Annelies Van Damme
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Annelies Van Damme has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guylian Stevens
Partnership of Anesthesia, vzw Maria Middelares, Buitenring Sint-Denijs 30, 9000 Ghent, Belgium
2 shared publications - Michiel Larmuseau
AZ Maria Middelares Hospital, Gent, Belgium
2 shared publications - Pascal Verdonck
Ghent University
2 shared publications - Henk Vanoverschelde
Partnership of Anesthesia, AZ Maria Middelares Hospital, Gent, Belgium
1 shared publication - Jan Poelaert
Partnership of Anesthesia, AZ Maria Middelares Hospital, Gent, Belgium
1 shared publication - Jan R. Heerman
Partnership of Anesthesia, AZ Maria Middelares Hospital, Gent, Belgium
1 shared publication
Latest Publications
- 21 September 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 39 (1) , 157-167
An accelerometry and gyroscopy-based system for detecting swallowing and coughing events
Measuring spontaneous swallowing frequencies (SSF), coughing frequencies (CF), and the temporal relationships between swallowing and coughing in patients could provide valuable clinical insights into swallowing function, dysphagia, and the risk of pneumonia development. Medical technology with these capabilities has potential applications in hospital settings. In the management of intensive care unit (ICU) patients, monitoring SSF and CF could contribute to predictive models for successful weaning from ventilatory support, extubation, or tracheal decannulation. Furthermore, the early prediction of pneumonia in hospitalized patients or home care residents could offer additional diagnostic value over current practices. However, existing technologies for measuring SSF and CF, such as electromyography and acoustic sensors, are often complex and challenging to implement in real-world settings. Therefore, there is a need for a simple, flexible, and robust method for these measurements. The primary objective of this study was to develop a system that is both low in complexity and sufficiently flexible to allow for wide clinical applicability. To construct this model, we recruited forty healthy volunteers. Each participant was equipped with two medical-grade sensors (Movesense MD), one attached to the cricoid cartilage and the other positioned in the epigastric region. Both sensors recorded tri-axial accelerometry and gyroscopic movements. Participants were instructed to perform various conscious actions on cue, including swallowing, talking, throat clearing, and coughing. The recorded signals were then processed to create a model capable of accurately identifying conscious swallowing and coughing, while effectively discriminating against other confounding actions. Training of the algorithm resulted in a model with a sensitivity of 70% (14/20), a specificity of 71% (20/28), and a precision of 66.7% (14/21) for the detection of swallowing and, a sensitivity of 100% (20/20), a specificity of 83.3% (25/30), and a precision of 80% (20/25) for the detection of coughing. SSF, CF and the temporal relationship between swallowing and coughing are parameters that could have value as predictive tools for diagnosis and therapeutic guidance. Based on 2 tri-axial accelerometry and gyroscopic sensors, a model was developed with an acceptable sensitivity and precision for the detection of swallowing and coughing movements. Also due to simplicity and robustness of the set-up, the model is promising for further scientific research in a wide range of clinical indications.
- 21 September 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 39 (1) , 157-167
An accelerometry and gyroscopy-based system for detecting swallowing and coughing events
Measuring spontaneous swallowing frequencies (SSF), coughing frequencies (CF), and the temporal relationships between swallowing and coughing in patients could provide valuable clinical insights into swallowing function, dysphagia, and the risk of pneumonia development. Medical technology with these capabilities has potential applications in hospital settings. In the management of intensive care unit (ICU) patients, monitoring SSF and CF could contribute to predictive models for successful weaning from ventilatory support, extubation, or tracheal decannulation. Furthermore, the early prediction of pneumonia in hospitalized patients or home care residents could offer additional diagnostic value over current practices. However, existing technologies for measuring SSF and CF, such as electromyography and acoustic sensors, are often complex and challenging to implement in real-world settings. Therefore, there is a need for a simple, flexible, and robust method for these measurements. The primary objective of this study was to develop a system that is both low in complexity and sufficiently flexible to allow for wide clinical applicability. To construct this model, we recruited forty healthy volunteers. Each participant was equipped with two medical-grade sensors (Movesense MD), one attached to the cricoid cartilage and the other positioned in the epigastric region. Both sensors recorded tri-axial accelerometry and gyroscopic movements. Participants were instructed to perform various conscious actions on cue, including swallowing, talking, throat clearing, and coughing. The recorded signals were then processed to create a model capable of accurately identifying conscious swallowing and coughing, while effectively discriminating against other confounding actions. Training of the algorithm resulted in a model with a sensitivity of 70% (14/20), a specificity of 71% (20/28), and a precision of 66.7% (14/21) for the detection of swallowing and, a sensitivity of 100% (20/20), a specificity of 83.3% (25/30), and a precision of 80% (20/25) for the detection of coughing. SSF, CF and the temporal relationship between swallowing and coughing are parameters that could have value as predictive tools for diagnosis and therapeutic guidance. Based on 2 tri-axial accelerometry and gyroscopic sensors, a model was developed with an acceptable sensitivity and precision for the detection of swallowing and coughing movements. Also due to simplicity and robustness of the set-up, the model is promising for further scientific research in a wide range of clinical indications.
