Bo Liu
Bo Liu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Shilun Feng
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, CHINA
7 shared publications - Fangzhou Zhang
Xiangfu Laboratory, Jiashan 314100, China
3 shared publications Jianlong Zhao
Xiangfu Laboratory, Jiashan, 314100, China; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Tech-nology, Chinese Academy of Sciences, Shanghai, 200050, China; School of Microelectronics, Shanghai University, Shanghai, 2018004, China; Shanghai Frontier Innovation Research Institute, Shanghai, 201108, China
3 shared publications- Jianxin Cheng
Xiangfu Laboratory, Jiashan, 314100, China; State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Tech-nology, Chinese Academy of Sciences, Shanghai, 200050, China
3 shared publications Chang Chen
School of Microelectronics, Shanghai University, Shanghai, 2018004, China; Institute of Medical Chip, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
2 shared publications- Jianlong Zhao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 14 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (5) , 599
Portable and Point-of-Care Testing Approach for Determining Soil Extracellular Enzyme Activities
Soil eco-enzymes (i.e., microbial extracellular enzymes) play essential roles in terrestrial nutrient cycling and support ecosystem services. In this regard, their activities serve as indicators of soil health. However, conventional spectrophotometric and microplate fluorometric assays are often limited by lengthy reaction procedures, relatively high reagent consumption, and insufficient compatibility with complex soil matrices. In this investigation, we developed a portable, centrifugally driven microfluidic chip for the rapid and sensitive determination of multiple soil extracellular enzyme activities. This integrated platform automated sample aliquoting, reagent metering, mixing, and sedimentation, enabling the parallel measurement of eight enzymes. Such system demonstrated precise liquid control via capillary valves and high optical uniformity ( 0.99) across diverse soil types. Compared with conventional microplate assays, the microfluidic method improved reproducibility (CV < 15%), enhanced the detection of weak fluorescence signals, and increased throughput while reducing reagent consumption. This field-ready platform provides a robust solution for standardized soil enzyme assessment and offers future potential for integration with AI-driven data analytics and large-scale ecological monitoring frameworks.
- 14 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (5) , 599
Open AccessPortable and Point-of-Care Testing Approach for Determining Soil Extracellular Enzyme Activities
Soil eco-enzymes (i.e., microbial extracellular enzymes) play essential roles in terrestrial nutrient cycling and support ecosystem services. In this regard, their activities serve as indicators of soil health. However, conventional spectrophotometric and microplate fluorometric assays are often limited by lengthy reaction procedures, relatively high reagent consumption, and insufficient compatibility with complex soil matrices. In this investigation, we developed a portable, centrifugally driven microfluidic chip for the rapid and sensitive determination of multiple soil extracellular enzyme activities. This integrated platform automated sample aliquoting, reagent metering, mixing, and sedimentation, enabling the parallel measurement of eight enzymes. Such system demonstrated precise liquid control via capillary valves and high optical uniformity ( 0.99) across diverse soil types. Compared with conventional microplate assays, the microfluidic method improved reproducibility (CV < 15%), enhanced the detection of weak fluorescence signals, and increased throughput while reducing reagent consumption. This field-ready platform provides a robust solution for standardized soil enzyme assessment and offers future potential for integration with AI-driven data analytics and large-scale ecological monitoring frameworks.
