Rong Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rong Zeng has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Sijia Hu
College of Electrical and Information Engineering, Hunan University, Changsha, China
3 shared publications - Yong Li
School of Mathematics, Jilin University, Changchun, China
3 shared publications - Chen Li
Center for Single-Cell Omics, School of Public Health, Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 shared publications - Jianping Guo
Institute of Precision Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publications - Jiarui Wu
Department of Clinical Chinese Pharmacy, School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing, China
2 shared publications - Junjie Zhao
Amgen 1 Oncology Research South San Francisco, California
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 6291-6304
Enhancing Resilience of Power Distribution Systems Under Cyber-Physical Hybrid Attacks: A Coordinated Localization and Restoration Strategy With Feeder Automation
The widespread deployment of distributed feeder automation (DFA) has increased the vulnerability of power distribution systems to cyber-physical hybrid attacks. To enhance the resilience of power distribution systems under hybrid attacks, this paper proposes a two-stage integrated cyber-physical system (TICPS) recovery strategy. This strategy integrates hybrid attack localization and isolation, and cyber-physical collaborative restoration, while effectively coordinating multiple resources. In the first stage, a hybrid attack localization module is developed, incorporating an attack descriptive model and a network equivalent transformation method to accurately locate cyber and physical attacks. The localization results are then used to guide DFA to isolate attacked agents and line faults resulting from the attacks. In the second stage, a grid reconfiguration and island formation module is first proposed to achieve efficient load restoration while considering the operational constraints of DFA under a compromised cyber layer. Subsequently, a repair crew dispatch module is designed to optimize crew routing based on value functions of cyber-physical faulty components, thereby facilitating complete cyber-physical system recovery. To leverage sequentially restored and controllable resources during the repair process, a repair event-triggered mechanism is introduced to coordinate grid reconfiguration and crew dispatch. The effectiveness and scalability of the proposed strategy are validated through simulations on the IEEE 33-bus and IEEE 123-bus systems, which demonstrate promising results.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 6291-6304
Enhancing Resilience of Power Distribution Systems Under Cyber-Physical Hybrid Attacks: A Coordinated Localization and Restoration Strategy With Feeder Automation
The widespread deployment of distributed feeder automation (DFA) has increased the vulnerability of power distribution systems to cyber-physical hybrid attacks. To enhance the resilience of power distribution systems under hybrid attacks, this paper proposes a two-stage integrated cyber-physical system (TICPS) recovery strategy. This strategy integrates hybrid attack localization and isolation, and cyber-physical collaborative restoration, while effectively coordinating multiple resources. In the first stage, a hybrid attack localization module is developed, incorporating an attack descriptive model and a network equivalent transformation method to accurately locate cyber and physical attacks. The localization results are then used to guide DFA to isolate attacked agents and line faults resulting from the attacks. In the second stage, a grid reconfiguration and island formation module is first proposed to achieve efficient load restoration while considering the operational constraints of DFA under a compromised cyber layer. Subsequently, a repair crew dispatch module is designed to optimize crew routing based on value functions of cyber-physical faulty components, thereby facilitating complete cyber-physical system recovery. To leverage sequentially restored and controllable resources during the repair process, a repair event-triggered mechanism is introduced to coordinate grid reconfiguration and crew dispatch. The effectiveness and scalability of the proposed strategy are validated through simulations on the IEEE 33-bus and IEEE 123-bus systems, which demonstrate promising results.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (5) , 4184-4196
Edge Resilient Control for Feeder Automation System Under Hybrid Attacks: A Hybrid Physical Model-Driven and Data-Driven Approach
The extensive application of the distributed feeder automation system (DFAs) is a prominent feature of the power distribution system (PDS). To enhance the resilience of DFAs to cyberattacks and hybrid attacks (contains both physical and cyber-attacks), this paper proposes an edge resilient control approach (ERCA) for DFAs, which integrates attack detection and mitigation. Two key modules are developed: 1) Edge Cyberattack Detection and Correction Module (ECDCM), achieving quick cyberattack detection and correction based on machine learning and physical constraints; 2) Consensus-based Fault Section Localization Module (CFSLM), which incorporates causality function related to agent overcurrent states and fault location to correctly localize the fault section in hybrid attack scenarios. In addition, the effective boundaries of ERCA are theoretically deduced in this paper, which proves that ERCA can retain resilience to cyberattacks and hybrid attacks even if undetected cyberattacks exist due to the failures of machine learning-based detection submodules. Finally, the proposal’s effectiveness and performance are tested and verified using the IEEE 123-bus system and the real two-feeder test platform with DFAs. By adopting ERCA, outages and load losses caused by cyber attacks are 100% avoided, and the fault caused by physical attack is correctly isolated with more than 97.6% reliability in 100,000 times-level Monte Carlo Numerical simulations of hybrid attacks.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (5) , 4184-4196
Edge Resilient Control for Feeder Automation System Under Hybrid Attacks: A Hybrid Physical Model-Driven and Data-Driven Approach
The extensive application of the distributed feeder automation system (DFAs) is a prominent feature of the power distribution system (PDS). To enhance the resilience of DFAs to cyberattacks and hybrid attacks (contains both physical and cyber-attacks), this paper proposes an edge resilient control approach (ERCA) for DFAs, which integrates attack detection and mitigation. Two key modules are developed: 1) Edge Cyberattack Detection and Correction Module (ECDCM), achieving quick cyberattack detection and correction based on machine learning and physical constraints; 2) Consensus-based Fault Section Localization Module (CFSLM), which incorporates causality function related to agent overcurrent states and fault location to correctly localize the fault section in hybrid attack scenarios. In addition, the effective boundaries of ERCA are theoretically deduced in this paper, which proves that ERCA can retain resilience to cyberattacks and hybrid attacks even if undetected cyberattacks exist due to the failures of machine learning-based detection submodules. Finally, the proposal’s effectiveness and performance are tested and verified using the IEEE 123-bus system and the real two-feeder test platform with DFAs. By adopting ERCA, outages and load losses caused by cyber attacks are 100% avoided, and the fault caused by physical attack is correctly isolated with more than 97.6% reliability in 100,000 times-level Monte Carlo Numerical simulations of hybrid attacks.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 8784-8796
