Yong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yong Liu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Cao Zhan
Bradley Department of Electrical and Computer Engineering (ECE), Center for Power Electronics Systems (CPES), Virginia Tech, Blacksburg, VA, USA
1 shared publication - Fuqiang Ren
State key laboratory of electrical insulation and power equipment, Xi'an Jiaotong University, 12480 Xi'an, Shaanxi China 710049
1 shared publication - Gang Shi
Shanghai Jiao Tong University
1 shared publication - Jiacheng Wang
School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC V3T 5X3, Canada
1 shared publication - Jiajie Zang
Shanghai University of Engineering Science
1 shared publication - Jianqiao Zhou
Shanghai Jiao Tong University
1 shared publication
Latest Publications
- 28 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 4278-4290
A Novel Multiport Transformer-Less Unified Power Flow Controller
High cost and large volume are always associated with the conventional unified power flow controller (UPFC) formed by two back-to-back connected voltage source converters and two transformers. Both additional series-connected converters and their adjacent transformers are necessitated when controlling the power flow among multiple transmission lines. Such implementation will further increase the cost and volume of the equipment owing to the port expansion. In this regard, this paper proposes a multiport transformer-less UPFC (MTUPFC) with easy terminal expandability. The decoupled active and reactive power flow are also controlled independently. This device presents several advantages, including low cost, light weight, fast dynamic response characteristics, and easy port expansion. The MTUPFC therefore has significant advantages in power grids with complex configuration and large-scale renewable energy integration. The operation principle and control strategies of the proposed MTUPFC are elaborated. The feasibility and effectiveness of the MTUPFC are verified by a 60-MVA simulation model and a 2.5-kVA scaled-down experimental platform, respectively.
- 28 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 4278-4290
A Novel Multiport Transformer-Less Unified Power Flow Controller
High cost and large volume are always associated with the conventional unified power flow controller (UPFC) formed by two back-to-back connected voltage source converters and two transformers. Both additional series-connected converters and their adjacent transformers are necessitated when controlling the power flow among multiple transmission lines. Such implementation will further increase the cost and volume of the equipment owing to the port expansion. In this regard, this paper proposes a multiport transformer-less UPFC (MTUPFC) with easy terminal expandability. The decoupled active and reactive power flow are also controlled independently. This device presents several advantages, including low cost, light weight, fast dynamic response characteristics, and easy port expansion. The MTUPFC therefore has significant advantages in power grids with complex configuration and large-scale renewable energy integration. The operation principle and control strategies of the proposed MTUPFC are elaborated. The feasibility and effectiveness of the MTUPFC are verified by a 60-MVA simulation model and a 2.5-kVA scaled-down experimental platform, respectively.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1-6
Winding Mechanical Fault Diagnosis Technique of Power Transformer Based on Time-Frequency Vibration Analysis
Huge electromagnetic force during sudden short circuit can cause severe winding mechanical fault. Transformer tank vibration characteristics are closely related to winding mechanical condition. Transient vibration response on transformer tank under short circuit impact can be utilized to monitor winding condition and diagnose winding fault. Short circuit impact experiment according to IEC standard is performed on a 110kV transformer. 33 times impacts were performed at A-phase and tank vibration signal is recorded every time during the impact. Since transformer transient vibration signal is non-linear and non-stationary, this paper utilizes Hilbert-Huang Transform (HHT) methodology to analyze transformer vibration signal in time-frequency domain. 200Hz-1000Hz component in Hilbert spectrum is deeply studied. Image processing method is used to quantity the occurrence number of frequency above 200Hz in Hilbert spectrum. The result shows 800Hz-1000Hz component increases largely during 23 rd impact compared with the previous impact result. Thus, 800Hz-1000Hz component in Hilbert spectrum can be regarded as an indicator to diagnose winding fault. What's more, Short Circuit Impedance (SCI) experiment shows that SCI variation rate of A-phase changes 1 % after 24th impact and increases to -21.85% after 33rd impact. Suspended core experiment after the short circuit impact experiment reveals that severe winding mechanical fault occurs in both high voltage winding and medium voltage winding. Both of the results validate the correctness of Hilbert spectrum analysis of transient vibration response. Therefore, time-frequency vibration analysis can be used to monitor winding condition and diagnose winding fault.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1-6
Winding Mechanical Fault Diagnosis Technique of Power Transformer Based on Time-Frequency Vibration Analysis
Huge electromagnetic force during sudden short circuit can cause severe winding mechanical fault. Transformer tank vibration characteristics are closely related to winding mechanical condition. Transient vibration response on transformer tank under short circuit impact can be utilized to monitor winding condition and diagnose winding fault. Short circuit impact experiment according to IEC standard is performed on a 110kV transformer. 33 times impacts were performed at A-phase and tank vibration signal is recorded every time during the impact. Since transformer transient vibration signal is non-linear and non-stationary, this paper utilizes Hilbert-Huang Transform (HHT) methodology to analyze transformer vibration signal in time-frequency domain. 200Hz-1000Hz component in Hilbert spectrum is deeply studied. Image processing method is used to quantity the occurrence number of frequency above 200Hz in Hilbert spectrum. The result shows 800Hz-1000Hz component increases largely during 23 rd impact compared with the previous impact result. Thus, 800Hz-1000Hz component in Hilbert spectrum can be regarded as an indicator to diagnose winding fault. What's more, Short Circuit Impedance (SCI) experiment shows that SCI variation rate of A-phase changes 1 % after 24th impact and increases to -21.85% after 33rd impact. Suspended core experiment after the short circuit impact experiment reveals that severe winding mechanical fault occurs in both high voltage winding and medium voltage winding. Both of the results validate the correctness of Hilbert spectrum analysis of transient vibration response. Therefore, time-frequency vibration analysis can be used to monitor winding condition and diagnose winding fault.