Jianbo Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianbo Yu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Zebing Zhou
Huazhong University of Science and Technology
6 shared publications - Yanzheng Bai
Huazhong University of Science and Technology
5 shared publications - Bin Mei
Hunan Institute of Technology
4 shared publications - Li Liu
Huazhong University of Science and Technology
4 shared publications - Shaobo Qu
Huazhong University of Science and Technology
4 shared publications - Shuchao Wu
Huazhong University of Science and Technology
4 shared publications
Latest Publications
- 30 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Dynamic range extension and noise evaluation of a high-precision temperature sensor with adaptive switching measuring points
- 30 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Dynamic range extension and noise evaluation of a high-precision temperature sensor with adaptive switching measuring points
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Enhanced suppression of seismic noise effect via active vibration isolation in torsion pendulum testing for space-borne inertial sensors
Precision torsion pendulums can be used to test space-borne inertial sensors with measurement ranges significantly smaller than Earth’s surface gravitational acceleration. In this system, the gravity on the test mass is counterbalanced by the tension of the suspension fiber, enabling the sensor to enter its operational state. Through optimized design configurations, the system can effectively suppress the effects of ultra-low-frequency (around several mHz) seismic noise. This study addresses the mid-to-high frequency ground vibration effects, which conventional torsion pendulum schemes fail to suppress, proposing a novel torsion pendulum testing scheme integrated with an active vibration isolation system. This article introduces the design and theoretical analysis of an inertial sensor testing system with this scheme and shows the experimental validation of the improved seismic effect suppression. The experiments demonstrate that isolating mid-to-high frequency ground vibrations improves the noise floor testing of the inertial sensor, with the measured noise reaching the level of about 2 × 10−10 m/s2/Hz1/2, which reveals the intrinsic noise of the inertial sensor.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Enhanced suppression of seismic noise effect via active vibration isolation in torsion pendulum testing for space-borne inertial sensors
Precision torsion pendulums can be used to test space-borne inertial sensors with measurement ranges significantly smaller than Earth’s surface gravitational acceleration. In this system, the gravity on the test mass is counterbalanced by the tension of the suspension fiber, enabling the sensor to enter its operational state. Through optimized design configurations, the system can effectively suppress the effects of ultra-low-frequency (around several mHz) seismic noise. This study addresses the mid-to-high frequency ground vibration effects, which conventional torsion pendulum schemes fail to suppress, proposing a novel torsion pendulum testing scheme integrated with an active vibration isolation system. This article introduces the design and theoretical analysis of an inertial sensor testing system with this scheme and shows the experimental validation of the improved seismic effect suppression. The experiments demonstrate that isolating mid-to-high frequency ground vibrations improves the noise floor testing of the inertial sensor, with the measured noise reaching the level of about 2 × 10−10 m/s2/Hz1/2, which reveals the intrinsic noise of the inertial sensor.
- 24 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
High-Precision Inertial Sensor Calibration Using Electromagnetic Excitation on an Active Vibration Isolating Bench
High-precision inertial sensors are key instruments in many space science missions, and need to be verified on the ground to ensure that they operate reliably in orbit with the designed accuracy. However, for inertial sensors with accuracy of 10-10 m/s2 or even higher, traditional calibration method put forward higher requirements for facilities and environment, and the test precision level is usually limited by seismic noise. In this study, an electromagnetic excitation calibration method of high-precision inertial sensors is proposed and experimentally verified. The active controlled four-wire pendulum provides a low-noise ground test bench. The driving force required for calibration is generated by the non-contact electromagnetic actuator, which drives the bench to move along the calibration direction. A high-precision electrostatic accelerometer and two commercial seismometers are used for experimental testing and comparison. The experimental results show that the proposed method can realize the sensitivity coefficient calibration, amplitude-frequency response calibration, and resolution calibration of the highvoltage levitation electrostatic accelerometer. The uncertainty of the sensitivity calibration is evaluated to be 0.07%, and the resolution is evaluated to be 2.8×10-10 m/s2 at 0.5 Hz. This work provides a new high-precision dynamic performance test facility for high precision inertial sensors.
