Yahya Kurdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yahya Kurdi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Igor Vladimirovich Reshetov
I.M. Sechenov First Moscow State Medical University (Sechenov University), Ministry of Health of Russia
5 shared publications - Feryal Kurdi
I.M. Sechenov First Moscow State Medical University (Sechenov University), Ministry of Health of the Russian Federation, Moscow, Russian Federation
4 shared publications - Andrey L. Istranov
I.M. Sechenov First Moscow State Medical University, Ministry of Health of Russia
2 shared publications - Artem Shiryaev
Levshin Institute of Cluster Oncology, University Clinical Hospital no. 1, Sechenov First Moscow State Medical University, Ministry of Health of the Russian Federation, 119435 University, Moscow, Russian Federation
2 shared publications - M. Kurdi
Peoples’ Friendship University of Russia named after Patrice Lumumba
2 shared publications - N. S. Sukortseva
I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University)
2 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Tomsk Cancer Research Institute in Siberian journal of oncology
- Vol. 25 (4) , 173-182
Delayed dual-tracer sentinel lymph node biopsy after nipple-sparing mastectomy with implant-based reconstruction
Objective: to present a clinical case of delayed dual-tracer sentinel lymph node biopsy using technetium-99m radiocolloid and indocyanine green fluorescence in a patient who previously underwent nipple-sparing mastectomy with immediate implant-based breast reconstruction, and to analyze the technical feasibility and early perioperative safety of the procedure. Material and Methods. This article presents a clinical case of delayed sentinel lymph node biopsy after previous nipple-sparing mastectomy with immediate implant-based breast reconstruction. The report is descriptive and was not intended to assess diagnostic accuracy, sensitivity, specificity, or the false-negative rate of the technique. A 40-year-old woman with a history of right nipple-sparing mastectomy and immediate implant-based reconstruction underwent delayed axillary sentinel lymph node biopsy for staging regional lymphatic basin. Preoperative lymphatic mapping was performed using periareolar subcutaneous injection of 50 MBq 99m Tc-Nanocoll, followed by lymphoscintigraphy and SPECT-CT. On the day of surgery, indocyanine green was injected intradermally at four periareolar points. intraoperative detection was performed using a near-infrared fluorescence imaging system, MARS, version 2.0.0.7, 2024, and a handheld gamma probe. The primary procedural endpoint was technical success, defined as intraoperative identification and excision of at least one sentinel lymph node. Results. Preoperative lymphoscintigraphy and SPECT-CT demonstrated radiotracer uptake in two right axillary lymph nodes. Intraoperatively, both sentinel lymph nodes were successfully identified and excised using combined gamma-probe detection and fluorescence guidance. Concordance between radioactive and fluorescent signals was observed in both removed nodes. Histological examination showed no metastatic involvement. No intraoperative or early postoperative complications were recorded. The implant, mastectomy flaps and nipple-areolar complex remained viable, with no evidence of ischemia, infection, implant exposure or reconstructive failure. Conclusion. In this clinical case, delayed dual-tracer sentinel lymph node biopsy was technically successful and was not associated with early perioperative complications. These findings indicate the principal technical feasibility of the procedure in this specific clinical situation, but they do not allow assessment of diagnostic accuracy, reproducibility, or oncological safety.
- 21 September 2026
- Published by Tomsk Cancer Research Institute in Siberian journal of oncology
- Vol. 25 (4) , 173-182
Open AccessDelayed dual-tracer sentinel lymph node biopsy after nipple-sparing mastectomy with implant-based reconstruction
Objective: to present a clinical case of delayed dual-tracer sentinel lymph node biopsy using technetium-99m radiocolloid and indocyanine green fluorescence in a patient who previously underwent nipple-sparing mastectomy with immediate implant-based breast reconstruction, and to analyze the technical feasibility and early perioperative safety of the procedure. Material and Methods. This article presents a clinical case of delayed sentinel lymph node biopsy after previous nipple-sparing mastectomy with immediate implant-based breast reconstruction. The report is descriptive and was not intended to assess diagnostic accuracy, sensitivity, specificity, or the false-negative rate of the technique. A 40-year-old woman with a history of right nipple-sparing mastectomy and immediate implant-based reconstruction underwent delayed axillary sentinel lymph node biopsy for staging regional lymphatic basin. Preoperative lymphatic mapping was performed using periareolar subcutaneous injection of 50 MBq 99m Tc-Nanocoll, followed by lymphoscintigraphy and SPECT-CT. On the day of surgery, indocyanine green was injected intradermally at four periareolar points. intraoperative detection was performed using a near-infrared fluorescence imaging system, MARS, version 2.0.0.7, 2024, and a handheld gamma probe. The primary procedural endpoint was technical success, defined as intraoperative identification and excision of at least one sentinel lymph node. Results. Preoperative lymphoscintigraphy and SPECT-CT demonstrated radiotracer uptake in two right axillary lymph nodes. Intraoperatively, both sentinel lymph nodes were successfully identified and excised using combined gamma-probe detection and fluorescence guidance. Concordance between radioactive and fluorescent signals was observed in both removed nodes. Histological examination showed no metastatic involvement. No intraoperative or early postoperative complications were recorded. The implant, mastectomy flaps and nipple-areolar complex remained viable, with no evidence of ischemia, infection, implant exposure or reconstructive failure. Conclusion. In this clinical case, delayed dual-tracer sentinel lymph node biopsy was technically successful and was not associated with early perioperative complications. These findings indicate the principal technical feasibility of the procedure in this specific clinical situation, but they do not allow assessment of diagnostic accuracy, reproducibility, or oncological safety.
