Jingbo Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jingbo Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Guiling Wu
Shanghai Jiao Tong University
4 shared publications - Jianping Chen
State Key Laboratory of Photonics and Communications, Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications Wei Zhao
State Key Laboratory of Photonics and Communications, Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications- Baohua Qi
Institute of High Energy Physics, Chinese Academy of Sciences. Yuquan Road 19B, 100049 Beijing, China
1 shared publication - Bo-Xiang Yu
Institute of High Energy Physics
1 shared publication D. Liu
Tsung-Dao Lee Institute, Shanghai JiaoTong University, Shanghai, 200240, P.R.`China
1 shared publication
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (13) , 5388-5395
Joint Phase–Amplitude Controlled Microwave Photonic I/Q Mixer for Image-Rejected Multichannel Reception
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (13) , 5388-5395
Joint Phase–Amplitude Controlled Microwave Photonic I/Q Mixer for Image-Rejected Multichannel Reception
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (17) , 1-9
Dual Stimulated Brillouin Scattering Based Wideband Instantaneous Frequency Measurement
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (17) , 1-9
Dual Stimulated Brillouin Scattering Based Wideband Instantaneous Frequency Measurement
- 8 August 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (16) , 5022-5025
Ultra-broadband and high-accuracy instantaneous frequency measurement based on frequency shift loop and stimulated Brillouin scattering
We propose an ultra-broadband and high-accuracy instantaneous frequency measurement (IFM) scheme based on frequency shift loop (FSL) and stimulated Brillouin scattering (SBS). The linear frequency modulation (LFM) signal with larger bandwidth is obtained by the FSL and is optically filtered by the SBS effect to construct a frequency-to-time mapping between the time difference of pulses and the frequency of the signal under test. The proposed IFM scheme is experimentally demonstrated. A 10-GHz LFM signal is extended to 80 GHz with a spectral flatness of approximately 1.32 dB by the FSL. The frequency measurement errors less than 12 MHz in 0–40 GHz and 5 MHz in 5–30 GHz are reached by exciting SBS through using the -1st modulation sideband and the -2nd modulation sideband, respectively. The frequency measurement resolution of multi-tone is about 100 MHz.
- 8 August 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (16) , 5022-5025
Ultra-broadband and high-accuracy instantaneous frequency measurement based on frequency shift loop and stimulated Brillouin scattering
We propose an ultra-broadband and high-accuracy instantaneous frequency measurement (IFM) scheme based on frequency shift loop (FSL) and stimulated Brillouin scattering (SBS). The linear frequency modulation (LFM) signal with larger bandwidth is obtained by the FSL and is optically filtered by the SBS effect to construct a frequency-to-time mapping between the time difference of pulses and the frequency of the signal under test. The proposed IFM scheme is experimentally demonstrated. A 10-GHz LFM signal is extended to 80 GHz with a spectral flatness of approximately 1.32 dB by the FSL. The frequency measurement errors less than 12 MHz in 0–40 GHz and 5 MHz in 5–30 GHz are reached by exciting SBS through using the -1st modulation sideband and the -2nd modulation sideband, respectively. The frequency measurement resolution of multi-tone is about 100 MHz.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (24) , 8590-8597
Dual-Comb Broadband Microwave Vector Network Analyzer
We propose a dual-comb broadband microwave vector network analyzer (VNA). One of the optical frequency combs (OFCs) beats with a continuous wave (CW) light to generate the stimulus signal of the device under test, which is a multi-tone signal within a wide bandwidth. Another OFC with slightly different repetition frequency samples the scattering signal and then coherently beats with the CW light, to convert the scattering signal into the intermediate frequency (IF) signal. Thanks to the dual-comb technology, the requirement for the electrical devices is lessened. A wide measurement frequency range can be achieved by sweeping the frequency of the CW light within a narrow range, giving the credit that the multi frequencies in the stimulus signal sweep simultaneously. An electrical back end with narrow bandwidth and low sampling rate can be used to acquire the scattering parameters (S parameters), owing to the fact that the IF signal locates at the low-frequency band and has the fixed frequencies during frequency sweeping. In the experiments, the S parameters of a 25-GHz low-pass filter within 0.001-69.88 GHz is measured by the proposed VNA, utilizing a microwave signal with a frequency sweeping range of about 5 GHz and an electrical back end with a bandwidth of 200 MHz and a sampling rate of 312.5 MHz.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (24) , 8590-8597
Dual-Comb Broadband Microwave Vector Network Analyzer
We propose a dual-comb broadband microwave vector network analyzer (VNA). One of the optical frequency combs (OFCs) beats with a continuous wave (CW) light to generate the stimulus signal of the device under test, which is a multi-tone signal within a wide bandwidth. Another OFC with slightly different repetition frequency samples the scattering signal and then coherently beats with the CW light, to convert the scattering signal into the intermediate frequency (IF) signal. Thanks to the dual-comb technology, the requirement for the electrical devices is lessened. A wide measurement frequency range can be achieved by sweeping the frequency of the CW light within a narrow range, giving the credit that the multi frequencies in the stimulus signal sweep simultaneously. An electrical back end with narrow bandwidth and low sampling rate can be used to acquire the scattering parameters (S parameters), owing to the fact that the IF signal locates at the low-frequency band and has the fixed frequencies during frequency sweeping. In the experiments, the S parameters of a 25-GHz low-pass filter within 0.001-69.88 GHz is measured by the proposed VNA, utilizing a microwave signal with a frequency sweeping range of about 5 GHz and an electrical back end with a bandwidth of 200 MHz and a sampling rate of 312.5 MHz.
- Open Access
- 1 May 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (05) , P05006
Scintillator tile batch test of CEPC AHCAL
Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm (PFA). The AHCAL of CEPC uses steel as the absorber and scintillator tiles read out by Silicon Photo-Multipliers (SiPMs) as the sensitive medium. The energy linearity and resolution of the calorimeter depend on the light yield uniformity of the sensitive medium. It is essential to qualify the entire detector production in order to select scintillator tiles with the uniformity of light yield within 10%. An automated batch test platform has been designed with 144 channels and an automated 3D servo motor. The paper summarizes the tests performed on more than 15000 scintillator tiles, and the SiPMs work at 59 V (overvoltage: 5 V). The measured light yield, corrected for the set-up response non-uniformity, is around 12.9 p.e. About 91.6% of scintillators (14219 pieces) are qualified within 10% of the light yield window.
- 1 May 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (05) , P05006
Open AccessScintillator tile batch test of CEPC AHCAL
Hadron calorimeter (HCAL) is an essential sub-detector of the baseline detector system for Circular Electron Positron Collider (CEPC). We plan to build an Analog Hadron CALorimeter (AHCAL) prototype based on the Particle Flow Algorithm (PFA). The AHCAL of CEPC uses steel as the absorber and scintillator tiles read out by Silicon Photo-Multipliers (SiPMs) as the sensitive medium. The energy linearity and resolution of the calorimeter depend on the light yield uniformity of the sensitive medium. It is essential to qualify the entire detector production in order to select scintillator tiles with the uniformity of light yield within 10%. An automated batch test platform has been designed with 144 channels and an automated 3D servo motor. The paper summarizes the tests performed on more than 15000 scintillator tiles, and the SiPMs work at 59 V (overvoltage: 5 V). The measured light yield, corrected for the set-up response non-uniformity, is around 12.9 p.e. About 91.6% of scintillators (14219 pieces) are qualified within 10% of the light yield window.