Joint Optimal Charging Scheduling for Multiple EV Battery Swapping Stations Involving the Finite-State Modeling of Charging Bay
Battery swapping stations (BSSs) present a promising electric vehicle (EV) power supplement solution. However, the joint modeling and optimal scheduling for multiple BSSs is complex and rarely researched, especially when the idle state of charging bays (CBs) is non-negligible. In this article, for the distribution network (DN) with multiple BSSs, a joint optimal charging scheduling strategy considering the idle state of CB is developed to ensure the system’s safe operation and BSSs’ economic charging. In particular, a three-layered coupled model for multiple BSSs is constructed by modeling on the CB, BSS, and DN layers, which is used to visualize each BSS’s state quantity changes and their charging behaviors’ impacts on DN. To further improve the accuracy of this model, the CB’s idle state is given special consideration by developing a three-stage modeling method, which can detailedly describe the finite state transfer of CBs. In addition, to deal with the joint scheduling of multiple BSSs (JS-MBSS) problem upon the constructed model, a bi-level solving algorithm is proposed to convert the complex JS-MBSS into a solvable mixed integer quadratic constraint program (MIQCP). Finally, the proposed strategy and two others are verified via the modified IEEE 33-bus system. The results suggest that by adopting the proposed strategy, the total charging cost and the cumulative voltage fluctuation are reduced by 39.42% and 30.84%, respectively, which verifies the proposal’s positive benefits in stabilizing grid operation and enhancing the charging economy.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 8784-8796
Joint Optimal Charging Scheduling for Multiple EV Battery Swapping Stations Involving the Finite-State Modeling of Charging Bay
Battery swapping stations (BSSs) present a promising electric vehicle (EV) power supplement solution. However, the joint modeling and optimal scheduling for multiple BSSs is complex and rarely researched, especially when the idle state of charging bays (CBs) is non-negligible. In this article, for the distribution network (DN) with multiple BSSs, a joint optimal charging scheduling strategy considering the idle state of CB is developed to ensure the system’s safe operation and BSSs’ economic charging. In particular, a three-layered coupled model for multiple BSSs is constructed by modeling on the CB, BSS, and DN layers, which is used to visualize each BSS’s state quantity changes and their charging behaviors’ impacts on DN. To further improve the accuracy of this model, the CB’s idle state is given special consideration by developing a three-stage modeling method, which can detailedly describe the finite state transfer of CBs. In addition, to deal with the joint scheduling of multiple BSSs (JS-MBSS) problem upon the constructed model, a bi-level solving algorithm is proposed to convert the complex JS-MBSS into a solvable mixed integer quadratic constraint program (MIQCP). Finally, the proposed strategy and two others are verified via the modified IEEE 33-bus system. The results suggest that by adopting the proposed strategy, the total charging cost and the cumulative voltage fluctuation are reduced by 39.42% and 30.84%, respectively, which verifies the proposal’s positive benefits in stabilizing grid operation and enhancing the charging economy.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 301-312
Bi-Level Resilient Control Solution for Distributed Feeder Automation System Under Hybrid Attack
Distributed feeder automation system (DFAs), as a promising protection technology for power distribution system (PDS) with distributed generation, its vulnerability to cyberattacks and hybrid attacks (contains both physical and cyberattacks) is gradually recognized and haunts utilities, creating potential risks for its large-scale applications. This paper proposes a novel bilevel resilient control solution (BRCS) deployed to DFAs without hardware burden. Two key modules are developed: 1) Lightweight distributed cyberattack detection module (DCDM), deployed into agents of DFAs, based on unsupervised learning to realize the quick detection and reporting of cyberattacks; 2) Robust centralized fault section localization module (CFSLM), installed in DFAs’ host workstation located in control center, achieving the correctly fault section localization and the high dimensionally awareness of attack events in cyberattack and hybrid attack scenarios. By adopting BRCS, outages and load losses caused by cyberattacks can be 100% avoided, and faults caused by physical attacks can be correctly isolated at once. Finally, the effectiveness and performance of the proposal are verified and conducted by the real two-feeder test platform with DFAs. In this process, a digital high-dimensional awareness and control unit is created against cyber and hybrid attacks, contributing to the system-level application of risk management and resilient control.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 301-312
Bi-Level Resilient Control Solution for Distributed Feeder Automation System Under Hybrid Attack
Distributed feeder automation system (DFAs), as a promising protection technology for power distribution system (PDS) with distributed generation, its vulnerability to cyberattacks and hybrid attacks (contains both physical and cyberattacks) is gradually recognized and haunts utilities, creating potential risks for its large-scale applications. This paper proposes a novel bilevel resilient control solution (BRCS) deployed to DFAs without hardware burden. Two key modules are developed: 1) Lightweight distributed cyberattack detection module (DCDM), deployed into agents of DFAs, based on unsupervised learning to realize the quick detection and reporting of cyberattacks; 2) Robust centralized fault section localization module (CFSLM), installed in DFAs’ host workstation located in control center, achieving the correctly fault section localization and the high dimensionally awareness of attack events in cyberattack and hybrid attack scenarios. By adopting BRCS, outages and load losses caused by cyberattacks can be 100% avoided, and faults caused by physical attacks can be correctly isolated at once. Finally, the effectiveness and performance of the proposal are verified and conducted by the real two-feeder test platform with DFAs. In this process, a digital high-dimensional awareness and control unit is created against cyber and hybrid attacks, contributing to the system-level application of risk management and resilient control.
