Alexander Diaz-Chyla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander Diaz-Chyla has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Andreas Förster
European Southern Observatory (Germany)
1 shared publication- Antonio Pedrero
Grupo de Investigación en Acústica Arquitectónica, Universidad Politécnica de Madrid, CP: 28040 Madrid, Spain
1 shared publication Borja Vega
IDOM (Spain)
1 shared publicationCarles Pizarro
Univ. Politècnica de Catalunya (Spain)
1 shared publication- Daniel de la Prida
Universidad Politecnica de Madrid, Madrid, Spain
1 shared publication David Caballol
1 shared publication
Latest Publications
- Open Access
- 29 May 2026
- Published by Elsevier in Building and Environment
- Vol. 301
Comparative laboratory analysis of window sound insulation across glazing types in the 50–5000 Hz range: Evaluation of different low-frequency methods
- 29 May 2026
- Published by Elsevier in Building and Environment
- Vol. 301
Open AccessComparative laboratory analysis of window sound insulation across glazing types in the 50–5000 Hz range: Evaluation of different low-frequency methods
- 28 June 2024
- Published by IGI Global Scientific Publishing
- p. 350-379
The Compatibility of Thermal and Acoustic Insulation in the Façades External Renovation in Residential Buildings
In recent years, a significant economic effort has been made in the refurbishment and energy improvement of buildings, which should be used to improve their acoustics performance. It is necessary to avoid energy improvement from deteriorating the pre-existing acoustic performance prior to the refurbishment. In this work, an analysis of the acoustic insulation of the façades of enclosures in residential buildings is carried out in which the thermal insulation of the blind part of the façade is improved on the outside without mullions and battens. The most important factor for the improvement of the airborne sound insulation of the blind side of the façade is that the dynamic stiffness of the external thermal cladding is as low as possible, and that the openings are solved with a double asymmetrical glazing and its air cavity is as thick as possible. The obtained results may be useful for all professionals involved in the construction process of building renovation: architects, engineers, developers, manufacturers, etc.
- 28 June 2024
- Published by IGI Global Scientific Publishing
- p. 350-379
The Compatibility of Thermal and Acoustic Insulation in the Façades External Renovation in Residential Buildings
In recent years, a significant economic effort has been made in the refurbishment and energy improvement of buildings, which should be used to improve their acoustics performance. It is necessary to avoid energy improvement from deteriorating the pre-existing acoustic performance prior to the refurbishment. In this work, an analysis of the acoustic insulation of the façades of enclosures in residential buildings is carried out in which the thermal insulation of the blind part of the façade is improved on the outside without mullions and battens. The most important factor for the improvement of the airborne sound insulation of the blind side of the façade is that the dynamic stiffness of the external thermal cladding is as low as possible, and that the openings are solved with a double asymmetrical glazing and its air cavity is as thick as possible. The obtained results may be useful for all professionals involved in the construction process of building renovation: architects, engineers, developers, manufacturers, etc.
- 26 August 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12182, 40-53
The Extremely Large Telescope (ELT) M1 Local Coherencer to phase mirror segments
The ELT M1 Local Coherencer is a non-contact metrology system aimed to simultaneously measure the relative pistons on the six sides of a target M1 segment with respect to neighboring ones (reference segments) with an accuracy below 300nm in a range of ±250μm. This measurement shall be performed while the Local Coherencer is supported by the M1 Segment Manipulator hanging from the M1 Segment Crane. IDOM has developed for the M1 Local Coherencer a lean, compact and robust solution featuring: - Six lightweight and compact Sensing Modules whose main system is a partially coherent light interferometer for the piston measurements that hugely simplifies image processing and avoids any ambiguity in the measurements. - Comprehensive and robust alignment detection and alignment compensation systems that ensure proper positioning and prevent apparent (bias) piston measurement errors. - A lean embodiment in which all the subsystems, including control and safety elements, are mounted on a single support structure and enclosed in the specified design volume, with no need to use the space reserved in the M1 Segment Manipulator - A solution largely based on small COTS and simple electronics, which account for ease of use, high reliability, easy replaceability and high durability of the system. This paper describes the proposed design as presented in the Preliminary Design Review (PDR) of the system held in May 2022.
- 26 August 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12182, 40-53
The Extremely Large Telescope (ELT) M1 Local Coherencer to phase mirror segments
The ELT M1 Local Coherencer is a non-contact metrology system aimed to simultaneously measure the relative pistons on the six sides of a target M1 segment with respect to neighboring ones (reference segments) with an accuracy below 300nm in a range of ±250μm. This measurement shall be performed while the Local Coherencer is supported by the M1 Segment Manipulator hanging from the M1 Segment Crane. IDOM has developed for the M1 Local Coherencer a lean, compact and robust solution featuring: - Six lightweight and compact Sensing Modules whose main system is a partially coherent light interferometer for the piston measurements that hugely simplifies image processing and avoids any ambiguity in the measurements. - Comprehensive and robust alignment detection and alignment compensation systems that ensure proper positioning and prevent apparent (bias) piston measurement errors. - A lean embodiment in which all the subsystems, including control and safety elements, are mounted on a single support structure and enclosed in the specified design volume, with no need to use the space reserved in the M1 Segment Manipulator - A solution largely based on small COTS and simple electronics, which account for ease of use, high reliability, easy replaceability and high durability of the system. This paper describes the proposed design as presented in the Preliminary Design Review (PDR) of the system held in May 2022.