Gian Guyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gian Guyer has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Michael K. Fix
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland, Freiburgstrasse 18, Bern, 3010, Switzerland
7 shared publications - Silvan Mueller
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
6 shared publications - Peter Manser
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland, Freiburgstrasse 18, Bern, 3010, Switzerland
5 shared publications D.M. Aebersold
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, SWITZERLAND
3 shared publicationsH.A. Loebner
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, SWITZERLAND
3 shared publicationsJ. Bertholet
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, SWITZERLAND
3 shared publications
Latest Publications
- Open Access
- 31 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 221, 111414
A phase I dose escalation of FLASH radiotherapy in patients with cutaneous metastases from melanoma: The IMPulse trial
- 31 January 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 221, 111414
Open AccessA phase I dose escalation of FLASH radiotherapy in patients with cutaneous metastases from melanoma: The IMPulse trial
- Open Access
- 23 July 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 54, 101023
Lattice radiotherapy for extensive liver metastases in synchronous EGFR-mutant lung adenocarcinoma and small cell lung cancer
- 23 July 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 54, 101023
Open AccessLattice radiotherapy for extensive liver metastases in synchronous EGFR-mutant lung adenocarcinoma and small cell lung cancer
- Open Access
- 26 October 2024
- Published by Wiley in Medical Physics
- Vol. 52 (1) , 489-503
Dosimetric optimization for dynamic mixed beam arc therapy (DYMBARC)
Background: Non‐coplanarity and mixed beam modality could be combined to further enhance dosimetric treatment plan quality. We introduce dynamic mixed beam arc therapy (DYMBARC) as an innovative technique that combines non‐coplanar photon and electron arcs, dynamic gantry and collimator rotations, and intensity modulation with photon multileaf collimator (MLC). However, finding favorable beam directions for DYMBARC is challenging due to the large solution space, machine component constraints, and optimization parameters, posing a highly non‐convex optimization problem.Purpose: To establish DYMBARC and solve the pathfinding challenge by employing direct aperture optimization (DAO) to determine the table angles and gantry angle ranges of photon and electron arcs for different clinically motivated cases.Methods: The method starts by generating a grid of beam directions based on user‐defined resolutions along the gantry and table angle axes for each beam quality considered. Beam directions causing collisions or entering through the end of CT are excluded. For electrons, a fixed source‐to‐surface distance of 80 cm is used to reduce in‐air scatter. Electron beam energies with insufficient range to reach the target or beam directions impinging on the table before reaching the patient are excluded. The remaining beam directions form the pathfinding solution space. Promising photon and electron MLC‐defined apertures, with associated monitor unit (MU) weights, are iteratively added using a hybrid‐DAO algorithm. This algorithm combines column generation to add apertures and simulated annealing to further refine aperture shapes and weights. Apertures are added until the requested number of paths are formed and the user‐defined maximum total gantry angle range is reached. Paths are resampled to a finer gantry angle resolution and subject to DAO for simultaneous optimization of beam intensities along the photon/electron arcs. Subsequent final dose calculation and MU weight reoptimization result in a deliverable DYMBARC plan. DYMBARC plans are created for three clinically motivated cases (brain, breast, and pelvis) and compared to DYMBARC variants: colli‐DTRT (dynamic collimator trajectory radiotherapy) using non‐coplanar photon arcs; and Arc‐MBRT (mixed beam radiotherapy) using photons and electrons but restricted to coplanar setup. Additionally, a manually defined volumetric modulated arc therapy (VMAT) setup serves as a reference clinical technique. Dose distributions, dose‐volume histograms, and dosimetric endpoints are evaluated. Dosimetric validation with radiochromic film measurements (gamma evaluation, 3% / 2 mm (global), 10% dose threshold) is performed on a TrueBeam system in developer mode for one case.Results: While maintaining similar target coverage and homogeneity, DYMBARC reduced mean doses to organs‐at‐risk compared to VMAT by an average of 3.2, 0.5, and 2.9 Gy for the brain, breast, and pelvis cases, respectively. Similar or smaller mean dose reductions were observed for Arc‐MBRT or colli‐DTRT, compared to VMAT. Electron contributions to the mean planning target volume dose ranged from 2% to 34% for DYMBARC and from 11% to 40% for Arc‐MBRT. Measurement validation showed >99.7% gamma passing rate.Conclusions: DYMBARC was successfully established using a dosimetrically optimized pathfinding approach, combining non‐coplanarity with mixed beam modality. DYMBARC facilitated the determination of photon and electron contributions on a case‐by‐case basis, enhancing more personalized treatment modalities.
