Lingmei Niu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lingmei Niu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Meng Jiang
School of Public Health, Hebei Medical University, Shijiazhuang, PR China
5 shared publicationsWen Yan
School of Public Health, Hebei Medical University, Shijiazhuang, PR China
5 shared publicationsYan Jin
School of Public Health, Hebei Medical University, Shijiazhuang, PR China
5 shared publicationsYipeng Wang
School of Public Health, Hebei Medical University, Shijiazhuang, PR China
4 shared publicationsJingyi Wang
School of Public Health, Hebei Medical University, Shijiazhuang, PR China
3 shared publicationsKejia Xu
School of Public Health, Hebei Medical University, Shijiazhuang, PR China
3 shared publications
Latest Publications
- Open Access
- 22 January 2026
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 19, 3842025
Design of a label-free mass sensor based on three-dimensional nanomagnetic bead for ultrasensitive detection of cardiac troponin I
In this research, an innovative and highly sensitive mass sensor was designed for cardiac troponin I (cTnI) detection based on 3D nanomagnetic beads, which do not need to be labelled using signal probes. The proposed sensor was characterized by several technologies, such as transmission electron microscopy (TEM), UV-visible spectrophotometry, atomic force microscopy (AFM), Fourier transform infrared spectrometer (FTIR), scanning electron microscope (SEM), etc. Under optimum conditions, the frequency showed a remarkable linear dependence on cTnI concentration within the interval of 1.0 pg mL -1 to 10.0 ng mL -1 , with a detection limit of 0.2 pg mL -1 . This biosensor showed ultrasensitivity, time-efficiency, and lower costs, and consequently can be expected to be applied in real life.
- 22 January 2026
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 19, 3842025
Open AccessDesign of a label-free mass sensor based on three-dimensional nanomagnetic bead for ultrasensitive detection of cardiac troponin I
In this research, an innovative and highly sensitive mass sensor was designed for cardiac troponin I (cTnI) detection based on 3D nanomagnetic beads, which do not need to be labelled using signal probes. The proposed sensor was characterized by several technologies, such as transmission electron microscopy (TEM), UV-visible spectrophotometry, atomic force microscopy (AFM), Fourier transform infrared spectrometer (FTIR), scanning electron microscope (SEM), etc. Under optimum conditions, the frequency showed a remarkable linear dependence on cTnI concentration within the interval of 1.0 pg mL -1 to 10.0 ng mL -1 , with a detection limit of 0.2 pg mL -1 . This biosensor showed ultrasensitivity, time-efficiency, and lower costs, and consequently can be expected to be applied in real life.
- 17 June 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 166, 109035
17β-Estradiol point-of-care test by commercial pregnancy test strips based on target-triggered CRISPR/Cas12a cleavage activity
- 17 June 2025
- Published by Elsevier in Bioelectrochemistry
- Vol. 166, 109035
17β-Estradiol point-of-care test by commercial pregnancy test strips based on target-triggered CRISPR/Cas12a cleavage activity
- Open Access
- 15 May 2025
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 18, 1782024-9
A glucometer-colorimetric dual mode biosensor for point-of-care testing of cardiac troponin I
CTnI is considered the primary marker for the diagnosis of Acute myocardial infarction (AMI).. At present, cTnI relies on laboratory testing, which requires technical personnel and specialized equipment. This strategy proposes a dual-mode sensor based on a blood glucose meter and colorimetry to achieve portable, rapid, and accurate measurement of cTnI. The feasibility of this sensor was validated using UV spectrophotometry and polyacrylamide gel electrophoresis. Under optimal conditions, the linear ranges for the glucometer and colorimetric modes were 0.01 ngmL-1 to 20.0 ngmL-1 and 0.03 ngmL-1 to 15.0 ngmL-1, with detection limits of 0.001 ngmL-1 and 0.005 ngmL-1, respectively. The dual-mode sensor exhibits high sensitivity and selectivity, enabling rapid portable dual-mode detection. This method has been successfully applied for detecting cTnI in human serum, indicating significant potential for clinical applications.
