Yu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Liu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Xing Cheng
Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, China
4 shared publications Hongjun Liu
3 shared publicationsRongyue Liu
3 shared publicationsZijun Chen
3 shared publications- Ji Tae Kim
Department of Mechanical Engineering Korea Advanced Institute of Science and Technology (KAIST) Daejeon Republic of Korea
2 shared publications - Kaicheng Huang
Materials Science and Engineering Department, Southern University of Science and Technology, China
2 shared publications
Latest Publications
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
A High-Accuracy Single-Cell Impedance Measurement System for Electrical Impedance Spectroscopy With Movable Electrical Tweezers
Non-contact cell impedance measurement is a highly promising tool for cell analysis. However, conventional techniques typically rely on fixed electrodes, which may restrict their versatility and accuracy. This study introduces an innovative cell impedance measurement system utilizing movable electrical tweezers to achieve high-accuracy single-cell impedance measurements for electrical impedance spectroscopy (EIS). In this system, a microchip with integrated electrodes was mounted on a triaxial platform to function as the movable electrical tweezers. The cell impedance can be accurately measured by accurately positioning the cell directly beneath the electrical tweezers. Both simulation and experimental investigations were conducted to examine the effects of various environmental parameters, particularly the volume ratio and the relative position between the cells and electrical tweezers, on EIS measurement accuracy. The results demonstrate that these parameters play crucial roles in cell impedance measurement. Experiments were also performed to measure the EIS and density scatter opacity of polystyrene (PS) beads, SW480 cells, and yeast cells. The EIS results reveal distinct differences among these microparticles, while the opacity results clearly cluster impedance values. The proposed electrical tweezers system exhibits remarkable capability for high-accuracy single-cell impedance measurements, with significant impedance differences observed when cells are positioned at varying distances relative to the detecting electrode. This technique offers a novel and promising approach for high-accuracy cell impedance measurement, with potential applications in cell-based assays and phenotypic identification.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
A High-Accuracy Single-Cell Impedance Measurement System for Electrical Impedance Spectroscopy With Movable Electrical Tweezers
Non-contact cell impedance measurement is a highly promising tool for cell analysis. However, conventional techniques typically rely on fixed electrodes, which may restrict their versatility and accuracy. This study introduces an innovative cell impedance measurement system utilizing movable electrical tweezers to achieve high-accuracy single-cell impedance measurements for electrical impedance spectroscopy (EIS). In this system, a microchip with integrated electrodes was mounted on a triaxial platform to function as the movable electrical tweezers. The cell impedance can be accurately measured by accurately positioning the cell directly beneath the electrical tweezers. Both simulation and experimental investigations were conducted to examine the effects of various environmental parameters, particularly the volume ratio and the relative position between the cells and electrical tweezers, on EIS measurement accuracy. The results demonstrate that these parameters play crucial roles in cell impedance measurement. Experiments were also performed to measure the EIS and density scatter opacity of polystyrene (PS) beads, SW480 cells, and yeast cells. The EIS results reveal distinct differences among these microparticles, while the opacity results clearly cluster impedance values. The proposed electrical tweezers system exhibits remarkable capability for high-accuracy single-cell impedance measurements, with significant impedance differences observed when cells are positioned at varying distances relative to the detecting electrode. This technique offers a novel and promising approach for high-accuracy cell impedance measurement, with potential applications in cell-based assays and phenotypic identification.
- Open Access
- 6 February 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (6) , eadz7415
Three-dimensional printing of nanomaterials-based electronics with a metamaterial-inspired near-field electromagnetic structure
Three-dimensional (3D) printing can create freeform architectures and electronics with unprecedented versatility. However, the full potential of electronic 3D printing has so far been limited by the inability to selectively anneal the printed materials, especially on temperature-sensitive substrates. Here, we achieve highly selective and rapid volumetric heating of 3D-printed nanomaterials and polymers in situ by focusing microwaves using a metamaterial-inspired near-field electromagnetic structure (Meta-NFS). In contrast to previous work, the Meta-NFS achieves the spatial resolution and power density needed to 3D print freeform microstructures where the electronic and mechanical properties can be locally programmed even within optically opaque materials. By broadening the material palettes compatible with 3D printing, near-field microwave 3D printing with Meta-NFS enables classes of electronics that are otherwise challenging to create.