- 26 October 2024
- Published by Wiley in Medical Physics
- Vol. 52 (1) , 489-503
Open AccessDosimetric optimization for dynamic mixed beam arc therapy (DYMBARC)
Background: Non‐coplanarity and mixed beam modality could be combined to further enhance dosimetric treatment plan quality. We introduce dynamic mixed beam arc therapy (DYMBARC) as an innovative technique that combines non‐coplanar photon and electron arcs, dynamic gantry and collimator rotations, and intensity modulation with photon multileaf collimator (MLC). However, finding favorable beam directions for DYMBARC is challenging due to the large solution space, machine component constraints, and optimization parameters, posing a highly non‐convex optimization problem.Purpose: To establish DYMBARC and solve the pathfinding challenge by employing direct aperture optimization (DAO) to determine the table angles and gantry angle ranges of photon and electron arcs for different clinically motivated cases.Methods: The method starts by generating a grid of beam directions based on user‐defined resolutions along the gantry and table angle axes for each beam quality considered. Beam directions causing collisions or entering through the end of CT are excluded. For electrons, a fixed source‐to‐surface distance of 80 cm is used to reduce in‐air scatter. Electron beam energies with insufficient range to reach the target or beam directions impinging on the table before reaching the patient are excluded. The remaining beam directions form the pathfinding solution space. Promising photon and electron MLC‐defined apertures, with associated monitor unit (MU) weights, are iteratively added using a hybrid‐DAO algorithm. This algorithm combines column generation to add apertures and simulated annealing to further refine aperture shapes and weights. Apertures are added until the requested number of paths are formed and the user‐defined maximum total gantry angle range is reached. Paths are resampled to a finer gantry angle resolution and subject to DAO for simultaneous optimization of beam intensities along the photon/electron arcs. Subsequent final dose calculation and MU weight reoptimization result in a deliverable DYMBARC plan. DYMBARC plans are created for three clinically motivated cases (brain, breast, and pelvis) and compared to DYMBARC variants: colli‐DTRT (dynamic collimator trajectory radiotherapy) using non‐coplanar photon arcs; and Arc‐MBRT (mixed beam radiotherapy) using photons and electrons but restricted to coplanar setup. Additionally, a manually defined volumetric modulated arc therapy (VMAT) setup serves as a reference clinical technique. Dose distributions, dose‐volume histograms, and dosimetric endpoints are evaluated. Dosimetric validation with radiochromic film measurements (gamma evaluation, 3% / 2 mm (global), 10% dose threshold) is performed on a TrueBeam system in developer mode for one case.Results: While maintaining similar target coverage and homogeneity, DYMBARC reduced mean doses to organs‐at‐risk compared to VMAT by an average of 3.2, 0.5, and 2.9 Gy for the brain, breast, and pelvis cases, respectively. Similar or smaller mean dose reductions were observed for Arc‐MBRT or colli‐DTRT, compared to VMAT. Electron contributions to the mean planning target volume dose ranged from 2% to 34% for DYMBARC and from 11% to 40% for Arc‐MBRT. Measurement validation showed >99.7% gamma passing rate.Conclusions: DYMBARC was successfully established using a dosimetrically optimized pathfinding approach, combining non‐coplanarity with mixed beam modality. DYMBARC facilitated the determination of photon and electron contributions on a case‐by‐case basis, enhancing more personalized treatment modalities.
