Xiaohong Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaohong Sun has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Zhipeng Cheng
2 State Key Laboratory of Bridge Safety and Resilience, Beijing University of Technology, Beijing, China
2 shared publications - Guipeng Chen
College of Engineering, Ocean University of China, Qingdao 266100, China
1 shared publication - Qi Yang
College of Engineering, Ocean University of China, Qingdao 266100, China
1 shared publication - Ruisheng Ma
College of Architecture & Civil Engineering, Beijing University of Technology, Beijing 100124, China
1 shared publication - Shenglin Li
CCCC Shanghai Harbour Engineering Design and Research Institute Co., Ltd., Shanghai 200032, China
1 shared publication - Shutong Yang
Department of Civil Engineering, College of Engineering, Ocean University of China, Qingdao, China
1 shared publication
Latest Publications
- Open Access
- 30 June 2025
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 27 (5) , 807-819
Dynamic performance analysis of 1000 MW double reheat steam turbine foundation
In recent years, power equipment has been developing towards low-carbon, high-efficiency, and green environmental protection. The double reheat unit has been increasingly employed in power plants due to its advantages of low energy consumption and less pollution. As a core component of power plants, the dynamic performance analysis of the steam turbine foundation is essential for ensuring the overall safety of double reheat unit. For this reason, the dynamic performance of a steam turbine foundation is investigated based on the engineering background of frame-type reinforced concrete foundations of 1000 MW double reheat steam turbine set in a power plant. The solid finite element model of the steam turbine foundation is first established by using ANSYS software, along with a detailed description of foundation information and modelling methodology. Subsequently, the dynamic characteristic and response analyses of the steam turbine foundation are performed to evaluate its dynamic performance, respectively. The results indicate that the 1000 MW steam turbine foundation demonstrates satisfactory dynamic performance. Within the operating speed range, the transverse, longitudinal, and vertical vibration displacements of the foundation bearings and columns remain below 20 μm, while the vibration velocity does not exceed 3.8 mm/s, both of which comply with relevant specifications. Moreover, enhancing the stiffness of the fifth and sixth beams, along with increasing the cross-sectional area of columns C3 and C4 on the steam turbine foundation, should be considered to mitigate its vibration responses and thus improve its dynamic performance. The research findings can serve as a reference for the type selection and optimization design of 1000 MW double reheat steam turbine foundations.
- 30 June 2025
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 27 (5) , 807-819
Open AccessDynamic performance analysis of 1000 MW double reheat steam turbine foundation
In recent years, power equipment has been developing towards low-carbon, high-efficiency, and green environmental protection. The double reheat unit has been increasingly employed in power plants due to its advantages of low energy consumption and less pollution. As a core component of power plants, the dynamic performance analysis of the steam turbine foundation is essential for ensuring the overall safety of double reheat unit. For this reason, the dynamic performance of a steam turbine foundation is investigated based on the engineering background of frame-type reinforced concrete foundations of 1000 MW double reheat steam turbine set in a power plant. The solid finite element model of the steam turbine foundation is first established by using ANSYS software, along with a detailed description of foundation information and modelling methodology. Subsequently, the dynamic characteristic and response analyses of the steam turbine foundation are performed to evaluate its dynamic performance, respectively. The results indicate that the 1000 MW steam turbine foundation demonstrates satisfactory dynamic performance. Within the operating speed range, the transverse, longitudinal, and vertical vibration displacements of the foundation bearings and columns remain below 20 μm, while the vibration velocity does not exceed 3.8 mm/s, both of which comply with relevant specifications. Moreover, enhancing the stiffness of the fifth and sixth beams, along with increasing the cross-sectional area of columns C3 and C4 on the steam turbine foundation, should be considered to mitigate its vibration responses and thus improve its dynamic performance. The research findings can serve as a reference for the type selection and optimization design of 1000 MW double reheat steam turbine foundations.
