Jiawei Bao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiawei Bao has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Rui An
6 shared publications- Yangwei Wang
Marine Science and Technology Domain, Beijing Institute of Technology, Zhuhai, Zhuhai 519088, China
6 shared publications Changle Zhang
4 shared publicationsFangzhou Zhang
3 shared publicationsYangwei Wang
3 shared publicationsBingyue Jiang
2 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by Elsevier in SSRN Electronic Journal
Influence of Interfacial Reaction on Mechanical Properties and Energy Absorption Performance of HGM/Al Composites
In this study, hollow glass microsphere/aluminum (HGM/Al) composites were fabricated via vacuum pressure infiltration method using Al-Si alloys with varying Si contents as the matrix. were annealed at 400 ℃ and solutiontreated at 550 ℃ and aged at 170 ℃, respectively. The influence and mechanisms of interfacial reaction on the mechanical properties and energy absorption performance of composites were systematically investigated. The results demonstrated that during solution treatment, HGM was prone to interface react with the Al matrix, forming loose reaction products mainly composed of γ-Al2O3, which degraded the load-bearing capacity of the HGM. In HGM/ZL101, up to 70% microspheres exhibited completely interfacial reaction, whereas in HGM/ZL102, the proportion was 8.2%, indicating that the extent of interfacial reaction decreased as the silicon content increased from 7 wt.% (ZL101) to 12 wt.% (ZL102). With increasing interfacial reaction extent, the damage mode after stress peak transformed from a sudden localized instability governed by a single shear band traversing the specimen to a progressive localized instability characterized by the sequential initiation and propagation of multiple small-scale shear bands. Compared with the annealed condition, the solution-treated and aged HGM/ZL101 exhibited reductions of 21.5% in compression plateau stress and 18.4% in specific energy absorption. In contrast, HGM/ZL102, benefiting from the higher Si content of the matrix which effectively inhibited interfacial reaction, achieving enhanced mechanical properties through precipitation strengthening, with plateau stress and specific energy absorption increasing by 9.4% and 10.5% respectively over the annealed condition, reaching 151.87 MPa and 63.89 kJ/kg.
- 5 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessInfluence of Interfacial Reaction on Mechanical Properties and Energy Absorption Performance of HGM/Al Composites
In this study, hollow glass microsphere/aluminum (HGM/Al) composites were fabricated via vacuum pressure infiltration method using Al-Si alloys with varying Si contents as the matrix. were annealed at 400 ℃ and solutiontreated at 550 ℃ and aged at 170 ℃, respectively. The influence and mechanisms of interfacial reaction on the mechanical properties and energy absorption performance of composites were systematically investigated. The results demonstrated that during solution treatment, HGM was prone to interface react with the Al matrix, forming loose reaction products mainly composed of γ-Al2O3, which degraded the load-bearing capacity of the HGM. In HGM/ZL101, up to 70% microspheres exhibited completely interfacial reaction, whereas in HGM/ZL102, the proportion was 8.2%, indicating that the extent of interfacial reaction decreased as the silicon content increased from 7 wt.% (ZL101) to 12 wt.% (ZL102). With increasing interfacial reaction extent, the damage mode after stress peak transformed from a sudden localized instability governed by a single shear band traversing the specimen to a progressive localized instability characterized by the sequential initiation and propagation of multiple small-scale shear bands. Compared with the annealed condition, the solution-treated and aged HGM/ZL101 exhibited reductions of 21.5% in compression plateau stress and 18.4% in specific energy absorption. In contrast, HGM/ZL102, benefiting from the higher Si content of the matrix which effectively inhibited interfacial reaction, achieving enhanced mechanical properties through precipitation strengthening, with plateau stress and specific energy absorption increasing by 9.4% and 10.5% respectively over the annealed condition, reaching 151.87 MPa and 63.89 kJ/kg.