- Open Access
Indocyanine Green Fluorescence-Guided Sentinel Lymph Node Biopsy in Breast Cancer Using the MARS Near-Infrared Imaging System: A Prospective Single-Center Feasibility Study
Background: Sentinel lymph node biopsy (SLNB) is an essential component of axillary staging in breast cancer. Fluorescence-guided mapping with indocyanine green (ICG) enables real-time visualization of lymphatic drainage; however, the parameters of fluorescence-signal recording require standardization. Objective: To assess the technical feasibility and clinical applicability of SLNB with ICG under near-infrared (NIR) imaging guidance in patients with breast cancer. Materials and Methods: This prospective single-center study included 30 patients who underwent ICG-guided SLNB between 2023 and 2025. In 24 patients, ICG mapping was combined with technetium-99m radioisotope navigation; in 6 patients, ICG guidance alone was used. The protocol comprised periareolar ICG injection, standardized imaging conditions, and fluorescence-index recording. Results: The protocol was completed in all 30 patients. Fluorescent visualization of the lymphatic pathway and/or the sentinel lymph node (SLN) was achieved in every case, and no ICG-related adverse reactions were recorded. The mean fluorescence index was 213.0 ± 24.7, the median was 206.0 [192.5–237.2], and the min–max was 180–255. Conclusion: SLNB with ICG under NIR imaging guidance demonstrated technical feasibility in a prospective single-center cohort. Quantitative fluorescence-index recording may serve as a component of standardizing intraoperative fluorescence guidance.
Open AccessIndocyanine Green Fluorescence-Guided Sentinel Lymph Node Biopsy in Breast Cancer Using the MARS Near-Infrared Imaging System: A Prospective Single-Center Feasibility Study
Background: Sentinel lymph node biopsy (SLNB) is an essential component of axillary staging in breast cancer. Fluorescence-guided mapping with indocyanine green (ICG) enables real-time visualization of lymphatic drainage; however, the parameters of fluorescence-signal recording require standardization. Objective: To assess the technical feasibility and clinical applicability of SLNB with ICG under near-infrared (NIR) imaging guidance in patients with breast cancer. Materials and Methods: This prospective single-center study included 30 patients who underwent ICG-guided SLNB between 2023 and 2025. In 24 patients, ICG mapping was combined with technetium-99m radioisotope navigation; in 6 patients, ICG guidance alone was used. The protocol comprised periareolar ICG injection, standardized imaging conditions, and fluorescence-index recording. Results: The protocol was completed in all 30 patients. Fluorescent visualization of the lymphatic pathway and/or the sentinel lymph node (SLN) was achieved in every case, and no ICG-related adverse reactions were recorded. The mean fluorescence index was 213.0 ± 24.7, the median was 206.0 [192.5–237.2], and the min–max was 180–255. Conclusion: SLNB with ICG under NIR imaging guidance demonstrated technical feasibility in a prospective single-center cohort. Quantitative fluorescence-index recording may serve as a component of standardizing intraoperative fluorescence guidance.