- 14 February 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1398, 345227
High-thermal-conductivity integrated EWOD chip for ultra-fast, low-cost pathogen detection
- 14 February 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1398, 345227
High-thermal-conductivity integrated EWOD chip for ultra-fast, low-cost pathogen detection
- Open Access
- 1 February 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (2) , 89
Nanozyme-Based Colorimetric Assay on a Magnetic Microfluidic Platform for Integrated Detection of TTX
Tetrodotoxin (TTX) is a potent marine neurotoxin, necessitating sensitive and user-friendly on-site assays. To address long workflows of traditional immunoassays and limited signal amplification in colorimetric microfluidics, we developed a nanozyme-catalyzed colorimetric magnetic microfluidic immunosensor (Nano-CMI). This platform combines an aptamer–antibody sandwich capture format with catalytic amplification via AuNR@Pt@m-SiO2 (APMS) nanozymes on a magnetically actuated microfluidic chip. Magnetic actuation simplifies sample handling and washing, while APMS catalysis enhances sensitivity and visual readout. The Nano-CMI has been used for the detection of TTX samples ranging from 0.2 to 20 ng/mL with a detection limit of 0.2 ng/mL in 10 min, following the linear equation: y = −31.14ln x + 110.15, and the entire “capture-reaction-detection” workflow can be completed within 1 h. With rapid response, minimal hands-on time, and robust performance, this platform offers a practical, high-sensitivity solution for on-site TTX screening in food safety and customs inspection.
- 1 February 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (2) , 89
Open AccessNanozyme-Based Colorimetric Assay on a Magnetic Microfluidic Platform for Integrated Detection of TTX
Tetrodotoxin (TTX) is a potent marine neurotoxin, necessitating sensitive and user-friendly on-site assays. To address long workflows of traditional immunoassays and limited signal amplification in colorimetric microfluidics, we developed a nanozyme-catalyzed colorimetric magnetic microfluidic immunosensor (Nano-CMI). This platform combines an aptamer–antibody sandwich capture format with catalytic amplification via AuNR@Pt@m-SiO2 (APMS) nanozymes on a magnetically actuated microfluidic chip. Magnetic actuation simplifies sample handling and washing, while APMS catalysis enhances sensitivity and visual readout. The Nano-CMI has been used for the detection of TTX samples ranging from 0.2 to 20 ng/mL with a detection limit of 0.2 ng/mL in 10 min, following the linear equation: y = −31.14ln x + 110.15, and the entire “capture-reaction-detection” workflow can be completed within 1 h. With rapid response, minimal hands-on time, and robust performance, this platform offers a practical, high-sensitivity solution for on-site TTX screening in food safety and customs inspection.
- Open Access
- 14 April 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 462
Recent Advances in Microfluidics-Based Monitoring of Waterborne Pathogens: From Isolation to Detection
Waterborne pathogens seriously threaten human life and can cause diarrhea, gastrointestinal disorders, and more serious systemic infections. These pathogens are usually caused by contaminated water sources that contain disease-causing microorganisms, such as bacteria, viruses, and parasites, which cause infection and disease when they enter the human body through drinking water or other means. Due to the wide range of transmission routes and the high potential risk of waterborne pathogens, there is an urgent need for an ultrasensitive, rapid, and specific pathogenic microorganism monitoring platform to meet the critical monitoring needs of some water bodies’ collection points daily monitoring needs. Microfluidics-based pathogen surveillance methods are an important stage towards automated detection through real-time and multi-targeted monitoring, thus enabling a comprehensive assessment of the risk of exposure to waterborne pathogens and even emerging microbial contaminants, and thus better protection of public health. Therefore, this paper reviews the latest research results on the isolation and detection of waterborne pathogens based on microfluidic methods. First, we introduce the traditional methods for isolation and detection of pathogens. Then, we compare some existing microfluidic pathogen isolation and detection methods and finally look forward to some future research directions and applications of microfluidic technology in waterborne pathogens monitoring.