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Influence of Interfacial Reaction on Mechanical Properties and Energy Absorption Performance of HGM/Al Composites
In this study, hollow glass microsphere/aluminum (HGM/Al) composites were fabricated via vacuum pressure infiltration method using Al-Si alloys with varying Si contents as the matrix. were annealed at 400 ℃ and solutiontreated at 550 ℃ and aged at 170 ℃, respectively. The influence and mechanisms of interfacial reaction on the mechanical properties and energy absorption performance of composites were systematically investigated. The results demonstrated that during solution treatment, HGM was prone to interface react with the Al matrix, forming loose reaction products mainly composed of γ-Al2O3, which degraded the load-bearing capacity of the HGM. In HGM/ZL101, up to 70% microspheres exhibited completely interfacial reaction, whereas in HGM/ZL102, the proportion was 8.2%, indicating that the extent of interfacial reaction decreased as the silicon content increased from 7 wt.% (ZL101) to 12 wt.% (ZL102). With increasing interfacial reaction extent, the damage mode after stress peak transformed from a sudden localized instability governed by a single shear band traversing the specimen to a progressive localized instability characterized by the sequential initiation and propagation of multiple small-scale shear bands. Compared with the annealed condition, the solution-treated and aged HGM/ZL101 exhibited reductions of 21.5% in compression plateau stress and 18.4% in specific energy absorption. In contrast, HGM/ZL102, benefiting from the higher Si content of the matrix which effectively inhibited interfacial reaction, achieving enhanced mechanical properties through precipitation strengthening, with plateau stress and specific energy absorption increasing by 9.4% and 10.5% respectively over the annealed condition, reaching 151.87 MPa and 63.89 kJ/kg.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessInfluence of Interfacial Reaction on Mechanical Properties and Energy Absorption Performance of HGM/Al Composites
In this study, hollow glass microsphere/aluminum (HGM/Al) composites were fabricated via vacuum pressure infiltration method using Al-Si alloys with varying Si contents as the matrix. were annealed at 400 ℃ and solutiontreated at 550 ℃ and aged at 170 ℃, respectively. The influence and mechanisms of interfacial reaction on the mechanical properties and energy absorption performance of composites were systematically investigated. The results demonstrated that during solution treatment, HGM was prone to interface react with the Al matrix, forming loose reaction products mainly composed of γ-Al2O3, which degraded the load-bearing capacity of the HGM. In HGM/ZL101, up to 70% microspheres exhibited completely interfacial reaction, whereas in HGM/ZL102, the proportion was 8.2%, indicating that the extent of interfacial reaction decreased as the silicon content increased from 7 wt.% (ZL101) to 12 wt.% (ZL102). With increasing interfacial reaction extent, the damage mode after stress peak transformed from a sudden localized instability governed by a single shear band traversing the specimen to a progressive localized instability characterized by the sequential initiation and propagation of multiple small-scale shear bands. Compared with the annealed condition, the solution-treated and aged HGM/ZL101 exhibited reductions of 21.5% in compression plateau stress and 18.4% in specific energy absorption. In contrast, HGM/ZL102, benefiting from the higher Si content of the matrix which effectively inhibited interfacial reaction, achieving enhanced mechanical properties through precipitation strengthening, with plateau stress and specific energy absorption increasing by 9.4% and 10.5% respectively over the annealed condition, reaching 151.87 MPa and 63.89 kJ/kg.
- 1 March 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (3) , 035017
Research on the preparation, mechanical properties, and applications of damage-sensing composite materials
Structural health monitoring is a well-established field for carbon fiber composites, a class of materials prevalent in ballistic protection systems. However, real-time damage monitoring within bulletproof structures remains largely unexplored. This study used gallium-indium liquid metal, which possessed fluidity and high conductivity, to fabricate flexible sensing material and explore its potential application on bulletproof plates. The relationship between microstructural deformation of the sensors and their electrical response under low-velocity impact loading conditions still remains unclear. The gallium-indium liquid metal flexible sensors were fabricated by the flexible electronic printing equipment. The mechanical and electrical responses of the sensors under quasi-static and dynamic loading conditions were investigated, and the microstructural evolution and failure mechanisms of the liquid-metal traces under different deformation and failure modes were analyzed. This work designed damage sensing grids and combined them with ultra-high molecular weight polyethylene plates to validate the damage localization functionality. The results showed that the liquid metal flexible sensor exhibited a wide strain range (up to 60%), excellent repeatability (the resistance amplitude remained stable after 500 cycles of repeated loading), and a significant piezoresistive effect under bending and low-velocity impact. Additionally, the failure modes of the sensor under tensile, bending, and impact conditions were also investigated. These failures obstructed current flow, leading to increased resistance or even circuit breakage. The fabricated damage-sensing composite device demonstrated damage localization within a spatial range of (±2 mm) × (±2 mm), with successful trials/total trials = 4/5.
- 1 March 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (3) , 035017
Research on the preparation, mechanical properties, and applications of damage-sensing composite materials
Structural health monitoring is a well-established field for carbon fiber composites, a class of materials prevalent in ballistic protection systems. However, real-time damage monitoring within bulletproof structures remains largely unexplored. This study used gallium-indium liquid metal, which possessed fluidity and high conductivity, to fabricate flexible sensing material and explore its potential application on bulletproof plates. The relationship between microstructural deformation of the sensors and their electrical response under low-velocity impact loading conditions still remains unclear. The gallium-indium liquid metal flexible sensors were fabricated by the flexible electronic printing equipment. The mechanical and electrical responses of the sensors under quasi-static and dynamic loading conditions were investigated, and the microstructural evolution and failure mechanisms of the liquid-metal traces under different deformation and failure modes were analyzed. This work designed damage sensing grids and combined them with ultra-high molecular weight polyethylene plates to validate the damage localization functionality. The results showed that the liquid metal flexible sensor exhibited a wide strain range (up to 60%), excellent repeatability (the resistance amplitude remained stable after 500 cycles of repeated loading), and a significant piezoresistive effect under bending and low-velocity impact. Additionally, the failure modes of the sensor under tensile, bending, and impact conditions were also investigated. These failures obstructed current flow, leading to increased resistance or even circuit breakage. The fabricated damage-sensing composite device demonstrated damage localization within a spatial range of (±2 mm) × (±2 mm), with successful trials/total trials = 4/5.
