F. Leonetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
F. Leonetti has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro M. Baldini
INFN Sezione di Pisa, Largo Bruno Pontecorvo, 3, 56127, Pisa, Italy
4 shared publications - Antoine Venturini
INFN Sezione di Pisa, Largo Bruno Pontecorvo, 3, 56127, Pisa, Italy
4 shared publications - Fabrizio Cei
INFN Sezione di Pisa, Largo Bruno Pontecorvo, 3, 56127, Pisa, Italy
4 shared publications - L. Bianco
INFN Sezione di Pisa, Largo Bruno Pontecorvo, 3, 56127, Pisa, Italy
4 shared publications - Luca Galli
INFN Sezione di Pisa, Largo Bruno Pontecorvo, 3, 56127, Pisa, Italy
4 shared publications - Marco Chiappini
INFN Sezione di Pisa, Largo Bruno Pontecorvo, 3, 56127, Pisa, Italy
4 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03052
The use of O 2 in gas mixtures for drift chambers
The use of Oxygen in gas mixtures for drift chambers is highly discouraged because Oxygen, being strongly electronegative, is generally believed to lead, even in very small quantities, to extremely reduced drift electron survival probability, thus preventing the detector's operation. The drift chamber of the MEG II experiment at PSI has been operating for several years with a gas mixture that mainly contains He:Isobutane in relative proportions of 90:10 % by molar concentration, in addition to 1.5% Isopropanol and 0.5% Oxygen. Oxygen and Isopropanol are essential for the proper functioning of the chamber. The electron attachment in the mixture used has proven negligible for the proper operation of the chamber and agrees well with the Garfield++ simulation after correctly accounting for the three-body attachment simulation. However, it is important to note that, in the case of ternary or quaternary mixtures (as in the case of MEG II), it is not possible to provide Garfield++ with just the ingredients of the mixture used to obtain correct attachment values. Instead, the code needs to be properly modified and recompiled.
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03052
Open AccessThe use of O 2 in gas mixtures for drift chambers
The use of Oxygen in gas mixtures for drift chambers is highly discouraged because Oxygen, being strongly electronegative, is generally believed to lead, even in very small quantities, to extremely reduced drift electron survival probability, thus preventing the detector's operation. The drift chamber of the MEG II experiment at PSI has been operating for several years with a gas mixture that mainly contains He:Isobutane in relative proportions of 90:10 % by molar concentration, in addition to 1.5% Isopropanol and 0.5% Oxygen. Oxygen and Isopropanol are essential for the proper functioning of the chamber. The electron attachment in the mixture used has proven negligible for the proper operation of the chamber and agrees well with the Garfield++ simulation after correctly accounting for the three-body attachment simulation. However, it is important to note that, in the case of ternary or quaternary mixtures (as in the case of MEG II), it is not possible to provide Garfield++ with just the ingredients of the mixture used to obtain correct attachment values. Instead, the code needs to be properly modified and recompiled.
- Open Access
- 6 June 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (6) , 1-29
A compact frozen-spin trap for the search for the electric dipole moment of the muon
Electric dipole moments (EDM) of fundamental particles inherently violate time-reversal (T) and the combined charge-conjugation and parity symmetry (CP). We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, $$E\approx {165\,\mathrm{MV/m}}$$ , experienced in the rest frame of the muon with a momentum of about $${23\,\mathrm{MeV/}}c$$ when it passes through a solenoidal magnetic field of $$|\vec {B}|={2.5\,\textrm{T}}$$ . In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is $$\sigma (d)\le {4E-21\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ . In a subsequent phase, Phase II, we propose to improve the sensitivity to $$\sigma (d)\le {6E-23\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ using a dedicated instrument installed on a different beamline that produces muons of momentum 125 $$\textrm{MeV}\!/\!{ c}$$ .- 6 June 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (6) , 1-29
Open AccessA compact frozen-spin trap for the search for the electric dipole moment of the muon
Electric dipole moments (EDM) of fundamental particles inherently violate time-reversal (T) and the combined charge-conjugation and parity symmetry (CP). We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, $$E\approx {165\,\mathrm{MV/m}}$$ , experienced in the rest frame of the muon with a momentum of about $${23\,\mathrm{MeV/}}c$$ when it passes through a solenoidal magnetic field of $$|\vec {B}|={2.5\,\textrm{T}}$$ . In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is $$\sigma (d)\le {4E-21\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ . In a subsequent phase, Phase II, we propose to improve the sensitivity to $$\sigma (d)\le {6E-23\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ using a dedicated instrument installed on a different beamline that produces muons of momentum 125 $$\textrm{MeV}\!/\!{ c}$$ . - Open Access
- 8 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1067
Bayesian tuning of the Compact Muon Beam Line for the Mu3e experiment
- 8 August 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1067
Open AccessBayesian tuning of the Compact Muon Beam Line for the Mu3e experiment