Hiroki Ikeuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroki Ikeuchi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Goro Matsumiya
Chiba University Graduate School of Medicine
2 shared publications - Hironobu Nishiori
Department of Cardiovascular Surgery, Chiba University Hospital, Chiba, Japan
2 shared publications Goro Matsumiya
Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Chiba, Japan
1 shared publication- Hideki Ueda
Minami-Senju Hospital , Division of Cardiology, Tokyo, Japan
1 shared publication Hiroki Kohno
Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Chiba, Japan
1 shared publicationKaoru Matsuura
Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Chiba, Japan
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Editorial Committee of Annals of Thoracic and Cardiovascular Surgery in Annals of Thoracic and Cardiovascular Surgery
- Vol. 32 (1)
Preoperative Risk Stratification of Cerebral Infarction in Aortic Arch Surgery Using Quantitative Atheroma Assessment with Computational Fluid Dynamics
Purpose: We developed a quantitative method to evaluate aortic atheroma and investigated its association with postoperative cerebral infarction (CI) after aortic arch surgery. In addition, computational fluid dynamics (CFD) analysis was performed to explore the underlying hemodynamic mechanisms.Methods: We retrospectively analyzed 72 patients who underwent aortic arch surgery. Atheroma scores were calculated from preoperative computed tomography, and a qualitative assessment was also performed. Multivariate logistic regression identified risk factors for CI. CFD analysis was conducted in selected patients to provide mechanistic insights.Results: CI occurred in 8 patients (11.1%). Atheroma scores were significantly higher in patients with CI (P = .02), whereas qualitative assessment did not predict CI. Receiver operating characteristic analysis showed an area under the curve of 0.79 for the ascending aorta, with a cutoff of 352.3. Multivariate analysis including age demonstrated that hemoglobin A1c and an ascending atheroma score ≥352.3 were independent predictors of CI. CFD demonstrated high wall shear stress in the ascending aorta, providing mechanistic insight into embolic events.Conclusions: Quantitative assessment of ascending aortic atheroma provides superior risk stratification compared with qualitative evaluation. CFD findings offer mechanistic insight into embolic risk, supporting the clinical relevance of atheroma burden in aortic arch surgery.
- 1 January 2026
- Published by Editorial Committee of Annals of Thoracic and Cardiovascular Surgery in Annals of Thoracic and Cardiovascular Surgery
- Vol. 32 (1)
Open AccessPreoperative Risk Stratification of Cerebral Infarction in Aortic Arch Surgery Using Quantitative Atheroma Assessment with Computational Fluid Dynamics
Purpose: We developed a quantitative method to evaluate aortic atheroma and investigated its association with postoperative cerebral infarction (CI) after aortic arch surgery. In addition, computational fluid dynamics (CFD) analysis was performed to explore the underlying hemodynamic mechanisms.Methods: We retrospectively analyzed 72 patients who underwent aortic arch surgery. Atheroma scores were calculated from preoperative computed tomography, and a qualitative assessment was also performed. Multivariate logistic regression identified risk factors for CI. CFD analysis was conducted in selected patients to provide mechanistic insights.Results: CI occurred in 8 patients (11.1%). Atheroma scores were significantly higher in patients with CI (P = .02), whereas qualitative assessment did not predict CI. Receiver operating characteristic analysis showed an area under the curve of 0.79 for the ascending aorta, with a cutoff of 352.3. Multivariate analysis including age demonstrated that hemoglobin A1c and an ascending atheroma score ≥352.3 were independent predictors of CI. CFD demonstrated high wall shear stress in the ascending aorta, providing mechanistic insight into embolic events.Conclusions: Quantitative assessment of ascending aortic atheroma provides superior risk stratification compared with qualitative evaluation. CFD findings offer mechanistic insight into embolic risk, supporting the clinical relevance of atheroma burden in aortic arch surgery.
- Open Access
- 3 September 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (9) , rjae601
Surgical explantation of the WATCHMAN device and right atrial thrombus: a case report
A 74-year-old male with a history of cardioembolic stroke, chronic atrial fibrillation, and cerebral hemorrhage, who had undergone left atrial appendage closure using the WATCHMAN device 1 year prior, was diagnosed with a 25-mm intra-cardiac mass in the right atrium. The patient underwent the surgical removal of the right atrial mass and the explantation of the WATCHMAN device. The WATCHMAN device was explanted with an external incision at the base of the left atrial appendage, facilitating the removal of the device and the closure of the appendage through direct suturing. The pathological examination confirmed the right atrial mass to be a thrombus. The patient was discharged on postoperative Day 13. From the perspectives of simplicity and radicality, the external approach could be a good option.
- 3 September 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (9) , rjae601
Open AccessSurgical explantation of the WATCHMAN device and right atrial thrombus: a case report
A 74-year-old male with a history of cardioembolic stroke, chronic atrial fibrillation, and cerebral hemorrhage, who had undergone left atrial appendage closure using the WATCHMAN device 1 year prior, was diagnosed with a 25-mm intra-cardiac mass in the right atrium. The patient underwent the surgical removal of the right atrial mass and the explantation of the WATCHMAN device. The WATCHMAN device was explanted with an external incision at the base of the left atrial appendage, facilitating the removal of the device and the closure of the appendage through direct suturing. The pathological examination confirmed the right atrial mass to be a thrombus. The patient was discharged on postoperative Day 13. From the perspectives of simplicity and radicality, the external approach could be a good option.
- Open Access
- 1 August 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (8) , rjae478
False lumen embolization and false lumen stent-graft techniques for ruptured post-dissection thoracoabdominal aneurysm
This report details the successful endovascular repair of a ruptured thoracoabdominal aortic aneurysm in a patient with chronic type B aortic dissection. The procedure consisted of thoracic endovascular aortic repair, abdominal endovascular aortic repair, false lumen (FL) embolization with Candy-Plug, and FL stent-graft technique. The approach effectively regulated FL inflow, achieving complete FL closure. The patient was discharged without major complications including spinal cord ischemia or renal failure, and the long-term outcome is also favorable with reduction of the aneurysm size. The follow-up results have shown a reduction in the aneurysm size. This less invasive method could be an option of treatments for post-dissection thoracoabdominal aortic aneurysms, especially in ruptured cases.
- 1 August 2024
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2024 (8) , rjae478
Open AccessFalse lumen embolization and false lumen stent-graft techniques for ruptured post-dissection thoracoabdominal aneurysm
This report details the successful endovascular repair of a ruptured thoracoabdominal aortic aneurysm in a patient with chronic type B aortic dissection. The procedure consisted of thoracic endovascular aortic repair, abdominal endovascular aortic repair, false lumen (FL) embolization with Candy-Plug, and FL stent-graft technique. The approach effectively regulated FL inflow, achieving complete FL closure. The patient was discharged without major complications including spinal cord ischemia or renal failure, and the long-term outcome is also favorable with reduction of the aneurysm size. The follow-up results have shown a reduction in the aneurysm size. This less invasive method could be an option of treatments for post-dissection thoracoabdominal aortic aneurysms, especially in ruptured cases.