APA. R. Vivekananda Pai

A. R. Vivekananda Pai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A. R. Vivekananda Pai has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Finisher Gentlefile brush, XP-endo Finisher and ultrasonic irrigation for the removal of calcium hydroxide paste from root canal

    by Ojaswini Pawar, Gurudutt Nayak, Drisya D. Nambiar, Sonam Bohra, Philip Pradeep, A. R. Vivekananda Pai, Ramanathan Ravi

    Eliminating residual calcium hydroxide [Ca(OH)2] intracanal medicament from the walls of a root canal presents a persistent obstacle that can impede the establishment of a proper fluid-tight seal during obturation. The effective removal of these medicaments from the canal walls has consistently posed a significant challenge. Consequently, several systems have been developed and assessed in order to address this issue. Therefore, it is of interest to compare the efficacy of Finisher Gentlefile Brush, XP-endo Finisher, and Passive Ultrasonic Irrigation (PUI) on the removal of an oil-based Ca(OH)2 paste. 60 human mandibular extracted premolars were selected and underwent preparation with Pro Taper Gold rotary file system till size F5. The canals were dried and filled with Metapex and stored for a week. Further, the specimens were divided into 3 groups depending upon the Metapex removal protocols, namely, Finisher Gentlefile Brush, XP-endo Finisher, and PUI. Afterward, the specimens were sectioned buccolingually. Evaluation of remnants was done with a scoring system under a dental microscope at 25x magnification. The data was analyzed using the Chi-square test (p<.05). With the exception of PUI, all the methods demonstrated significantly better performance, with Finisher Gentlefile Brush being the most effective across all canal thirds (p<.05). While none of the methods achieved complete cleanliness, Finisher Gentlefile Brush exhibited exceptional results compared to the other two systems employed.


  • Open Access

    Evaluation of apically extruded debris following glide-path preparation with different file systems

    by Gurudutt Nayak, Philip Pradeep, A. R. Vivekananda Pai, Neha Singh, Anik Banerjee, Chinmay Vartak, Rahul Sharma

    The amount of apically extruded debris following glide-path preparation of mesial root of 120 freshly extracted human mandibular molar teeth using Senseus ProFinder files, PathFile, G-Files, Scout-RaCe files, HyFlex glidepath files and V glide-path two file system is of interest. The Eppendorf tubes were used as test equipment for collecting debris and the average weight of the debris was measured using an electronic micro-balancing system. It was observed that regardless of the file system utilized, debris was expelled from the apex. The G files resulted in a lower quantity of debris being extruded (0.070 ą 0.002 mg). In contrast, the V glide-path two file system exhibited the highest amount of debris extrusion (0.110 ą 0.004 mg) compared to all other file systems.