- Open Access
- 12 September 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 185009
A dosimetrically motivated pathfinding approach for non-isocentric dynamic trajectory radiotherapy
Objective. Non-isocentric dynamic trajectory radiotherapy (DTRT) involves dynamic table translations in synchrony with intensity modulation and dynamic gantry, table, and/or collimator rotation. This work aims to develop and evaluate a novel dosimetrically motivated path determination technique for non-isocentric DTRT. Approach. The path determination considers all available beam directions, given on a user-specified grid of gantry angle, table angle, and longitudinal, vertical, and lateral table position. Additionally, the source-to-target distance of all beam directions can be extended by moving the table away from the gantry along the central beam axis to increase the collision-free space. The path determination uses a column generation algorithm to iteratively add beam directions to paths until a user-defined total path length is reached. A subsequent direct aperture optimization of the intensity modulation along the paths creates deliverable plans. Non-isocentric DTRT plans using the path determination and using a manual path setup were created for a craniospinal and a spinal irradiation case. Furthermore, VMAT, isocentric DTRT, and non-isocentric DTRT plans are created for a breast, head and neck (H&N), and esophagus case. Additionally, a HyperArc plan is created for the H&N case. The plans are compared in terms of the dosimetric treatment plan quality and estimated delivery time. Main results. For the craniospinal and spinal irradiation case, using path determination results in dose distributions with improved conformity but a slightly worse target homogeneity compared to manual path setup. The non-isocentric DTRT plans maintained target coverage while reducing the mean dose to organs-at-risk on average by 1.7 Gy (breast), 1.0 Gy (H&N), and 1.6 Gy (esophagus) compared to the VMAT plans and by 0.8 Gy (breast), 0.6 Gy (H&N), and 0.8 Gy (esophagus) compared to the isocentric DTRT plans. Significance. A general dosimetrically motivated path determination applicable to non-isocentric DTRT plans is successfully developed, further advancing the treatment planning for non-isocentric DTRT.
- 12 September 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (18) , 185009
Open AccessA dosimetrically motivated pathfinding approach for non-isocentric dynamic trajectory radiotherapy
Objective. Non-isocentric dynamic trajectory radiotherapy (DTRT) involves dynamic table translations in synchrony with intensity modulation and dynamic gantry, table, and/or collimator rotation. This work aims to develop and evaluate a novel dosimetrically motivated path determination technique for non-isocentric DTRT. Approach. The path determination considers all available beam directions, given on a user-specified grid of gantry angle, table angle, and longitudinal, vertical, and lateral table position. Additionally, the source-to-target distance of all beam directions can be extended by moving the table away from the gantry along the central beam axis to increase the collision-free space. The path determination uses a column generation algorithm to iteratively add beam directions to paths until a user-defined total path length is reached. A subsequent direct aperture optimization of the intensity modulation along the paths creates deliverable plans. Non-isocentric DTRT plans using the path determination and using a manual path setup were created for a craniospinal and a spinal irradiation case. Furthermore, VMAT, isocentric DTRT, and non-isocentric DTRT plans are created for a breast, head and neck (H&N), and esophagus case. Additionally, a HyperArc plan is created for the H&N case. The plans are compared in terms of the dosimetric treatment plan quality and estimated delivery time. Main results. For the craniospinal and spinal irradiation case, using path determination results in dose distributions with improved conformity but a slightly worse target homogeneity compared to manual path setup. The non-isocentric DTRT plans maintained target coverage while reducing the mean dose to organs-at-risk on average by 1.7 Gy (breast), 1.0 Gy (H&N), and 1.6 Gy (esophagus) compared to the VMAT plans and by 0.8 Gy (breast), 0.6 Gy (H&N), and 0.8 Gy (esophagus) compared to the isocentric DTRT plans. Significance. A general dosimetrically motivated path determination applicable to non-isocentric DTRT plans is successfully developed, further advancing the treatment planning for non-isocentric DTRT.
