios in mind to achieve the best possible result. Four different scenarios are considered to maximize power output. There are 34 identical wind turbines with a unit capacity of 90 kW in Scenario 1. Scenario 2 includes 20 identical wind turbines with a total capacity of 3000 kW. In Scenario 3, 14 identical wind turbines with 225 kW of unit capacity are used. There are 12 identical wind turbines with a unit capacity of 250 kW in Scenario 4. The results showed that scenario 1 produced the highest total net Annual Energy Production (AEP) of 11,287 MWh/year with a 3.73 % wake loss. The minimum wake loss seemed to be 2.62 % in scenario 4, with a total net AEP of 10,22MWh/year.
- 1 January 2023
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 13 (V32i3) , 1351-1363
Open AccessOptimizing Turbine Siting and Wind Farm Layout in Indonesia
Wind resource assessments are required to identify a specific area capable of producing valuable energy from wind speeds. This paper aims to optimize wind assessment through wind farm siting and layout in Indonesia’s semi-arid region. Wind data collected on Sumba Island over a one-year period was analyzed to assess the area's wind energy potential. Wind Atlas Analysis and Application Programme (WAsP) and Windographer were used to generate a generalized wind climate and resource maps for the area. Wind farm layout and preliminary turbine micro-sitting were completed with various scenarios in mind to achieve the best possible result. Four different scenarios are considered to maximize power output. There are 34 identical wind turbines with a unit capacity of 90 kW in Scenario 1. Scenario 2 includes 20 identical wind turbines with a total capacity of 3000 kW. In Scenario 3, 14 identical wind turbines with 225 kW of unit capacity are used. There are 12 identical wind turbines with a unit capacity of 250 kW in Scenario 4. The results showed that scenario 1 produced the highest total net Annual Energy Production (AEP) of 11,287 MWh/year with a 3.73 % wake loss. The minimum wake loss seemed to be 2.62 % in scenario 4, with a total net AEP of 10,22MWh/year.
- 23 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling of Electric Vehicle Charging Energy Consumption using Machine Learning
Several electric vehicle charging station infrastructures (EVCS) have been built in Indonesia, both private and public. A centralized management system is required to manage several charging stations. The central system uses collected historical charging transaction data to analyze patterns of EVCS energy consumption. A supervised machine learning model is applied to forecast the charging station (CS) energy consumption for the next day based on the daily transaction of the previous days. Weather condition data are also applied as additional parameters to determine their effect on charging energy consumption. Four machine learning algorithms have been evaluated, including Random Forest (RF), Support Vector Regression (SVR), XGBoost, and Multilayer Perceptron (MLP). MLP obtained the best accuracy value with an R 2 score of 0.85 and RMSE of 115.17 for the model without the weather variables. Meanwhile, SVR outperforms all models using a dataset with weather variables. Overall, MLP and SVR can perform well on both types of datasets. This result is expected to be used as a reference method for energy consumption prediction in the electric vehicle charging infrastructure in Indonesia.
- 23 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modeling of Electric Vehicle Charging Energy Consumption using Machine Learning
Several electric vehicle charging station infrastructures (EVCS) have been built in Indonesia, both private and public. A centralized management system is required to manage several charging stations. The central system uses collected historical charging transaction data to analyze patterns of EVCS energy consumption. A supervised machine learning model is applied to forecast the charging station (CS) energy consumption for the next day based on the daily transaction of the previous days. Weather condition data are also applied as additional parameters to determine their effect on charging energy consumption. Four machine learning algorithms have been evaluated, including Random Forest (RF), Support Vector Regression (SVR), XGBoost, and Multilayer Perceptron (MLP). MLP obtained the best accuracy value with an R 2 score of 0.85 and RMSE of 115.17 for the model without the weather variables. Meanwhile, SVR outperforms all models using a dataset with weather variables. Overall, MLP and SVR can perform well on both types of datasets. This result is expected to be used as a reference method for energy consumption prediction in the electric vehicle charging infrastructure in Indonesia.
- 5 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 102-107
Design A Low-cost PV Performance Ratio Data Monitoring
Photovoltaic (PV) system’s performance ratio (PR) is used to measure the quality and performance of a PV system. The PR trend can be used to analyze whether a problem occurs in the system. With the advanced development of information and communication technology; nowadays, it is possible to build a real-time PR monitoring system. This paper explicates the design process of a low-cost PV plant’s data monitoring and its PR calculation using free open-access applications whilst following the guidelines on the International Standard IEC 61724. The in-plane solar irradiation and inverter’s daily AC yield energy data are retrieved using Node-red application and are stored in an MySQL database. Using MySQL query commands, the PR values are calculated from the measured data which then are displayed to a web-based application that is programmed using the Grafana application. In this paper, the considered PV system is a 10600 W PV rooftop with a 10kW grid-tied inverter.
- 5 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 102-107
Design A Low-cost PV Performance Ratio Data Monitoring
Photovoltaic (PV) system’s performance ratio (PR) is used to measure the quality and performance of a PV system. The PR trend can be used to analyze whether a problem occurs in the system. With the advanced development of information and communication technology; nowadays, it is possible to build a real-time PR monitoring system. This paper explicates the design process of a low-cost PV plant’s data monitoring and its PR calculation using free open-access applications whilst following the guidelines on the International Standard IEC 61724. The in-plane solar irradiation and inverter’s daily AC yield energy data are retrieved using Node-red application and are stored in an MySQL database. Using MySQL query commands, the PR values are calculated from the measured data which then are displayed to a web-based application that is programmed using the Grafana application. In this paper, the considered PV system is a 10600 W PV rooftop with a 10kW grid-tied inverter.
- 5 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 425-430
Design of AC Electric Vehicle Supply Equipment based on Safety Standard
Electric vehicle supply equipment (EVSE) is a battery charging system for electric vehicles (EVs). EVSE must be designed to refer to the applicable standards to ensure security and interoperability with various types of EV. This paper explains the design of EVSE for mode 3 AC charging station (CS) based on International standard IEC 61851-1. The design follows the safety requirements on IEC 61851-1, such as overvoltage, overcurrent, and residual current devices to protect persons against electric shocks. Moreover, the charge controller manages the functionality of the devices and their communication so that energy transfers safely. The EVSE is equipped with a human-machine interface (HMI) using Raspberry Pi as the central processor to communicate between CS and EV users. The open charge point protocol (OCPP) is installed for communication between CS and the back-end system; thus, CS can be monitored and managed from the central system. The design is implemented for a 22 kW 3-phase AC EVSE and its testing result demonstrated a successful charging process to the commercial EV, Mitsubishi i-MiEV.
- 5 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 425-430
Design of AC Electric Vehicle Supply Equipment based on Safety Standard
Electric vehicle supply equipment (EVSE) is a battery charging system for electric vehicles (EVs). EVSE must be designed to refer to the applicable standards to ensure security and interoperability with various types of EV. This paper explains the design of EVSE for mode 3 AC charging station (CS) based on International standard IEC 61851-1. The design follows the safety requirements on IEC 61851-1, such as overvoltage, overcurrent, and residual current devices to protect persons against electric shocks. Moreover, the charge controller manages the functionality of the devices and their communication so that energy transfers safely. The EVSE is equipped with a human-machine interface (HMI) using Raspberry Pi as the central processor to communicate between CS and EV users. The open charge point protocol (OCPP) is installed for communication between CS and the back-end system; thus, CS can be monitored and managed from the central system. The design is implemented for a 22 kW 3-phase AC EVSE and its testing result demonstrated a successful charging process to the commercial EV, Mitsubishi i-MiEV.