- 4 February 2026
- Published by Elsevier in Applied Materials Today
- Vol. 48
Effect of preform on the compressive behavior and energy absorption performance of hollow glass microsphere/aluminum composites
- 4 February 2026
- Published by Elsevier in Applied Materials Today
- Vol. 48
Effect of preform on the compressive behavior and energy absorption performance of hollow glass microsphere/aluminum composites
- 25 July 2025
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 207
Study on anti-explosion performance and mechanism of lattice sandwich panels of Ti-6Al-4V alloy
- 25 July 2025
- Published by Elsevier in International Journal of Impact Engineering
- Vol. 207
Study on anti-explosion performance and mechanism of lattice sandwich panels of Ti-6Al-4V alloy
- Open Access
- 13 August 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 32, 2370-2385
Predicting ballistic resistance based on the mechanical properties of armored ceramics
- 13 August 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 32, 2370-2385
Open AccessPredicting ballistic resistance based on the mechanical properties of armored ceramics
- Open Access
Numerical Simulation of Squeeze-Casting SiC3D/Al Ceramic Matrix Composites
In this study, the filling and solidification processes of squeeze-casting SiC3D/Al composites were analyzed by the ProCAST simulation software (ver. 2018.0). A practical squeeze-casting experiment was conducted to verify the accuracy of the simulation results. A series of orthogonal experiments were conducted on the initial preheating temperature of various components to identify the optimal parameters in order to achieve better porosity and stress concentration values. According to the results and analyses, the preheating temperature of the mold was the most important determining factor. Under a pouring temperature of 700 °C, mold preheating temperature of 200 °C, and SiC skeleton preheating temperature of 600 °C, the maximum principal stress at the bottom of the products was decreased by about 41.9%, and the shrinkage volume inside the composite was decreased about by about 61.6%. Thus, by adjusting the initial preheating temperature of various components, the squeeze-casting SiC3D/Al composites could achieve better performance and fewer internal defects.
Open AccessNumerical Simulation of Squeeze-Casting SiC3D/Al Ceramic Matrix Composites
In this study, the filling and solidification processes of squeeze-casting SiC3D/Al composites were analyzed by the ProCAST simulation software (ver. 2018.0). A practical squeeze-casting experiment was conducted to verify the accuracy of the simulation results. A series of orthogonal experiments were conducted on the initial preheating temperature of various components to identify the optimal parameters in order to achieve better porosity and stress concentration values. According to the results and analyses, the preheating temperature of the mold was the most important determining factor. Under a pouring temperature of 700 °C, mold preheating temperature of 200 °C, and SiC skeleton preheating temperature of 600 °C, the maximum principal stress at the bottom of the products was decreased by about 41.9%, and the shrinkage volume inside the composite was decreased about by about 61.6%. Thus, by adjusting the initial preheating temperature of various components, the squeeze-casting SiC3D/Al composites could achieve better performance and fewer internal defects.
- Open Access
The Effect of Interlayer Materials on Ceramic Damage in SiC/Al Composite Structure
The effect of interlayer materials on the damage of ceramics in the SiC/Al composite structure was analyzed through experiments and simulation. Using 0.25 mm thermoplastic polyurethane (TPU) as a reference, a 0.5 mm aramid fabric (AFRP) or a 0.5 mm carbon fiber reinforced epoxy matrix composite (CFRP) was added to the interlayer, respectively. Through the impact tests, it was discovered that the ceramic damaged area in the TPU composite structure was severe. With the addition of AFRP, the damaged area of the ceramic layer was reduced by 73% under the same impact conditions. The addition of CFRP also reduced the damage of ceramics. The evolution process of the tensile stress on the ceramic rear surface was presented by simulation. The tensile evolution process analysis can explain the experimental phenomenon well and can be used to predict the damage of the ceramics.
Open AccessThe Effect of Interlayer Materials on Ceramic Damage in SiC/Al Composite Structure
The effect of interlayer materials on the damage of ceramics in the SiC/Al composite structure was analyzed through experiments and simulation. Using 0.25 mm thermoplastic polyurethane (TPU) as a reference, a 0.5 mm aramid fabric (AFRP) or a 0.5 mm carbon fiber reinforced epoxy matrix composite (CFRP) was added to the interlayer, respectively. Through the impact tests, it was discovered that the ceramic damaged area in the TPU composite structure was severe. With the addition of AFRP, the damaged area of the ceramic layer was reduced by 73% under the same impact conditions. The addition of CFRP also reduced the damage of ceramics. The evolution process of the tensile stress on the ceramic rear surface was presented by simulation. The tensile evolution process analysis can explain the experimental phenomenon well and can be used to predict the damage of the ceramics.