- Open Access
- 6 January 2025
- Published by JMIR Publications Inc. in JMIRx Med
- Vol. 6 (1) , e68769
Authors’ Response to Peer Reviews of “Applications of Indocyanine Green in Breast Cancer for Sentinel Lymph Node Mapping: Protocol for a Scoping Review”
- 6 January 2025
- Published by JMIR Publications Inc. in JMIRx Med
- Vol. 6 (1) , e68769
Open AccessAuthors’ Response to Peer Reviews of “Applications of Indocyanine Green in Breast Cancer for Sentinel Lymph Node Mapping: Protocol for a Scoping Review”
- Open Access
- 6 January 2025
- Published by JMIR Publications Inc. in JMIRx Med
- Vol. 6 (1) , e66213
Applications of Indocyanine Green in Breast Cancer for Sentinel Lymph Node Mapping: Protocol for a Scoping Review
Introduction: Breast cancer is the leading cause of morbidity and mortality worldwide. Accurate sentinel lymph node (SLN) mapping is crucial for staging and treatment planning in early-stage breast cancer. Indocyanine green (ICG) has emerged as a promising agent for fluorescence imaging in SLN mapping. However, comprehensive assessment of its clinical utility, including accuracy and adverse effects, remains limited. This scoping review aims to consolidate evidence on the use of ICG in breast cancer SLN mapping. Objective: The objective of this scoping review is to evaluate the current literature on the use of ICG in SLN mapping for patients with breast cancer. This review aims to assess the accuracy, efficacy, and safety of ICG in this context and to identify gaps in the existing research. The outcomes will contribute to the development of further research as part of a PhD project. Methods: Five electronic databases will be searched (PubMed, Embase, MEDLINE, Web of Science, and Scopus) using search strategies developed in consultation with an academic supervisor. The search strategy is set to human studies published in English within the last 11 years. All retrieved citations will be imported to Zotero and then uploaded to Covidence for the screening of titles, abstracts, and full text according to prespecified inclusion criteria. Patients with early-stage breast cancer (T1 and T2), selected T3 cases where the SLN biopsy is accurate, and those with clinically node-negative breast cancer will be included. The intervention criterion includes studies using ICG for SLN mapping and studies on the assessment of fluorescence imaging cameras. Citations meeting the inclusion criteria for full-text review will have their data extracted by 2 independent reviewers, with disagreements resolved by discussion. A data extraction tool will be developed to capture full details about the participants, concept, and context, and findings relevant to the scoping review will be summarized. Results: The preliminary search began in December 2023. As of September 2024, papers have been screened and data are currently being extracted. Out of the 2130 references initially imported, 126 studies met the inclusion criteria after screening. The scoping review is expected to be published in January 2025. Conclusions: Although ICG technology has been used for SLN mapping in patients with breast cancer, initial searches in 2022 revealed limited data on this technique’s feasibility, safety, and effectiveness. At that time, preliminary search of Scopus, MEDLINE, Embase, and PubMed identified no current or forthcoming systematic reviews or scoping reviews on the topic. However, recent searches indicate a substantial increase in research and reviews, reflecting a growing interest and evidence in this area.
- 6 January 2025
- Published by JMIR Publications Inc. in JMIRx Med
- Vol. 6 (1) , e66213
Open AccessApplications of Indocyanine Green in Breast Cancer for Sentinel Lymph Node Mapping: Protocol for a Scoping Review
Introduction: Breast cancer is the leading cause of morbidity and mortality worldwide. Accurate sentinel lymph node (SLN) mapping is crucial for staging and treatment planning in early-stage breast cancer. Indocyanine green (ICG) has emerged as a promising agent for fluorescence imaging in SLN mapping. However, comprehensive assessment of its clinical utility, including accuracy and adverse effects, remains limited. This scoping review aims to consolidate evidence on the use of ICG in breast cancer SLN mapping. Objective: The objective of this scoping review is to evaluate the current literature on the use of ICG in SLN mapping for patients with breast cancer. This review aims to assess the accuracy, efficacy, and safety of ICG in this context and to identify gaps in the existing research. The outcomes will contribute to the development of further research as part of a PhD project. Methods: Five electronic databases will be searched (PubMed, Embase, MEDLINE, Web of Science, and Scopus) using search strategies developed in consultation with an academic supervisor. The search strategy is set to human studies published in English within the last 11 years. All retrieved citations will be imported to Zotero and then uploaded to Covidence for the screening of titles, abstracts, and full text according to prespecified inclusion criteria. Patients with early-stage breast cancer (T1 and T2), selected T3 cases where the SLN biopsy is accurate, and those with clinically node-negative breast cancer will be included. The intervention criterion includes studies using ICG for SLN mapping and studies on the assessment of fluorescence imaging cameras. Citations meeting the inclusion criteria for full-text review will have their data extracted by 2 independent reviewers, with disagreements resolved by discussion. A data extraction tool will be developed to capture full details about the participants, concept, and context, and findings relevant to the scoping review will be summarized. Results: The preliminary search began in December 2023. As of September 2024, papers have been screened and data are currently being extracted. Out of the 2130 references initially imported, 126 studies met the inclusion criteria after screening. The scoping review is expected to be published in January 2025. Conclusions: Although ICG technology has been used for SLN mapping in patients with breast cancer, initial searches in 2022 revealed limited data on this technique’s feasibility, safety, and effectiveness. At that time, preliminary search of Scopus, MEDLINE, Embase, and PubMed identified no current or forthcoming systematic reviews or scoping reviews on the topic. However, recent searches indicate a substantial increase in research and reviews, reflecting a growing interest and evidence in this area.
