XZXing Zhang

Xing Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xing Zhang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Ji Yan

    National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics 1 , Mianyang 621900, China

    2 shared publications
  • Wei Jiang

    National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics 1 , Mianyang 621900, China

    2 shared publications
  • Yudong Pu

    National Key Laboratory of Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics

    2 shared publications
  • Baozhong Mu

    MOE Key Laboratory of Advanced Micro-Structured Materials, School of Physics Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China

    1 shared publication
  • Bo Yu

    China Acad Engn Phys, Laser Fus Res Ctr, Mianyang 621900, Sichuan, Peoples R China

    1 shared publication
  • Chen Yang

    Graduate School of China Academy of Engineering Physics 1 , Beijing 100193, China

    1 shared publication

Latest Publications

  • Open Access

    Quantitative Analysis of Acquisition Speed of High-Precision FLIM Technologies via Simulation and Modeling

    by Jinzheng Lu, Ling Miao, Jiaxing Wen, Qiang Li, Jingwei Chen, Qiang Yang, Xing Zhang, Jin Li, Yuchi Wu, Yue Yang, et al.

    In practical applications such as cancer diagnosis and industrial detection, there is a critical demand for fast fluorescence lifetime imaging (Fast-FLIM). The Fast-FLIM systems suitable for complex environments are typically achieved by enhancing the hardware performance of time-correlated single-photon counting (TCSPC), with an acquisition speed of about a few frames per second (fps). However, due to the limitation of single-photon acquisition, the imaging speed is still far from the demand of practical application. The synchroscan streak camera (SC) maps signals from the temporal dimension to the spatial dimension, effectively overcoming the long acquisition time caused by single-photon acquisition. This paper constructs a method to calculate the acquisition time for the TCSPC-FLIM and SC-FLIM systems, and it quantitatively compares the speed. The research demonstrates that the main factors limiting the acquisition speed of the FLIM systems are the photon emission rate, the photon counting rate, the required SNR, the dwell time, and the number of parallel channels. In high-quality and large-scale lifetime imaging, the acquisition speed of the SC-FLIM is at least 104 times faster than that of the TCSPC-FLIM. Therefore, the synchroscan streak camera has more significant potential to promote Fast-FLIM.


  • Open Access

    Hot spot localization in the field of view of the Kirkpatrick–Baez microscope

    by Yankang Wu, Pin Yang, Xing Zhang, Jianjun Dong, Jie Xu, Mingtao Li, Zhongjing Chen, Yingjie Li, Wei Jiang, Chuankui Sun, et al.

    The Kirkpatrick–Baez (KB) microscope is an effective instrument for x-ray imaging of hot spot. However, the non-uniform distribution of response efficiency in the field of view is a drawback of the KB microscope. A more accurate hot spot image requires the correction of the measured image by combining the hot spot position and the response efficiency distribution. Here, we describe a method to locate the position of the hot spot in the field of view during hot spot imaging with a KB microscope. The position of the hot spot in the field of view can be obtained by measuring the grazing incidence angle change during hot spot imaging. In the experiment of hot spot self-emission imaging with a four-channel KB microscope, the location of the hot spot with an accuracy of 15 μm was realized, and the intensity corrected hot spot image was obtained. This will solve the problem of the non-uniform distribution of the response efficiency of the KB microscope and enable quantitative measurement of hot spot radiation intensity.


  • The investigation of spherically convergent plasma fusion as a high-flux neutron source with a long-pulsed laser driving

    by Ji Yan, Guo Li Ren, Zhong Jing Chen, Xing Zhang, Chen Yang, Li Ling Li, Jian Hua Zheng, Hui Cao, Chuan Kui Sun, Wei Jiang, et al.

    The spherically convergent plasma fusion (SCPF) scheme is a robust approach to provide a high-brightness pulsed neutron source. The performance of the SCPF driven by the long-pulsed laser is investigated. The experiments, with the laser pulse duration in a range of 0.5 ns to 3 ns, were implemented on the ShenGuang-II Upgrade facility and a 100 kJ level laser facility. The intensity of the laser beam was about multiple 1014 W cm−2. The measured D–D reaction neutron yields were in a range of 7.3 × 108 to 1.01 × 1011, while the driven laser energies were in a range of 2.1 kJ to 100.5 kJ. The temporal self-emitted x-ray flux and image were measured. It showed that the plasma core could be maintained for a longer time in the long duration shots. The neutron reaction rate was measured on the 100 kJ level laser facility. The full width at half maximum reached about 1 ns in the shot with 2 ns duration laser. The scaling law of the measured yields with respect to the laser power and the pulse duration were presented. The neutron yield was able to be increased by increasing the power and extending the duration.