- Open Access
A Comparative Study of Inertial Mass Dampers and Negative Stiffness Dampers for the Multi-Mode Vibration Control of Stay Cables
Previous studies have demonstrated that two representative passive control devices, including inertial mass dampers (IMDs) and negative stiffness dampers (NSDs), exhibit superior control performance in single-mode vibration control of stay cables. However, observations in recent years have increasingly reported rain–wind-induced multi-mode vibrations of stay cables on actual bridges. Therefore, it is of considerable significance to investigate the control effectiveness of the two representative passive dampers in mitigating multi-mode cable vibrations. For this reason, this study presents a comparative study of the IMD and NSD for the multi-mode vibration control of stay cables. The mechanical models of typical IMDs and NSDs are first introduced, followed by the numerical modeling of the two cable-damper systems using the finite difference method. Subsequently, the effectiveness of three multi-mode optimization strategies is comprehensively assessed, and the most effective strategy is selected for the optimal design of the IMD and NSD. Finally, the effectiveness of the control of the IMD and NSD in suppressing harmonic, white noise and wind-induced multi-mode vibrations of a 493.72 (m) long ultra-long cable is systematically evaluated. The numerical results indicate that the NSD significantly improves the cable damping ratios for multiple vibration modes as its negative stiffness coefficient increases, while IMD performs well only within a small inertia coefficient. Moreover, the NSD outperforms the IMD in suppressing multi-mode cable vibrations induced by harmonic, white noise and wind excitations.
Open AccessA Comparative Study of Inertial Mass Dampers and Negative Stiffness Dampers for the Multi-Mode Vibration Control of Stay Cables
Previous studies have demonstrated that two representative passive control devices, including inertial mass dampers (IMDs) and negative stiffness dampers (NSDs), exhibit superior control performance in single-mode vibration control of stay cables. However, observations in recent years have increasingly reported rain–wind-induced multi-mode vibrations of stay cables on actual bridges. Therefore, it is of considerable significance to investigate the control effectiveness of the two representative passive dampers in mitigating multi-mode cable vibrations. For this reason, this study presents a comparative study of the IMD and NSD for the multi-mode vibration control of stay cables. The mechanical models of typical IMDs and NSDs are first introduced, followed by the numerical modeling of the two cable-damper systems using the finite difference method. Subsequently, the effectiveness of three multi-mode optimization strategies is comprehensively assessed, and the most effective strategy is selected for the optimal design of the IMD and NSD. Finally, the effectiveness of the control of the IMD and NSD in suppressing harmonic, white noise and wind-induced multi-mode vibrations of a 493.72 (m) long ultra-long cable is systematically evaluated. The numerical results indicate that the NSD significantly improves the cable damping ratios for multiple vibration modes as its negative stiffness coefficient increases, while IMD performs well only within a small inertia coefficient. Moreover, the NSD outperforms the IMD in suppressing multi-mode cable vibrations induced by harmonic, white noise and wind excitations.
- Open Access
Static Performance of Pre-Fabricated and Cast-in-Place Joints Formed by Inserting Steel Secondary Beam into Concrete Girder
Joints formed by inserting steel secondary beam (SSB) into concrete girders have been increasingly used in engineering practice (e.g., electric power). To demonstrate the static performance of these joints, two key variables including the construction method (prefabricated, cast-in-place) and the insertion form of SSB (unilateral, bilateral) were considered. The test results indicated that the failure mode of each joint was concrete punching by the inserted SSB. Compared with the joint specimens with unilateral insertion of SSB, the failure mode of the joint with bilateral insertion was changed from multiple to single cracking, exhibiting more obvious brittleness. When high-performance cement-based grouting materials were incorporated into the joint, the assembly and ductility of the joint were effectively improved. Compared with the cast-in-place counterparts, the displacement ductility coefficients of joints with prefabricated unilaterally and bilaterally inserted beams were enhanced by 22.9% and 41.3%, respectively. Moreover, a theoretical model was developed to evaluate the punching shear resistance of such joints with favorable accuracy.
Open AccessStatic Performance of Pre-Fabricated and Cast-in-Place Joints Formed by Inserting Steel Secondary Beam into Concrete Girder
Joints formed by inserting steel secondary beam (SSB) into concrete girders have been increasingly used in engineering practice (e.g., electric power). To demonstrate the static performance of these joints, two key variables including the construction method (prefabricated, cast-in-place) and the insertion form of SSB (unilateral, bilateral) were considered. The test results indicated that the failure mode of each joint was concrete punching by the inserted SSB. Compared with the joint specimens with unilateral insertion of SSB, the failure mode of the joint with bilateral insertion was changed from multiple to single cracking, exhibiting more obvious brittleness. When high-performance cement-based grouting materials were incorporated into the joint, the assembly and ductility of the joint were effectively improved. Compared with the cast-in-place counterparts, the displacement ductility coefficients of joints with prefabricated unilaterally and bilaterally inserted beams were enhanced by 22.9% and 41.3%, respectively. Moreover, a theoretical model was developed to evaluate the punching shear resistance of such joints with favorable accuracy.