Ping Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ping Chen has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Jinshou Tian
6 shared publications- Luanxuan He
Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Information Avenue 17, 710119 Xi'an, China
6 shared publications - Shengli Wu
Key Laboratory for Physical Electronics and Devices of the Ministry of Education, School of Electronic Science and Engineering, Xi'an Jiaotong University, Xi'an 710049, China
6 shared publications Hulin Liu
5 shared publications- Kuinian Li
State Key Laboratory of Ultrafast Optical Science and Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China
5 shared publications Yonglin Wei
5 shared publications
Latest Publications
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
A gated alpha-particle time-of-flight spectrometer for laser-driven proton-boron fusion reactions.
A gated scintillator-based α-particle time-of-flight (αTOF) spectrometer is developed for real-time diagnosis of nuclear reaction products in harsh laser-plasma experiments. The system employs fast-response EJ-204 plastic scintillator coupled with a gated microchannel plate photomultiplier tube and uses gating technique to suppress intense prompt x/γ-ray and relativistic electron radiation backgrounds. Calibration experiments are performed using 100-250 keV protons and 100-300 keV α-particle beams from a 320 kV high-voltage platform. The measured response efficiency increases linearly with particle energy and agrees well with theoretical calculations based on the ionization quenching model. The spectrometer is validated in laser-driven proton-boron fusion experiments at the XG-III laser facility, where a distinct α-particle peak at 3.65 MeV from the dominant 11B(p, α1)8Be* reaction channel is clearly resolved. The results demonstrate that the αTOF spectrometer enables real-time, shot-to-shot acquisition of energy spectra and yield measurements of α particles in high-radiation harsh environments. This work provides a robust online diagnostic tool for laser-driven nuclear reaction studies, with future improvements aimed at extending MeV energy calibration and developing multiplexed detection systems for quantitative yield measurements.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
A gated alpha-particle time-of-flight spectrometer for laser-driven proton-boron fusion reactions.
A gated scintillator-based α-particle time-of-flight (αTOF) spectrometer is developed for real-time diagnosis of nuclear reaction products in harsh laser-plasma experiments. The system employs fast-response EJ-204 plastic scintillator coupled with a gated microchannel plate photomultiplier tube and uses gating technique to suppress intense prompt x/γ-ray and relativistic electron radiation backgrounds. Calibration experiments are performed using 100-250 keV protons and 100-300 keV α-particle beams from a 320 kV high-voltage platform. The measured response efficiency increases linearly with particle energy and agrees well with theoretical calculations based on the ionization quenching model. The spectrometer is validated in laser-driven proton-boron fusion experiments at the XG-III laser facility, where a distinct α-particle peak at 3.65 MeV from the dominant 11B(p, α1)8Be* reaction channel is clearly resolved. The results demonstrate that the αTOF spectrometer enables real-time, shot-to-shot acquisition of energy spectra and yield measurements of α particles in high-radiation harsh environments. This work provides a robust online diagnostic tool for laser-driven nuclear reaction studies, with future improvements aimed at extending MeV energy calibration and developing multiplexed detection systems for quantitative yield measurements.
- 28 October 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1083
Simulation and experimental investigation of anode secondary emission and readout effects in microchannel plate photomultipliers
- 28 October 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1083
Simulation and experimental investigation of anode secondary emission and readout effects in microchannel plate photomultipliers
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Calibration of a gated neutron time-of-flight spectrometer with low-afterglow
Neutron Time-of-Flight (nTOF) detectors are key diagnostics to detect thermonuclear neutrons in laser-fusion experiments. This diagnostic, however, is often plagued by strong gamma-ray noise prior to neutron signals, especially in harsh fast-ignition (FI) environments. To address this issue, a combination of low-afterglow liquid scintillators with time-gated photomultiplier tubes as necessary nTOF components would be a natural solution. However, the calibration of such detectors is challenging due to low detection efficiency and low neutron yield in FI experiments. In this paper, we propose a novel method to cross-calibrate a gated low-afterglow nTOF spectrometer using a pre-calibrated traditional non-gated nTOF spectrometer. This approach was demonstrated using neutrons from counter-streaming deuterated-polystyrene plasmas driven by the ShenGuang-II (SG-II) laser facility, with neutron yields ranging from 4 × 105 to 1 × 107. By implementing this calibration method, we anticipate a significant improvement in the accuracy of neutron detection within a 10% uncertainty for double-cone ignition experiments.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Calibration of a gated neutron time-of-flight spectrometer with low-afterglow
Neutron Time-of-Flight (nTOF) detectors are key diagnostics to detect thermonuclear neutrons in laser-fusion experiments. This diagnostic, however, is often plagued by strong gamma-ray noise prior to neutron signals, especially in harsh fast-ignition (FI) environments. To address this issue, a combination of low-afterglow liquid scintillators with time-gated photomultiplier tubes as necessary nTOF components would be a natural solution. However, the calibration of such detectors is challenging due to low detection efficiency and low neutron yield in FI experiments. In this paper, we propose a novel method to cross-calibrate a gated low-afterglow nTOF spectrometer using a pre-calibrated traditional non-gated nTOF spectrometer. This approach was demonstrated using neutrons from counter-streaming deuterated-polystyrene plasmas driven by the ShenGuang-II (SG-II) laser facility, with neutron yields ranging from 4 × 105 to 1 × 107. By implementing this calibration method, we anticipate a significant improvement in the accuracy of neutron detection within a 10% uncertainty for double-cone ignition experiments.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07010
