Ignazio Kurti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ignazio Kurti has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anna Di Marzio
Department of Medicine, Surgery, and Pharmacy, University of Sassari, 07100 Sassari, Italy
2 shared publications - Aurea Immacolata Lumbau
Department of Medicine, Surgery, and Pharmacy, University of Sassari, 07100 Sassari, Italy
2 shared publications - Francesco Mollica
Department of Engineering, University of Ferrara, 44121 Ferrara, Italy
2 shared publications - Gabriele Cervino
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Messina, Italy
2 shared publications - Marco Tallarico
Department of Medicine, Surgery, and Pharmacy, University of Sassari, 07100 Sassari, Italy
2 shared publications - Mario Cesare Pozzan
Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
2 shared publications
Latest Publications
- Open Access
- 27 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8751
Mechanical Behaviors of a New Polymer-Based Restorative Material for Immediate Loading: An In Vitro Comparative Study
The aim of the present in vitro comparative study is to validate a novel composite polymer, named “ONLY”, developed to overcome the mechanical drawbacks of conventional, metal-reinforced poly(methyl methacrylate) (PMMA) interim restoration. Ten interim restorations were designed and fabricated (five in the composite “ONLY” group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were break point (load, N) and displacement (mm) through a static compression test, and material behavior through a dynamic cyclic test method (fatigue test). A total of 20 samples were tested (10 for static and 10 for dynamic). In each group, five samples (test and control) were used. All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for any test. In the test group, the break point was 1953.19 ± 543.73 N, while it was 2031.10 ± 716.68 N in the control group (p = 0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group (p = 0.763). Using the dynamic cyclic test method, in the control group the mean load was 2504.60 ± 972.15 N, while in the test group the mean load was 3382.00 ± 578.50 N. The difference between groups was 877.40 ± 579.30 N (p value = 0.121). Within the limitations of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical research is needed to confirm these preliminary results.
- 27 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8751
Open AccessMechanical Behaviors of a New Polymer-Based Restorative Material for Immediate Loading: An In Vitro Comparative Study
The aim of the present in vitro comparative study is to validate a novel composite polymer, named “ONLY”, developed to overcome the mechanical drawbacks of conventional, metal-reinforced poly(methyl methacrylate) (PMMA) interim restoration. Ten interim restorations were designed and fabricated (five in the composite “ONLY” group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were break point (load, N) and displacement (mm) through a static compression test, and material behavior through a dynamic cyclic test method (fatigue test). A total of 20 samples were tested (10 for static and 10 for dynamic). In each group, five samples (test and control) were used. All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for any test. In the test group, the break point was 1953.19 ± 543.73 N, while it was 2031.10 ± 716.68 N in the control group (p = 0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group (p = 0.763). Using the dynamic cyclic test method, in the control group the mean load was 2504.60 ± 972.15 N, while in the test group the mean load was 3382.00 ± 578.50 N. The difference between groups was 877.40 ± 579.30 N (p value = 0.121). Within the limitations of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical research is needed to confirm these preliminary results.
- Open Access
- 15 August 2024
- Published by MDPI AG in Preprints.org
Mechanical Behaviors of a New Polymer-Based Restorative Material for Immediate Loading: An In-Vitro, Comparative, Research
Metal-reinforced polymethyl-methacrylate (PMMA) is considered the gold standard material for immediate loading on dental implants. However, mechanical problems under loading cycles can occur, such as fractures. To overcome these drawbacks, a novel polymer-based material has been proposed. The aim of the present in vitro comparative research is to validate a novel composite polymer developed to replace metal-reinforced PMMA interim restoration due to its advantages of good mechanical proprieties, easier manufacturing, and handling. Ten interim restorations were CAD/CAM designed and fabricated (five in the composite "ONLY" group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were breakpoint (load, N) and displacement (mm) thought a static, compression test and material behavior under dynamic cyclic test method (fatigue test). A total of twenty samples were tested. Ten samples were used for each test (10 for static and 10 for dynamic), five samples were used in each group (test and control). All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for all, breakpoint, displacement and fatigue tests. Breakpoint in the test group was 1953.19 ± 543.73 N, while, it was 2031.10 ± 716.68 N in the control group, with no statistically significant difference (P=0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group, again, with no statistically significant difference (P=0.763). Under dynamic cyclic test method, in the control group the mean load was 2504.6 ± 972.15 N, while, in the test group the mean load was 3382 ± 578.5 N. The difference between group was 877.4 ± 579.3 N (p value=0.121). With the limitation of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical researches are needed to confirm this preliminary results.
- 15 August 2024
- Published by MDPI AG in Preprints.org
Open AccessMechanical Behaviors of a New Polymer-Based Restorative Material for Immediate Loading: An In-Vitro, Comparative, Research
Metal-reinforced polymethyl-methacrylate (PMMA) is considered the gold standard material for immediate loading on dental implants. However, mechanical problems under loading cycles can occur, such as fractures. To overcome these drawbacks, a novel polymer-based material has been proposed. The aim of the present in vitro comparative research is to validate a novel composite polymer developed to replace metal-reinforced PMMA interim restoration due to its advantages of good mechanical proprieties, easier manufacturing, and handling. Ten interim restorations were CAD/CAM designed and fabricated (five in the composite "ONLY" group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were breakpoint (load, N) and displacement (mm) thought a static, compression test and material behavior under dynamic cyclic test method (fatigue test). A total of twenty samples were tested. Ten samples were used for each test (10 for static and 10 for dynamic), five samples were used in each group (test and control). All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for all, breakpoint, displacement and fatigue tests. Breakpoint in the test group was 1953.19 ± 543.73 N, while, it was 2031.10 ± 716.68 N in the control group, with no statistically significant difference (P=0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group, again, with no statistically significant difference (P=0.763). Under dynamic cyclic test method, in the control group the mean load was 2504.6 ± 972.15 N, while, in the test group the mean load was 3382 ± 578.5 N. The difference between group was 877.4 ± 579.3 N (p value=0.121). With the limitation of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical researches are needed to confirm this preliminary results.