Alikhan B. Fidai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alikhan B. Fidai has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Robayo
Department of Neurological Surgery Weill Cornell Medicine Och Spine at New York Presbyterian Hospital New York NY USA
3 shared publications - Chibuikem Anthony Ikwuegbuenyi
Weill Cornell Medicine
3 shared publications - Lawrence J. Bonassar
Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
3 shared publications - Ashley Cardenas
Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
2 shared publications Ibrahim Hussain
Department of Neurological Surgery, Och Spine at NewYork-Presbyterian Hospital, Weill Cornell Medicine, New York, New York, USA
2 shared publications- Ibrahim Hussain
Department of Neurological Surgery, Och Spine at New York Presbyterian Hospital, Weill Cornell Medicine, New York, New York, USA
2 shared publications
Latest Publications
- Open Access
- 21 April 2026
- Published by Elsevier in World Neurosurgery
- Vol. 211, 124998
Safety and Feasibility of Intradiscal Autologous Bone Marrow Aspirate Concentrate at the Time of Lumbar Microdiscectomy: A Prospective Pilot Study
- 21 April 2026
- Published by Elsevier in World Neurosurgery
- Vol. 211, 124998
Open AccessSafety and Feasibility of Intradiscal Autologous Bone Marrow Aspirate Concentrate at the Time of Lumbar Microdiscectomy: A Prospective Pilot Study
- Open Access
- 2 June 2025
- Published by Elsevier in World Neurosurgery
- Vol. 199, 124132
Bioactive Therapies for Degenerative Disc Disease: Challenges and Innovations
- 2 June 2025
- Published by Elsevier in World Neurosurgery
- Vol. 199, 124132
Open AccessBioactive Therapies for Degenerative Disc Disease: Challenges and Innovations
- Open Access
- 21 May 2025
- Published by Elsevier in World Neurosurgery
- Vol. 200, 124107
Bioactive Therapies for Degenerative Disc Disease: Current State of the Art and Clinical Applications
- 21 May 2025
- Published by Elsevier in World Neurosurgery
- Vol. 200, 124107
Open AccessBioactive Therapies for Degenerative Disc Disease: Current State of the Art and Clinical Applications
- Open Access
Flexible support material maintains disc height and supports the formation of hydrated tissue engineered intervertebral discs in vivo
Background: Mechanical augmentation upon implantation is essential for the long‐term success of tissue‐engineered intervertebral discs (TE‐IVDs). Previous studies utilized stiffer materials to fabricate TE‐IVD support structures. However, these materials undergo various failure modes in the mechanically challenging IVD microenvironment. FlexiFil (FPLA) is an elastomeric 3D printing filament that is amenable to the fabrication of support structures. However, no present study has evaluated the efficacy of a flexible support material to preserve disc height and support the formation of hydrated tissues in a large animal model.Methods: We leveraged results from our previously developed FE model of the minipig spine to design and test TE‐IVD support cages comprised of FPLA and PLA. Specifically, we performed indentation to assess implant mechanical response and scanning electron microscopy to visualize microscale damage. We then implanted FPLA and PLA support cages for 6 weeks in the minipig cervical spine and monitored disc height via weekly x‐rays. TE‐IVDs cultured in FPLA were also implanted for 6 weeks with weekly x‐rays and terminal T2 MRIs to quantify tissue hydration at study endpoint.Results: Results demonstrated that FPLA cages withstood nearly twice the deformation of PLA without detrimental changes in mechanical performance and minimal damage. In vivo, FPLA cages and stably implanted TE‐IVDs restored native disc height and supported the formation of hydrated tissues in the minipig spine. Displaced TE‐IVDs yielded disc heights that were superior to PLA or discectomy‐treated levels.Conclusions: FPLA holds great promise as a flexible and bioresorbable material for enhancing the long‐term success of TE‐IVD implants.
Open AccessFlexible support material maintains disc height and supports the formation of hydrated tissue engineered intervertebral discs in vivo
Background: Mechanical augmentation upon implantation is essential for the long‐term success of tissue‐engineered intervertebral discs (TE‐IVDs). Previous studies utilized stiffer materials to fabricate TE‐IVD support structures. However, these materials undergo various failure modes in the mechanically challenging IVD microenvironment. FlexiFil (FPLA) is an elastomeric 3D printing filament that is amenable to the fabrication of support structures. However, no present study has evaluated the efficacy of a flexible support material to preserve disc height and support the formation of hydrated tissues in a large animal model.Methods: We leveraged results from our previously developed FE model of the minipig spine to design and test TE‐IVD support cages comprised of FPLA and PLA. Specifically, we performed indentation to assess implant mechanical response and scanning electron microscopy to visualize microscale damage. We then implanted FPLA and PLA support cages for 6 weeks in the minipig cervical spine and monitored disc height via weekly x‐rays. TE‐IVDs cultured in FPLA were also implanted for 6 weeks with weekly x‐rays and terminal T2 MRIs to quantify tissue hydration at study endpoint.Results: Results demonstrated that FPLA cages withstood nearly twice the deformation of PLA without detrimental changes in mechanical performance and minimal damage. In vivo, FPLA cages and stably implanted TE‐IVDs restored native disc height and supported the formation of hydrated tissues in the minipig spine. Displaced TE‐IVDs yielded disc heights that were superior to PLA or discectomy‐treated levels.Conclusions: FPLA holds great promise as a flexible and bioresorbable material for enhancing the long‐term success of TE‐IVD implants.