- Open Access
- 12 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165032
Robust optimization and assessment of dynamic trajectory and mixed-beam arc radiotherapy: a preliminary study
Objective. Dynamic trajectory radiotherapy (DTRT) and dynamic mixed-beam arc therapy (DYMBARC) exploit non-coplanarity and, for DYMBARC, simultaneously optimized photon and electron beams. Margin concepts to account for set-up uncertainties during delivery are ill-defined for electron fields. We develop robust optimization for DTRT&DYMBARC and compare dosimetric plan quality and robustness for both techniques and both optimization strategies for four cases. Approach. Cases for different treatment sites and clinical target volume (CTV) to planning target volume (PTV) margins, m , were investigated. Dynamic gantry-table-collimator photon paths were optimized to minimize PTV/organ-at-risk (OAR) overlap in beam’s-eye-view and minimize potential photon multileaf collimator (MLC) travel. For DYMBARC plans, non-isocentric partial electron arcs or static fields with shortened source-to-surface distance (80 cm) were added. Direct aperture optimization (DAO) was used to simultaneously optimize MLC-based intensity modulation for both photon and electron beams yielding deliverable PTV-based DTRT&DYMBARC plans. Robust-optimized plans used the same paths/arcs/fields. DAO with stochastic programming was used for set-up uncertainties with equal weights in all translational directions and magnitude δ such that m = 0.7 δ . Robust analysis considered random errors in all directions with or without an additional systematic error in the worst 3D direction for the adjacent OARs. Main results. Electron contribution was 7%–41% of target dose depending on the case and optimization strategy for DYMBARC. All techniques achieved similar CTV coverage in the nominal (no error) scenario. OAR sparing was overall better in the DYMBARC plans than in the DTRT plans and DYMBARC plans were generally more robust to the considered uncertainties. OAR sparing was better in the PTV-based than in robust-optimized plans for OARs abutting or overlapping with the target volume, but more affected by uncertainties. Significance. Better plan robustness can be achieved with robust optimization than with margins. Combining electron arcs/fields with non-coplanar photon trajectories further improves robustness and OAR sparing.
- 12 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165032
Open AccessRobust optimization and assessment of dynamic trajectory and mixed-beam arc radiotherapy: a preliminary study
Objective. Dynamic trajectory radiotherapy (DTRT) and dynamic mixed-beam arc therapy (DYMBARC) exploit non-coplanarity and, for DYMBARC, simultaneously optimized photon and electron beams. Margin concepts to account for set-up uncertainties during delivery are ill-defined for electron fields. We develop robust optimization for DTRT&DYMBARC and compare dosimetric plan quality and robustness for both techniques and both optimization strategies for four cases. Approach. Cases for different treatment sites and clinical target volume (CTV) to planning target volume (PTV) margins, m , were investigated. Dynamic gantry-table-collimator photon paths were optimized to minimize PTV/organ-at-risk (OAR) overlap in beam’s-eye-view and minimize potential photon multileaf collimator (MLC) travel. For DYMBARC plans, non-isocentric partial electron arcs or static fields with shortened source-to-surface distance (80 cm) were added. Direct aperture optimization (DAO) was used to simultaneously optimize MLC-based intensity modulation for both photon and electron beams yielding deliverable PTV-based DTRT&DYMBARC plans. Robust-optimized plans used the same paths/arcs/fields. DAO with stochastic programming was used for set-up uncertainties with equal weights in all translational directions and magnitude δ such that m = 0.7 δ . Robust analysis considered random errors in all directions with or without an additional systematic error in the worst 3D direction for the adjacent OARs. Main results. Electron contribution was 7%–41% of target dose depending on the case and optimization strategy for DYMBARC. All techniques achieved similar CTV coverage in the nominal (no error) scenario. OAR sparing was overall better in the DYMBARC plans than in the DTRT plans and DYMBARC plans were generally more robust to the considered uncertainties. OAR sparing was better in the PTV-based than in robust-optimized plans for OARs abutting or overlapping with the target volume, but more affected by uncertainties. Significance. Better plan robustness can be achieved with robust optimization than with margins. Combining electron arcs/fields with non-coplanar photon trajectories further improves robustness and OAR sparing.
- Open Access
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e644
Comparison of Dynamic Trajectory Radiotherapy and Volumetric Modulated Arc Therapy for Loco-Regionally Advanced Oropharyngeal Cancer
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e644
Open AccessComparison of Dynamic Trajectory Radiotherapy and Volumetric Modulated Arc Therapy for Loco-Regionally Advanced Oropharyngeal Cancer
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S826-S827
PD-0978 Electron modulated arc therapy for breast boost: development of a treatment planning process
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S826-S827
PD-0978 Electron modulated arc therapy for breast boost: development of a treatment planning process
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S509-S511
OC-0621 Dosimetric beam-angle optimization for non-coplanar dynamic-collimator trajectory radiotherapy
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S509-S511
OC-0621 Dosimetric beam-angle optimization for non-coplanar dynamic-collimator trajectory radiotherapy
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1638-S1639
PO-1893 Gated dynamic trajectory radiotherapy: feasibility, mechanical accuracy and dosimetric validation
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1638-S1639
PO-1893 Gated dynamic trajectory radiotherapy: feasibility, mechanical accuracy and dosimetric validation