- 19 August 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 39 (1) , 245-256
Feasibility study of the use of a wearable vital sign patch in an intensive care unit setting
Multiple studies and review papers have concluded that early warning systems have a positive effect on clinical outcomes, patient safety and clinical performances. Despite the substantial evidence affirming the efficacy of EWS applications, persistent barriers hinder their seamless integration into clinical practice. Notably, EWS, such as the National Early Warning Score, simplify multifaceted clinical conditions into singular numerical indices, thereby risking the oversight of critical clinical indicators and nuanced fluctuations in patients’ health status. Furthermore, the optimal deployment of EWS within clinical contexts remains elusive. Manual assessment of EWS parameters exacts a significant temporal toll on healthcare personnel. Addressing these impediments necessitates innovative approaches. In this regard, wearable medical technologies emerge as promising solutions capable of continual monitoring of hospitalized patients’ vital signs. To overcome the barriers of the use of early warning scores, wearable medical technology has the potential to continuously monitor vital signs of hospitalised patients. However, a fundamental inquiry arises regarding the comparability of their reliability to the current used golden standards. This inquiry underscores the imperative for rigorous evaluation and validation of wearable medical technologies to ascertain their efficacy in augmenting extant clinical practices. This prospective, single-center study aimed to evaluate the accuracy of heart rate and respiratory rate measurements obtained from the Vivalink Cardiac patch in comparison to the ECG-based monitoring system utilized at AZ Maria Middelares Hospital in Ghent. Specifically, the study focused on assessing the concordance between the data obtained from the Vivalink Cardiac patch and the established ECG-based monitoring system among a cohort of ten post-surgical intensive care unit (ICU) patients. Of these patients, five were undergoing mechanical ventilation post-surgery, while the remaining five were not. The study proceeded by initially comparing the data recorded by the Vivalink Cardiac patch with that of the ECG-based monitoring system. Subsequently, the data obtained from both the Vivalink Cardiac patch and the ECG-based monitoring system were juxtaposed with the information derived from the ventilation machine, thereby providing a comprehensive analysis of the patch’s performance in monitoring vital signs within the ICU setting. For heart rate, the Vivalink Cardiac patch was on average within a 5% error range of the ECG-based monitoring system during 85.11±10.81% of the measured time. For respiratory rate this was during 40.55±17.28% of the measured time. Spearman’s correlation coefficient showed a very high correlation of \(\rho = 0.9\)8 for heart rate and a moderate correlation of \(\rho = 0.66\) for respiratory rate. In comparison with the ventilated respiratory rate (ventilation machine) the Vivalink and ECG-based monitoring system both had a moderate correlation of \(\rho = 0.68.\) A very high correlation was found between the heart rate measured by the Vivalink Cardiac patch and that of the ECG-based monitoring system of the hospital. Concerning respiratory rate the correlation between the data from the Vivalink Cardiac patch, the ECG-based monitoring system and the ventilation machine was found to be moderate.- 19 August 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 39 (1) , 245-256
Feasibility study of the use of a wearable vital sign patch in an intensive care unit setting
Multiple studies and review papers have concluded that early warning systems have a positive effect on clinical outcomes, patient safety and clinical performances. Despite the substantial evidence affirming the efficacy of EWS applications, persistent barriers hinder their seamless integration into clinical practice. Notably, EWS, such as the National Early Warning Score, simplify multifaceted clinical conditions into singular numerical indices, thereby risking the oversight of critical clinical indicators and nuanced fluctuations in patients’ health status. Furthermore, the optimal deployment of EWS within clinical contexts remains elusive. Manual assessment of EWS parameters exacts a significant temporal toll on healthcare personnel. Addressing these impediments necessitates innovative approaches. In this regard, wearable medical technologies emerge as promising solutions capable of continual monitoring of hospitalized patients’ vital signs. To overcome the barriers of the use of early warning scores, wearable medical technology has the potential to continuously monitor vital signs of hospitalised patients. However, a fundamental inquiry arises regarding the comparability of their reliability to the current used golden standards. This inquiry underscores the imperative for rigorous evaluation and validation of wearable medical technologies to ascertain their efficacy in augmenting extant clinical practices. This prospective, single-center study aimed to evaluate the accuracy of heart rate and respiratory rate measurements obtained from the Vivalink Cardiac patch in comparison to the ECG-based monitoring system utilized at AZ Maria Middelares Hospital in Ghent. Specifically, the study focused on assessing the concordance between the data obtained from the Vivalink Cardiac patch and the established ECG-based monitoring system among a cohort of ten post-surgical intensive care unit (ICU) patients. Of these patients, five were undergoing mechanical ventilation post-surgery, while the remaining five were not. The study proceeded by initially comparing the data recorded by the Vivalink Cardiac patch with that of the ECG-based monitoring system. Subsequently, the data obtained from both the Vivalink Cardiac patch and the ECG-based monitoring system were juxtaposed with the information derived from the ventilation machine, thereby providing a comprehensive analysis of the patch’s performance in monitoring vital signs within the ICU setting. For heart rate, the Vivalink Cardiac patch was on average within a 5% error range of the ECG-based monitoring system during 85.11±10.81% of the measured time. For respiratory rate this was during 40.55±17.28% of the measured time. Spearman’s correlation coefficient showed a very high correlation of \(\rho = 0.9\)8 for heart rate and a moderate correlation of \(\rho = 0.66\) for respiratory rate. In comparison with the ventilated respiratory rate (ventilation machine) the Vivalink and ECG-based monitoring system both had a moderate correlation of \(\rho = 0.68.\) A very high correlation was found between the heart rate measured by the Vivalink Cardiac patch and that of the ECG-based monitoring system of the hospital. Concerning respiratory rate the correlation between the data from the Vivalink Cardiac patch, the ECG-based monitoring system and the ventilation machine was found to be moderate.