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
Supplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
Supplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
- Open Access
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
Supplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
- 3 April 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
Supplementary Figure from EXOC4 Promotes Diffuse-Type Gastric Cancer Metastasis via Activating FAK Signal
- Open Access
- 1 March 2023
- Published by Medknow in Journal of Translational Critical Care Medicine
- Vol. 5 (1)
Risk Factors and Prediction of Postoperative Delirium in Aortic Arch Replacement: A Retrospective Cohort Study
Objective: This study aimed to explore the risk factors and prediction of postoperative delirium (POD) in aortic arch replacement. Methods: The preoperative, intraoperative, and postoperative clinical data of patients undergoing aortic arch replacement in our hospital from January 1, 2018, to March 31, 2019, were retrospectively analyzed. According to whether POD occurred, cases were divided into delirium group and control group. The clinical data of the patients were firstly screened by univariate analysis, and then the meaningful variables were analyzed by multivariate logistic regression analysis. The receiver operating characteristic curve was used to analyze the meaningful factors in predicting the occurrence of POD after aortic arch replacement. Results: A total of 162 patients were included in the study. The prevalence of POD was 46.9% (n = 76). The results of univariate and multivariate analyses showed that the intraoperative minimum mean arterial pressure (MAP) (odds ratio [OR] = 0.635, 95% confidence interval [CI] = 0.5510.731, P < 0.001), postoperative C-reactive protein (OR = 1.010, 95% CI = 1.0031.018, P = 0.005), and postoperative infection (OR = 3.148, 95% CI = 1.1188.867, P = 0.030) were the independent risk factors for POD in aortic arch replacement. Among them, the intraoperative minimum MAP has the best prediction effect. When its cutoff value reaches ≤ 49 mmHg, the specificity for predicting POD is 84.88% and the sensitivity is 81.58%. Conclusions: A lower intraoperative minimum MAP is an independent risk factor and has the predictive value for POD in aortic arch replacement.
- 1 March 2023
- Published by Medknow in Journal of Translational Critical Care Medicine
- Vol. 5 (1)
Open AccessRisk Factors and Prediction of Postoperative Delirium in Aortic Arch Replacement: A Retrospective Cohort Study
Objective: This study aimed to explore the risk factors and prediction of postoperative delirium (POD) in aortic arch replacement. Methods: The preoperative, intraoperative, and postoperative clinical data of patients undergoing aortic arch replacement in our hospital from January 1, 2018, to March 31, 2019, were retrospectively analyzed. According to whether POD occurred, cases were divided into delirium group and control group. The clinical data of the patients were firstly screened by univariate analysis, and then the meaningful variables were analyzed by multivariate logistic regression analysis. The receiver operating characteristic curve was used to analyze the meaningful factors in predicting the occurrence of POD after aortic arch replacement. Results: A total of 162 patients were included in the study. The prevalence of POD was 46.9% (n = 76). The results of univariate and multivariate analyses showed that the intraoperative minimum mean arterial pressure (MAP) (odds ratio [OR] = 0.635, 95% confidence interval [CI] = 0.5510.731, P < 0.001), postoperative C-reactive protein (OR = 1.010, 95% CI = 1.0031.018, P = 0.005), and postoperative infection (OR = 3.148, 95% CI = 1.1188.867, P = 0.030) were the independent risk factors for POD in aortic arch replacement. Among them, the intraoperative minimum MAP has the best prediction effect. When its cutoff value reaches ≤ 49 mmHg, the specificity for predicting POD is 84.88% and the sensitivity is 81.58%. Conclusions: A lower intraoperative minimum MAP is an independent risk factor and has the predictive value for POD in aortic arch replacement.