- 15 May 2025
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 18, 1782024-9
Open AccessA glucometer-colorimetric dual mode biosensor for point-of-care testing of cardiac troponin I
CTnI is considered the primary marker for the diagnosis of Acute myocardial infarction (AMI).. At present, cTnI relies on laboratory testing, which requires technical personnel and specialized equipment. This strategy proposes a dual-mode sensor based on a blood glucose meter and colorimetry to achieve portable, rapid, and accurate measurement of cTnI. The feasibility of this sensor was validated using UV spectrophotometry and polyacrylamide gel electrophoresis. Under optimal conditions, the linear ranges for the glucometer and colorimetric modes were 0.01 ngmL-1 to 20.0 ngmL-1 and 0.03 ngmL-1 to 15.0 ngmL-1, with detection limits of 0.001 ngmL-1 and 0.005 ngmL-1, respectively. The dual-mode sensor exhibits high sensitivity and selectivity, enabling rapid portable dual-mode detection. This method has been successfully applied for detecting cTnI in human serum, indicating significant potential for clinical applications.
- 3 January 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (5) , 999-1009
Research on a molecularly imprinted electrochemical sensor based on a graphene quantum dot-gold nanoparticle composite for the determination of 17β-estradiol
In this study, a molecularly imprinted electrochemical sensor (MIECS) was constructed based on the combination of graphene quantum dots-gold nanoparticles (GQDs-AuNPs), molecular imprinting polymer (MIP), and electrochemical technology for the ultra-sensitive detection of 17β-estradiol (E2). GQDs-AuNPs were synthesized and modified on the surface of glassy carbon electrodes (GCE). Safranine T was used as the functional monomer and E2 was the template molecule for self-assembly and electropolymerization, thus generating an MIP film on the electrode surface. By elution, a large number of recognition sites for E2 were left in the polymer matrix. Before and after the combination with the target, there is an obvious change in the peak current signal, which enables the quantitative detection of E2 to be achieved. Under the optimized conditions, the concentration of E2 showed a good linear relationship with the peak current of the sensor in the range of 1 × 10−5–1 × 10−14 M, and the detection limit was 2.2 fM. The molecularly imprinted electrochemical sensor based on GQDs-AuNPs established in this study offers the features of simplicity of operation, low experimental cost, and high sensitivity. This method successfully detected E2 in milk, urine, and human serum, demonstrating its potential for broad application in clinical practice.
- 3 January 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (5) , 999-1009
Research on a molecularly imprinted electrochemical sensor based on a graphene quantum dot-gold nanoparticle composite for the determination of 17β-estradiol
In this study, a molecularly imprinted electrochemical sensor (MIECS) was constructed based on the combination of graphene quantum dots-gold nanoparticles (GQDs-AuNPs), molecular imprinting polymer (MIP), and electrochemical technology for the ultra-sensitive detection of 17β-estradiol (E2). GQDs-AuNPs were synthesized and modified on the surface of glassy carbon electrodes (GCE). Safranine T was used as the functional monomer and E2 was the template molecule for self-assembly and electropolymerization, thus generating an MIP film on the electrode surface. By elution, a large number of recognition sites for E2 were left in the polymer matrix. Before and after the combination with the target, there is an obvious change in the peak current signal, which enables the quantitative detection of E2 to be achieved. Under the optimized conditions, the concentration of E2 showed a good linear relationship with the peak current of the sensor in the range of 1 × 10−5–1 × 10−14 M, and the detection limit was 2.2 fM. The molecularly imprinted electrochemical sensor based on GQDs-AuNPs established in this study offers the features of simplicity of operation, low experimental cost, and high sensitivity. This method successfully detected E2 in milk, urine, and human serum, demonstrating its potential for broad application in clinical practice.
- 11 October 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (45) , 7699-7709
Application of a metabolomics method in the study of pear fruit storage
The entire transportation process of ‘crown’ pears from harvest to consumption is primarily refrigerated.
- 11 October 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (45) , 7699-7709
Application of a metabolomics method in the study of pear fruit storage
The entire transportation process of ‘crown’ pears from harvest to consumption is primarily refrigerated.