AAAbrham Kassa Alem

Abrham Kassa Alem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abrham Kassa Alem has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Bonding Material and Fixing Techniques on the Calibration of Copper–Indium Bimetallic-Coated FBG-Based Cryogenic Temperature Sensors for Aerospace Applications

    by Abrham Kassa Alem, Adriana Morana, Sylvain Girard, Jean-Pierre Chatelon, Peiqing Yu, Minh Chau Phan-Huy, Wendy Tomboza, Santerelli Falzon Tetsing Talla, Francis Vocanson, Fiammetta Fricano, et al.

    To enable fiber Bragg gratings (FBGs) to operate effectively as cryogenic temperature sensors, metals with high thermal expansion coefficients should be deposited onto the surface of an optical fiber. In this work, targeting aerospace applications, a copper–indium bimetallic-coated FBG designed for operation at around 850 nm was manufactured using sputtering and electrodeposition techniques. Furthermore, the influence of bonding materials, specifically Kapton tape and Apiezon N grease, as well as fixation methods, on the performance of the coated FBG was investigated during cryogenic temperature calibration. The results demonstrate that with Kapton tape bonding, the Bragg wavelength shift (BWS) was approximately 1.6 times greater than that obtained with Apiezon N grease at 77 K during sensor calibrations. However, in order to have efficient thermal coupling between the sample holder and the metal-coated sensor in harsh environments such as cryogenic and vacuum environments, the optimal choice of bonding material as well as its architecture is mandatory to achieve high sensor sensitivity. Therefore, this study gives insights into the fact that metal-coated FBGs’ calibration accuracy and real-time stability during sensor deployments can be affected by the fixing techniques and the bonding materials used.

  • Open Access

    Characterization of Radiophotoluminescence Dosimeters Under X-Ray Irradiation at High Doses

    by M. Ferrari, Y. Q. Aguiar, A. Hasan, A. K. Alem, R. García Alía, A. Donzella, D. Pagano, L. Sostero, A. Zenoni, S. Girard

    A characterization of radiophotoluminescence (RPL) dosimeters at high doses of X-ray radiation for applications in high radiation areas is presented. Commercial FD-7 silver doped phosphate glasses (1.5 mm x 8.5 mm) in use at CERN for passive dosimetry are irradiated using commercial X-ray tubes. A 1.5 mm thick aluminium filter is used to harden the X-ray spectrum and improve dose homogeneity. Two irradiation campaigns are presented, targeting doses ranging from about 1.3 kGy to 0.46 MGy and dose rates from about 0.6 kGy/h to 6.3 kGy/h, respectively. Monte Carlo simulations performed with PHITS allowed the determination of a factor to convert the dose to water, into the average absorbed dose to RPL material. The found conversion factor is validated by the achieved measurements. The results evidence a satisfactory agreement between the absorbed doses delivered with X-rays and the readout results, based on Co-60 gamma calibration.