- 6 February 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (6) , eadz7415
Open AccessThree-dimensional printing of nanomaterials-based electronics with a metamaterial-inspired near-field electromagnetic structure
Three-dimensional (3D) printing can create freeform architectures and electronics with unprecedented versatility. However, the full potential of electronic 3D printing has so far been limited by the inability to selectively anneal the printed materials, especially on temperature-sensitive substrates. Here, we achieve highly selective and rapid volumetric heating of 3D-printed nanomaterials and polymers in situ by focusing microwaves using a metamaterial-inspired near-field electromagnetic structure (Meta-NFS). In contrast to previous work, the Meta-NFS achieves the spatial resolution and power density needed to 3D print freeform microstructures where the electronic and mechanical properties can be locally programmed even within optically opaque materials. By broadening the material palettes compatible with 3D printing, near-field microwave 3D printing with Meta-NFS enables classes of electronics that are otherwise challenging to create.
- Open Access
- 1 December 2025
- Published by KEAI Publishing in Biomedical Instrumentation
- Vol. 1 (2)
Ultrafast polymerase chain reaction on MEMS microheater
- 1 December 2025
- Published by KEAI Publishing in Biomedical Instrumentation
- Vol. 1 (2)
Open AccessUltrafast polymerase chain reaction on MEMS microheater
- 23 May 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (12) , 2807-2815
Semi-permeable membrane stabilized microfluidic plasma chip for continuous, tunable synthesis of sub-10 nm nanoparticles
A microplasma integrated microfluidic chip with a semi-permeable membrane stabilized the plasma/liquid interface, enabling an additional adjustment approach for uniform, precise, and tunable nanoparticle synthesis.
- 23 May 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (12) , 2807-2815
Semi-permeable membrane stabilized microfluidic plasma chip for continuous, tunable synthesis of sub-10 nm nanoparticles
A microplasma integrated microfluidic chip with a semi-permeable membrane stabilized the plasma/liquid interface, enabling an additional adjustment approach for uniform, precise, and tunable nanoparticle synthesis.
- Open Access
- 13 August 2024
- Published by Springer Nature in Research Square
Ultrafast Polymerase Chain Reaction on MEMS Microheater
Ultrafast polymerase chain reaction (PCR) is crucial for the rapid detection of pathogens, particularly in medical emergencies and public health scenarios. Conventional PCR systems, however, require extended processing times due to the inherent mass transfer rates of ~ 10 µL scale liquids. This study aims to achieve ultrafast nucleic acid amplification using a MEMS microheater to significantly reduce reaction volumes from a typical 10 µL PCR system to 3 nL, resulting in a total duration of 304 seconds for 38 thermal cycling. Temperature mapping and calibrations were conducted using infrared microscopy, and COMSOL simulations were employed to analyze thermal behavior and fluid dynamics within the droplets. The droplets were heated at a rate of 254°C/s and cooled at a rate of 122°C/s through natural thermal balance. The calibrated microheater exhibited high-temperature stability with a variation of ± 0.1°C, and efficient PCR amplification of HBV DNA and Coronavirus RNA samples were demonstrated, with Ct values significantly lower than those obtained using commercial equipment. As well, successful reverse transcription and PCR amplification of RNA samples were achieved. However, due to the limitations of the commercial reagents under such a short cycling duration, the amplification efficiency was undermined, being calculated at 88%. This technology offers a viable solution for rapid pathogen detection and holds potential for widespread applications in medical diagnostics and public health, particularly during pandemic outbreaks.
- 13 August 2024
- Published by Springer Nature in Research Square
Open AccessUltrafast Polymerase Chain Reaction on MEMS Microheater
Ultrafast polymerase chain reaction (PCR) is crucial for the rapid detection of pathogens, particularly in medical emergencies and public health scenarios. Conventional PCR systems, however, require extended processing times due to the inherent mass transfer rates of ~ 10 µL scale liquids. This study aims to achieve ultrafast nucleic acid amplification using a MEMS microheater to significantly reduce reaction volumes from a typical 10 µL PCR system to 3 nL, resulting in a total duration of 304 seconds for 38 thermal cycling. Temperature mapping and calibrations were conducted using infrared microscopy, and COMSOL simulations were employed to analyze thermal behavior and fluid dynamics within the droplets. The droplets were heated at a rate of 254°C/s and cooled at a rate of 122°C/s through natural thermal balance. The calibrated microheater exhibited high-temperature stability with a variation of ± 0.1°C, and efficient PCR amplification of HBV DNA and Coronavirus RNA samples were demonstrated, with Ct values significantly lower than those obtained using commercial equipment. As well, successful reverse transcription and PCR amplification of RNA samples were achieved. However, due to the limitations of the commercial reagents under such a short cycling duration, the amplification efficiency was undermined, being calculated at 88%. This technology offers a viable solution for rapid pathogen detection and holds potential for widespread applications in medical diagnostics and public health, particularly during pandemic outbreaks.