- Open Access
Applications of ICG in Breast Cancer for Sentinel Lymph Node Mapping: A Scoping Review Protocol
Objective: The objective of this scoping review is to evaluate the current literature on the use of Indocyanine Green (ICG) in sentinel lymph node (SLN) mapping for breast cancer patients. This review aims to assess the accuracy, efficacy, and safety of ICG in this context and to identify gaps in the existing research. The outcomes will contribute to the development of further research as part of a PhD project. Introduction: Breast cancer is the leading cause of morbidity and mortality worldwide. Accurate SLN mapping is crucial for staging and treatment planning in early-stage breast cancer. ICG has emerged as a promising agent for fluorescence imaging in SLN mapping. However, comprehensive assessment of its clinical utility, including accuracy and adverse effects, remains limited. This scoping review aims to consolidate evidence on the use of ICG in breast cancer SLN mapping. Inclusion criteria: Patients with early-stage breast cancer (T1, T2), selected T3 cases where sentinel lymph node biopsy is accurate, and clinically node-negative breast cancer. The intervention includes studies using ICG for SLN mapping and assessment of fluorescence imaging cameras. Methods: Five electronic databases will be searched (PubMed, EMBASE, MEDLINE, Web of Science, and SCOPUS) using search strategies developed in consultation with the academic supervisor. The search strategy is set to human studies published in English within the last 11 years. All retrieved citations will be imported to Zotero and then uploaded to Covidence for screening of titles, abstracts, and full text according to pre-specified inclusion criteria. Citations meeting the inclusion criteria for full-text review will have their data extracted by two independent reviewers, with disagreements resolved by discussion. A data extraction tool will be developed to capture full details about the participants, concept, and context, and findings relevant to the scoping review will be summarized. Keywords: Indocyanine Green, ICG, Sentinel Lymph Node, Breast Cancer, Fluorescence, Axillary Lymph Node Mapping, NIR
Open AccessApplications of ICG in Breast Cancer for Sentinel Lymph Node Mapping: A Scoping Review Protocol
Objective: The objective of this scoping review is to evaluate the current literature on the use of Indocyanine Green (ICG) in sentinel lymph node (SLN) mapping for breast cancer patients. This review aims to assess the accuracy, efficacy, and safety of ICG in this context and to identify gaps in the existing research. The outcomes will contribute to the development of further research as part of a PhD project. Introduction: Breast cancer is the leading cause of morbidity and mortality worldwide. Accurate SLN mapping is crucial for staging and treatment planning in early-stage breast cancer. ICG has emerged as a promising agent for fluorescence imaging in SLN mapping. However, comprehensive assessment of its clinical utility, including accuracy and adverse effects, remains limited. This scoping review aims to consolidate evidence on the use of ICG in breast cancer SLN mapping. Inclusion criteria: Patients with early-stage breast cancer (T1, T2), selected T3 cases where sentinel lymph node biopsy is accurate, and clinically node-negative breast cancer. The intervention includes studies using ICG for SLN mapping and assessment of fluorescence imaging cameras. Methods: Five electronic databases will be searched (PubMed, EMBASE, MEDLINE, Web of Science, and SCOPUS) using search strategies developed in consultation with the academic supervisor. The search strategy is set to human studies published in English within the last 11 years. All retrieved citations will be imported to Zotero and then uploaded to Covidence for screening of titles, abstracts, and full text according to pre-specified inclusion criteria. Citations meeting the inclusion criteria for full-text review will have their data extracted by two independent reviewers, with disagreements resolved by discussion. A data extraction tool will be developed to capture full details about the participants, concept, and context, and findings relevant to the scoping review will be summarized. Keywords: Indocyanine Green, ICG, Sentinel Lymph Node, Breast Cancer, Fluorescence, Axillary Lymph Node Mapping, NIR