Joyce Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joyce Kang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- David Steven Friedman
Department of Ophthalmology, Massachusetts Eye and Ear, Boston, Massachusetts
2 shared publications Yan Zhao
Department of Ophthalmology (J.K., U.G., K.S., Y.Z., Y.L., D.S.F., J.L.W., A.V.S., N.Z.), Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA
2 shared publications- Ana Roldan-Vasquez
Department of Ophthalmology, Penn State College of Medicine, Hershey, Pennsylvania
1 shared publication Ayellet V. Segrè
Department of Ophthalmology (J.K., U.G., K.S., Y.Z., Y.L., D.S.F., J.L.W., A.V.S., N.Z.), Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA
1 shared publication- Daniel L. Liebman
Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States
1 shared publication - Dolly Shuo-Teh Chang
Genentech, Inc., South San Francisco, California
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Ophthalmology
- Vol. 2026 (1)
Factors Associated With Successful In‐Office Diagnostic Vitreous Aspiration
Background and Objective: To identify demographic, clinical, and procedural factors associated with successful vitreous taps and aspirate volume to optimize candidate selection and technique for this procedure. Study Design/Patients and Methods: We performed a retrospective analysis of patients who underwent in‐office diagnostic vitreous aspiration from January 2010 to December 2022. We reviewed patient demographics, clinical characteristics, and procedural factors and then performed univariate and multivariable regression analyses to identify factors associated with successful vitreous tap and aspirate volume. Results: Among 101 eyes from 101 patients (64% aged 60 years or older, 37.6% female) who received diagnostic vitreous taps in clinic, 77.2% were successfully performed, while the remainder required aqueous sampling. Regression analyses showed that past vitrectomy ( p < 0.001) and smaller needle gauge ( p = 0.001) were associated with successful taps, where eyes with prior vitrectomy had a 100% success rate as compared to 68% in eyes without prior vitrectomy. Interestingly, larger 25‐gauge needles were less successful (68%) than 27‐gauge needles (93%), likely due to documentation of only the largest needle gauge attempted. Eyes that underwent successful vitreous aspiration had a mean aspirate volume of 0.3 ± 0.1 mL, with higher volumes observed in phakic than pseudophakic eyes (0.3 ± 0.1 vs. 0.2 ± 0.1 mL, p = 0.034), as well as those with suspected or actual diagnoses of endogenous versus exogenous infectious uveitis (0.4 vs. 0.2 mL, p = 0.002 and 0.4 vs. 0.2 mL, p = 0.003, respectively). Conclusion: In‐office diagnostic vitreous taps are more likely to be successful in vitrectomized eyes but do not appear to be affected by other factors such as the patient’s age, severity or type of intraocular inflammation, or larger needle gauge.
- 1 January 2026
- Published by Wiley in Journal of Ophthalmology
- Vol. 2026 (1)
Open AccessFactors Associated With Successful In‐Office Diagnostic Vitreous Aspiration
Background and Objective: To identify demographic, clinical, and procedural factors associated with successful vitreous taps and aspirate volume to optimize candidate selection and technique for this procedure. Study Design/Patients and Methods: We performed a retrospective analysis of patients who underwent in‐office diagnostic vitreous aspiration from January 2010 to December 2022. We reviewed patient demographics, clinical characteristics, and procedural factors and then performed univariate and multivariable regression analyses to identify factors associated with successful vitreous tap and aspirate volume. Results: Among 101 eyes from 101 patients (64% aged 60 years or older, 37.6% female) who received diagnostic vitreous taps in clinic, 77.2% were successfully performed, while the remainder required aqueous sampling. Regression analyses showed that past vitrectomy ( p < 0.001) and smaller needle gauge ( p = 0.001) were associated with successful taps, where eyes with prior vitrectomy had a 100% success rate as compared to 68% in eyes without prior vitrectomy. Interestingly, larger 25‐gauge needles were less successful (68%) than 27‐gauge needles (93%), likely due to documentation of only the largest needle gauge attempted. Eyes that underwent successful vitreous aspiration had a mean aspirate volume of 0.3 ± 0.1 mL, with higher volumes observed in phakic than pseudophakic eyes (0.3 ± 0.1 vs. 0.2 ± 0.1 mL, p = 0.034), as well as those with suspected or actual diagnoses of endogenous versus exogenous infectious uveitis (0.4 vs. 0.2 mL, p = 0.002 and 0.4 vs. 0.2 mL, p = 0.003, respectively). Conclusion: In‐office diagnostic vitreous taps are more likely to be successful in vitrectomized eyes but do not appear to be affected by other factors such as the patient’s age, severity or type of intraocular inflammation, or larger needle gauge.
- 19 June 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 267, 204-212
Use of Diagnostic Codes for Primary Open-Angle Glaucoma Polygenic Risk Score Construction in Electronic Health Record–Linked Biobanks
- 19 June 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 267, 204-212
Use of Diagnostic Codes for Primary Open-Angle Glaucoma Polygenic Risk Score Construction in Electronic Health Record–Linked Biobanks
- 12 March 2023
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 6 (5) , 509-520
Comparison of Perimetric Outcomes from a Tablet Perimeter, Smart Visual Function Analyzer, and Humphrey Field Analyzer
- 12 March 2023
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 6 (5) , 509-520
Comparison of Perimetric Outcomes from a Tablet Perimeter, Smart Visual Function Analyzer, and Humphrey Field Analyzer