Zhijie Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhijie Dong has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Andries Meijerink
Debye Institute for Nanomaterials Science, Utrecht University
2 shared publications - Lizhi Cui
National and Local Joint Engineering Laboratory for Optical Conversion Materials and Technology of National Development and Reform Commission, School of Materials and Energy, Lanzhou University, Lanzhou, 730000, China
2 shared publications - Yuhua Wang
Lanzhou University
2 shared publications - Dechao Yu
Engineering Research Center of Optical Instrument and System, Ministry of Education and Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
1 shared publication - Guitong Zhang
National and Local Joint Engineering Laboratory for Optical Conversion Materials and Technology of National Development and Reform Commission, School of Materials and Energy, Lanzhou University, Lanzhou, 730000, China
1 shared publication - JiaPeng Wu
National and Local Joint Engineering Laboratory for Optical Conversion Materials and Technology of National Development and Reform Commission, School of Materials and Energy, Lanzhou University, Lanzhou, 730000, China
1 shared publication
Latest Publications
- 16 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (42) , eaeh4432
Exploring calibration-free luminescence thermometry with Mn 4+ anti-Stokes/Stokes emission
Mn 4+ -activated phosphors offer a unique possibility of calibration-free primary luminescence thermometry using the ratio of anti-Stokes to Stokes (AS/S) vibronic emission lines of the 2 E → 4 A 2 transition. Previous work used the AS/S emission of Mn 4+ for thermometry but always relying on fitting procedures with effective vibrational energies that deviate from actual energies. Here, we explore a strategy without prior temperature calibration using two well-known Mn 4+ -doped hosts, Mg 14 Ge 5 O 24 (MGO) and K 2 SiF 6 (KSF). In both Mn 4+ occupies octahedral sites, replacing Ge 4+ or Si 4+ , resulting in a weak zero-phonon line (ZPL) and strong vibronic Stokes and anti-Stokes lines. From the temperature-dependent emission spectra the AS/S ratios ν 6 ′/ν 6 , ν 4 ′/ν 4 , ν 3 ′/ν 3 were determined to serve as input for luminescence intensity ratio (LIR) analysis. For the well-resolved vibronic lines of Mn 4+ in KSF it is feasible to realize temperature readout without temperature calibration – a capability rarely achieved in luminescence thermometry. In contrast, for Mn 4+ in MGO vibronic lines exhibit significant overlap, complicating single-phonon-mode modeling. Even spectral deconvolution methods do not allow for reliable calibration-free temperature sensing. This work establishes a generalizable approach to optical thermometry relying on anti-Stokes/Stokes vibronic lines, offering a path towards calibration-free temperature sensing.
- 16 October 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (42) , eaeh4432
Exploring calibration-free luminescence thermometry with Mn 4+ anti-Stokes/Stokes emission
Mn 4+ -activated phosphors offer a unique possibility of calibration-free primary luminescence thermometry using the ratio of anti-Stokes to Stokes (AS/S) vibronic emission lines of the 2 E → 4 A 2 transition. Previous work used the AS/S emission of Mn 4+ for thermometry but always relying on fitting procedures with effective vibrational energies that deviate from actual energies. Here, we explore a strategy without prior temperature calibration using two well-known Mn 4+ -doped hosts, Mg 14 Ge 5 O 24 (MGO) and K 2 SiF 6 (KSF). In both Mn 4+ occupies octahedral sites, replacing Ge 4+ or Si 4+ , resulting in a weak zero-phonon line (ZPL) and strong vibronic Stokes and anti-Stokes lines. From the temperature-dependent emission spectra the AS/S ratios ν 6 ′/ν 6 , ν 4 ′/ν 4 , ν 3 ′/ν 3 were determined to serve as input for luminescence intensity ratio (LIR) analysis. For the well-resolved vibronic lines of Mn 4+ in KSF it is feasible to realize temperature readout without temperature calibration – a capability rarely achieved in luminescence thermometry. In contrast, for Mn 4+ in MGO vibronic lines exhibit significant overlap, complicating single-phonon-mode modeling. Even spectral deconvolution methods do not allow for reliable calibration-free temperature sensing. This work establishes a generalizable approach to optical thermometry relying on anti-Stokes/Stokes vibronic lines, offering a path towards calibration-free temperature sensing.
- Open Access
- 16 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (33) , eado7737
High-sensitivity luminescent temperature sensors: MFX:1%Sm 2+ (M = Sr, Ba, X = Cl, Br)
The use of lanthanide luminescence has advanced the field of remote temperature sensing. Luminescence intensity ratio methods relying on emission from two thermally coupled energy levels are popular but suffer from a limited temperature range. Here, we present a versatile luminescent thermometer: Ba(Sr)FBr(Cl):Sm 2+ . The Sm 2+ ion benefits from multiple thermally coupled excited states to extend the temperature range and has strong parity-allowed 4f 6 →4f 5 5d 1 absorption to increase brightness. We conduct a comparative analysis of the temperature sensing performance of Sm 2+ in BaFBr, BaFCl, SrFBr, and SrFCl and address the role of concentration, host, and Boltzmann equilibration. Different thermal coupling schemes, 5 D 1 - 5 D 0 and 4f 5 5d 1 - 5 D 0 , and temperature-dependent lifetimes enable accurate sensing between 350 and 800 kelvin. Differences in 4f 5 5d 1 - 5 D 0 energy gap allows optimization for a temperature range of interest. This type of Sm 2+ -based thermometer holds great potential for temperature monitoring in the wide and relevant range up to 500°C.
- 16 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (33) , eado7737
Open AccessHigh-sensitivity luminescent temperature sensors: MFX:1%Sm 2+ (M = Sr, Ba, X = Cl, Br)
The use of lanthanide luminescence has advanced the field of remote temperature sensing. Luminescence intensity ratio methods relying on emission from two thermally coupled energy levels are popular but suffer from a limited temperature range. Here, we present a versatile luminescent thermometer: Ba(Sr)FBr(Cl):Sm 2+ . The Sm 2+ ion benefits from multiple thermally coupled excited states to extend the temperature range and has strong parity-allowed 4f 6 →4f 5 5d 1 absorption to increase brightness. We conduct a comparative analysis of the temperature sensing performance of Sm 2+ in BaFBr, BaFCl, SrFBr, and SrFCl and address the role of concentration, host, and Boltzmann equilibration. Different thermal coupling schemes, 5 D 1 - 5 D 0 and 4f 5 5d 1 - 5 D 0 , and temperature-dependent lifetimes enable accurate sensing between 350 and 800 kelvin. Differences in 4f 5 5d 1 - 5 D 0 energy gap allows optimization for a temperature range of interest. This type of Sm 2+ -based thermometer holds great potential for temperature monitoring in the wide and relevant range up to 500°C.