- 24 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
High-Precision Inertial Sensor Calibration Using Electromagnetic Excitation on an Active Vibration Isolating Bench
High-precision inertial sensors are key instruments in many space science missions, and need to be verified on the ground to ensure that they operate reliably in orbit with the designed accuracy. However, for inertial sensors with accuracy of 10-10 m/s2 or even higher, traditional calibration method put forward higher requirements for facilities and environment, and the test precision level is usually limited by seismic noise. In this study, an electromagnetic excitation calibration method of high-precision inertial sensors is proposed and experimentally verified. The active controlled four-wire pendulum provides a low-noise ground test bench. The driving force required for calibration is generated by the non-contact electromagnetic actuator, which drives the bench to move along the calibration direction. A high-precision electrostatic accelerometer and two commercial seismometers are used for experimental testing and comparison. The experimental results show that the proposed method can realize the sensitivity coefficient calibration, amplitude-frequency response calibration, and resolution calibration of the highvoltage levitation electrostatic accelerometer. The uncertainty of the sensitivity calibration is evaluated to be 0.07%, and the resolution is evaluated to be 2.8×10-10 m/s2 at 0.5 Hz. This work provides a new high-precision dynamic performance test facility for high precision inertial sensors.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Device for Evaluating the Performance of High-Precision Accelerometers as Motion Sensors for an Active Vibration Isolation System
The high-precision electrostatic accelerometer is the key payload for satellite gravity measurement, so ground testing and verification of its performance is critical. Our group has previously developed a series of test benches that can be used to provide a ground test environment of 10-9 m/s2/Hz1/2 level. In this paper, a novel performance evaluation device for high-precision accelerometers based on an active vibration isolation system is proposed. An electrostatic accelerometer with a theoretical noise level of 10-10 m/s2/Hz1/2 is used as the motion sensor, and the active feedback control is carried out in combination with the four-wire pendulum. The system noise model is further analyzed in detail. The experimental results show that the vibration transmissibility of this system using acceleration sensing is better than that using velocity sensing, which verifies the effectiveness of the proposed method. The total residual noise level on the test bench measured by the seismometer is verified to be about 1×10-9 m/s2/Hz1/2 from 0.5 Hz to 0.8 Hz, while the performance of the electrostatic accelerometer itself is evaluated to be 7×10-10 m/s2/Hz1/2 from 0.3 Hz to 0.6 Hz.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Device for Evaluating the Performance of High-Precision Accelerometers as Motion Sensors for an Active Vibration Isolation System
The high-precision electrostatic accelerometer is the key payload for satellite gravity measurement, so ground testing and verification of its performance is critical. Our group has previously developed a series of test benches that can be used to provide a ground test environment of 10-9 m/s2/Hz1/2 level. In this paper, a novel performance evaluation device for high-precision accelerometers based on an active vibration isolation system is proposed. An electrostatic accelerometer with a theoretical noise level of 10-10 m/s2/Hz1/2 is used as the motion sensor, and the active feedback control is carried out in combination with the four-wire pendulum. The system noise model is further analyzed in detail. The experimental results show that the vibration transmissibility of this system using acceleration sensing is better than that using velocity sensing, which verifies the effectiveness of the proposed method. The total residual noise level on the test bench measured by the seismometer is verified to be about 1×10-9 m/s2/Hz1/2 from 0.5 Hz to 0.8 Hz, while the performance of the electrostatic accelerometer itself is evaluated to be 7×10-10 m/s2/Hz1/2 from 0.3 Hz to 0.6 Hz.
- Open Access
- 1 August 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (8)
Evaluation of microgravity level for the 2.0 s vacuum drop tower at the National Precise Gravity Measurement Facility (PGMF)
The drop tower is an important experimental facility to provide a microgravity environment on the ground. The National Precise Gravity Measurement Facility has built a vacuum drop tower at Wuhan in China. The vacuum drop tower has a falling-height of 20 m, a free falling-time of 2.0 s, and a pressure of ∼6.15 Pa after 1 h pumping. The microgravity level of the vacuum drop tower is analyzed in this paper. The error sources include the aerodynamic drag, the difference of gas pressure around the gaps, the misalignment, the rotation, the magnetic field, etc. The evaluated microgravity level of the vacuum drop tower is better than (4.80 ± 3.31) × 10−7g, which is mainly limited by the aerodynamic drag and the rotation of the capsule. In addition, the microgravity level is measured to be better than 3.22 × 10−5g by using the quartz-flexure accelerometer. The vacuum drop tower provides a ground-based public service platform with a microgravity environment on the order of magnitude of 10−7g for further experiments.
- 1 August 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (8)
Open AccessEvaluation of microgravity level for the 2.0 s vacuum drop tower at the National Precise Gravity Measurement Facility (PGMF)
The drop tower is an important experimental facility to provide a microgravity environment on the ground. The National Precise Gravity Measurement Facility has built a vacuum drop tower at Wuhan in China. The vacuum drop tower has a falling-height of 20 m, a free falling-time of 2.0 s, and a pressure of ∼6.15 Pa after 1 h pumping. The microgravity level of the vacuum drop tower is analyzed in this paper. The error sources include the aerodynamic drag, the difference of gas pressure around the gaps, the misalignment, the rotation, the magnetic field, etc. The evaluated microgravity level of the vacuum drop tower is better than (4.80 ± 3.31) × 10−7g, which is mainly limited by the aerodynamic drag and the rotation of the capsule. In addition, the microgravity level is measured to be better than 3.22 × 10−5g by using the quartz-flexure accelerometer. The vacuum drop tower provides a ground-based public service platform with a microgravity environment on the order of magnitude of 10−7g for further experiments.