Design of high gain discrete dynode electron multiplier
This study focuses on the optimization of discrete dynode electron multipliers (DEMs), which are critical for high-sensitivity signal detection in applications such as particle physics, nuclear reaction monitoring, and medical imaging. The research employs CST Studio Suite® electromagnetic simulations to analyze the impact of structural parameters — such as inter-dynode voltages, incidence angles, and surface coatings — on electron trajectory dynamics and multiplication efficiency. A 26-stage MgO dynode array is simulated, featuring dual output modes (analog and pulse counting) to accommodate varying ion input densities. The optimization process identifies key geometric parameters, including dynode spacing, curvature, and alignment, that significantly influence gain performance. The optimized design achieves a simulated gain of 1.8×105 in analog mode and 5.5×107 in pulse-counting mode, representing substantial improvements over baseline configurations. Experimental validation confirms the simulation trends, though discrepancies due to material degradation during assembly are noted. This work provides actionable insights for the design and optimization of high-performance DEMs, addressing challenges in achieving stable, high-gain operation over extended periods.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07010
Design of high gain discrete dynode electron multiplier
This study focuses on the optimization of discrete dynode electron multipliers (DEMs), which are critical for high-sensitivity signal detection in applications such as particle physics, nuclear reaction monitoring, and medical imaging. The research employs CST Studio Suite® electromagnetic simulations to analyze the impact of structural parameters — such as inter-dynode voltages, incidence angles, and surface coatings — on electron trajectory dynamics and multiplication efficiency. A 26-stage MgO dynode array is simulated, featuring dual output modes (analog and pulse counting) to accommodate varying ion input densities. The optimization process identifies key geometric parameters, including dynode spacing, curvature, and alignment, that significantly influence gain performance. The optimized design achieves a simulated gain of 1.8×105 in analog mode and 5.5×107 in pulse-counting mode, representing substantial improvements over baseline configurations. Experimental validation confirms the simulation trends, though discrepancies due to material degradation during assembly are noted. This work provides actionable insights for the design and optimization of high-performance DEMs, addressing challenges in achieving stable, high-gain operation over extended periods.
- 30 September 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
- Vol. 39 (26n27)
Research progress on long lifetime MCP-PMT for the DTOF detector in STCF
The Super Tau Charm Facility (STCF) is a state-of-the-art electron-positron collider operating in the center-of-mass energy range of 2–7[ ]GeV and achieving a peak luminosity of more than [ ][ ]cm−2s−1, which is pivotal for advancing particle physics research. The DIRC-like time-of-flight (DTOF) detector is one of the crucial components of the STCF, designed to identify high-momentum charged particles with high precision. A significant element of the DTOF is the microchannel plate photomultiplier tube (MCP-PMT), known for its exceptional time resolution in the detection of Cherenkov light. With the STCF expected to operate for over a decade, stringent requirements are imposed on the MCP-PMT, requiring an integrated anode charge (IAC) in excess of 10[ ]C/cm2. In this paper, the lifetime of the single anode MCP-PMT prototypes is investigated and a multi-anode MCP-PMT design is presented. The results show that the lifetime of the single anode MCP-PMT is greater than 11[ ]C/cm2 when a 6 nm-thick ALD layer is deposited on the inner surface of the MCP and an electron scrubbing dosage of 0.75[ ][ ]A[ ][ ][ ]h/cm2 is applied to the MCP. The lifetime is expected to be further improved by increasing the electron scrubbing dosage and optimizing the ALD layer. The studies on the single anode MCP-PMTs will be applied to the development of the long-life multi-anode MCP-PMT.
- 30 September 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
- Vol. 39 (26n27)
Research progress on long lifetime MCP-PMT for the DTOF detector in STCF
The Super Tau Charm Facility (STCF) is a state-of-the-art electron-positron collider operating in the center-of-mass energy range of 2–7[ ]GeV and achieving a peak luminosity of more than [ ][ ]cm−2s−1, which is pivotal for advancing particle physics research. The DIRC-like time-of-flight (DTOF) detector is one of the crucial components of the STCF, designed to identify high-momentum charged particles with high precision. A significant element of the DTOF is the microchannel plate photomultiplier tube (MCP-PMT), known for its exceptional time resolution in the detection of Cherenkov light. With the STCF expected to operate for over a decade, stringent requirements are imposed on the MCP-PMT, requiring an integrated anode charge (IAC) in excess of 10[ ]C/cm2. In this paper, the lifetime of the single anode MCP-PMT prototypes is investigated and a multi-anode MCP-PMT design is presented. The results show that the lifetime of the single anode MCP-PMT is greater than 11[ ]C/cm2 when a 6 nm-thick ALD layer is deposited on the inner surface of the MCP and an electron scrubbing dosage of 0.75[ ][ ]A[ ][ ][ ]h/cm2 is applied to the MCP. The lifetime is expected to be further improved by increasing the electron scrubbing dosage and optimizing the ALD layer. The studies on the single anode MCP-PMTs will be applied to the development of the long-life multi-anode MCP-PMT.