Atousa Parsaei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Atousa Parsaei has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Amin Komeili
Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, AB T2N1N4, Canada
4 shared publications - Reza Ahmadi
Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, AB T2N1N4, Canada
4 shared publications - Hamidreza Heidary
Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
3 shared publications - Samira Fazeli Veisari
Department of Biomedical Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada
3 shared publications - Shahram Rasoulian
Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB T2N1N4, Canada
3 shared publications - Walter Herzog
Human performance laboratory, Faculty of Kinesiology University of Calgary Calgary Alberta Canada
2 shared publications
Latest Publications
- Open Access
Reproducibility of Cycling Kinetics on an Ergometer Designed to Quantify Asymmetry
Cycling-based rehabilitation is a non-invasive intervention for individuals with lower limb asymmetries. However, current cycling devices lack comprehensive biomechanical feedback and cannot assess asymmetry. Our lab has developed a novel cycle ergometer equipped with three-dimensional force pedals, a seat post and handlebar force sensors, which allow for a comprehensive analysis of asymmetry across a fatiguing task. This study assessed the reproducibility of the cycling kinetics and asymmetry index derived from this device during incremental and constant load cycling tasks to volitional failure. Eighteen participants completed incremental and constant-load tests, each across two identical sessions. Pedal forces and power were analyzed for each leg individually, and handlebar forces and seat post mediolateral sway were recorded during cycling. Normalized symmetry index (NSI), a metric quantifying the degree of asymmetry between limbs, was calculated for each variable. The reproducibility of the device was assessed using repeated measures analysis of variance and intraclass correlation coefficients (ICC). No significant session or interaction effects were found for pedal, handlebar, and seat post measures (all p > 0.05). Time effects were observed for pedal force and power in the incremental test (all p < 0.001). NSI values were reproducible with high ICC values (≥0.70) for force and power. The results suggest that this ergometer offers reproducible cycling kinetics and asymmetry measures across a fatiguing task. The findings support the application of this ergometer in research and rehabilitation settings.
Open AccessReproducibility of Cycling Kinetics on an Ergometer Designed to Quantify Asymmetry
Cycling-based rehabilitation is a non-invasive intervention for individuals with lower limb asymmetries. However, current cycling devices lack comprehensive biomechanical feedback and cannot assess asymmetry. Our lab has developed a novel cycle ergometer equipped with three-dimensional force pedals, a seat post and handlebar force sensors, which allow for a comprehensive analysis of asymmetry across a fatiguing task. This study assessed the reproducibility of the cycling kinetics and asymmetry index derived from this device during incremental and constant load cycling tasks to volitional failure. Eighteen participants completed incremental and constant-load tests, each across two identical sessions. Pedal forces and power were analyzed for each leg individually, and handlebar forces and seat post mediolateral sway were recorded during cycling. Normalized symmetry index (NSI), a metric quantifying the degree of asymmetry between limbs, was calculated for each variable. The reproducibility of the device was assessed using repeated measures analysis of variance and intraclass correlation coefficients (ICC). No significant session or interaction effects were found for pedal, handlebar, and seat post measures (all p > 0.05). Time effects were observed for pedal force and power in the incremental test (all p < 0.001). NSI values were reproducible with high ICC values (≥0.70) for force and power. The results suggest that this ergometer offers reproducible cycling kinetics and asymmetry measures across a fatiguing task. The findings support the application of this ergometer in research and rehabilitation settings.
- Open Access
- 30 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 192 (Pt A) , 110295
Comparison of kinematics and kinetics between OpenCap and a marker-based motion capture system in cycling
- 30 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 192 (Pt A) , 110295
Open AccessComparison of kinematics and kinetics between OpenCap and a marker-based motion capture system in cycling
- Open Access
A Machine Learning Approach for Predicting Pedaling Force Profile in Cycling
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower-limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive postprocessing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2 min pedaling task at two different self-selected (58 ± 5 RPM) and higher (72 ± 7 RPM) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants’ weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15 ± 0.02 and 0.26 ± 0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20 ± 0.04 and 0.22 ± 0.04 at self-selected cadence. The NN model’s low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.
Open AccessA Machine Learning Approach for Predicting Pedaling Force Profile in Cycling
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower-limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive postprocessing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2 min pedaling task at two different self-selected (58 ± 5 RPM) and higher (72 ± 7 RPM) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants’ weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15 ± 0.02 and 0.26 ± 0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20 ± 0.04 and 0.22 ± 0.04 at self-selected cadence. The NN model’s low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.
- Open Access
- 7 August 2024
- Published by MDPI AG in Preprints.org
A Machine Learning Approach for Predicting Pedaling Force Profile in Cycling
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive post-processing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2-minute pedaling task at two different self-selected (58±5 rpm) and higher (72±7 rpm) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants' weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15±0.02 and 0.26±0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20±0.04 and 0.22±0.04 at self-selected cadence. The NN model's low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.
- 7 August 2024
- Published by MDPI AG in Preprints.org
Open AccessA Machine Learning Approach for Predicting Pedaling Force Profile in Cycling
Accurate measurement of pedaling kinetics and kinematics is vital for optimizing rehabilitation, exercise training, and understanding musculoskeletal biomechanics. Pedal reaction force, the main external force in cycling, is essential for musculoskeletal modeling and closely correlates with lower limb muscle activity and joint reaction forces. However, sensor instrumentation like 3-axis pedal force sensors is costly and requires extensive post-processing. Recent advancements in machine learning (ML), particularly neural network (NN) models, provide promising solutions for kinetic analyses. In this study, an NN model was developed to predict radial and mediolateral forces, providing a low-cost solution to study pedaling biomechanics with stationary cycling ergometers. Fifteen healthy individuals performed a 2-minute pedaling task at two different self-selected (58±5 rpm) and higher (72±7 rpm) cadences. Pedal forces were recorded using a 3-axis force system. The dataset included pedal force, crank angle, cadence, power, and participants' weight and height. The NN model achieved an inter-subject normalized root mean square error (nRMSE) of 0.15±0.02 and 0.26±0.05 for radial and mediolateral forces at high cadence, respectively, and 0.20±0.04 and 0.22±0.04 at self-selected cadence. The NN model's low computational time suits real-time pedal force predictions, matching the accuracy of previous ML algorithms for estimating ground reaction forces in gait.