- 14 April 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (4) , 462
Open AccessRecent Advances in Microfluidics-Based Monitoring of Waterborne Pathogens: From Isolation to Detection
Waterborne pathogens seriously threaten human life and can cause diarrhea, gastrointestinal disorders, and more serious systemic infections. These pathogens are usually caused by contaminated water sources that contain disease-causing microorganisms, such as bacteria, viruses, and parasites, which cause infection and disease when they enter the human body through drinking water or other means. Due to the wide range of transmission routes and the high potential risk of waterborne pathogens, there is an urgent need for an ultrasensitive, rapid, and specific pathogenic microorganism monitoring platform to meet the critical monitoring needs of some water bodies’ collection points daily monitoring needs. Microfluidics-based pathogen surveillance methods are an important stage towards automated detection through real-time and multi-targeted monitoring, thus enabling a comprehensive assessment of the risk of exposure to waterborne pathogens and even emerging microbial contaminants, and thus better protection of public health. Therefore, this paper reviews the latest research results on the isolation and detection of waterborne pathogens based on microfluidic methods. First, we introduce the traditional methods for isolation and detection of pathogens. Then, we compare some existing microfluidic pathogen isolation and detection methods and finally look forward to some future research directions and applications of microfluidic technology in waterborne pathogens monitoring.
- Open Access
- 6 August 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 379
Implementation of Rapid Nucleic Acid Amplification Based on the Super Large Thermoelectric Cooler Rapid Temperature Rise and Fall Heating Module
In the rapid development of molecular biology, nucleic acid amplification detection technology has received more and more attention. The traditional polymerase chain reaction (PCR) instrument has poor refrigeration performance during its transition from a high temperature to a low temperature in the temperature cycle, resulting in a longer PCR amplification cycle. Peltier element equipped with both heating and cooling functions was used, while the robust adaptive fuzzy proportional integral derivative (PID) algorithm was also utilized as the fundamental temperature control mechanism. The heating and cooling functions were switched through the state machine mode, and the PCR temperature control module was designed to achieve rapid temperature change. Cycle temperature test results showed that the fuzzy PID control algorithm was used to accurately control the temperature and achieve rapid temperature rise and fall (average rising speed = 11 °C/s, average falling speed = 8 °C/s) while preventing temperature overcharging, maintaining temperature stability, and achieving ultra-fast PCR amplification processes (45 temperature cycle time < 19 min). The quantitative results show that different amounts of fluorescence signals can be observed according to the different concentrations of added viral particles, and an analytical detection limit (LoD) as low as 10 copies per μL can be achieved with no false positive in the negative control. The results show that the TEC amplification of nucleic acid has a high detection rate, sensitivity, and stability. This study intended to solve the problem where the existing thermal cycle temperature control technology finds it difficult to meet various new development requirements, such as the rapid, efficient, and miniaturization of PCR.
- 6 August 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 379
Open AccessImplementation of Rapid Nucleic Acid Amplification Based on the Super Large Thermoelectric Cooler Rapid Temperature Rise and Fall Heating Module
In the rapid development of molecular biology, nucleic acid amplification detection technology has received more and more attention. The traditional polymerase chain reaction (PCR) instrument has poor refrigeration performance during its transition from a high temperature to a low temperature in the temperature cycle, resulting in a longer PCR amplification cycle. Peltier element equipped with both heating and cooling functions was used, while the robust adaptive fuzzy proportional integral derivative (PID) algorithm was also utilized as the fundamental temperature control mechanism. The heating and cooling functions were switched through the state machine mode, and the PCR temperature control module was designed to achieve rapid temperature change. Cycle temperature test results showed that the fuzzy PID control algorithm was used to accurately control the temperature and achieve rapid temperature rise and fall (average rising speed = 11 °C/s, average falling speed = 8 °C/s) while preventing temperature overcharging, maintaining temperature stability, and achieving ultra-fast PCR amplification processes (45 temperature cycle time < 19 min). The quantitative results show that different amounts of fluorescence signals can be observed according to the different concentrations of added viral particles, and an analytical detection limit (LoD) as low as 10 copies per μL can be achieved with no false positive in the negative control. The results show that the TEC amplification of nucleic acid has a high detection rate, sensitivity, and stability. This study intended to solve the problem where the existing thermal cycle temperature control technology finds it difficult to meet various new development requirements, such as the rapid, efficient, and miniaturization of PCR.