Tsungom Mulai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tsungom Mulai has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- John Elisa Kumar
Department of Chemistry, North-Eastern Hill University, Shillong, India
5 shared publications - Mihir Kumar Sahoo
Department of Chemistry North Eastern Hill University Shillong Meghalaya India
5 shared publications - Ashutosh Tripathy
Department of Food Engineering and Technology, Institute of Chemical Technology, Mumbai, India
2 shared publications - Ibakorlang Lapasam
Department of Chemistry North Eastern Hill University Shillong Meghalaya India
2 shared publications - Wanshanlang Kharmawphlang
Department of Chemistry North‐Eastern Hill University Shillong 793 022 India
2 shared publications Ibakorlang Lapasam
1 shared publication
Latest Publications
- Open Access
- 26 February 2026
- Published by Springer Nature in Discover Electrochemistry
- Vol. 3 (1) , 27
Replacing hydrogen peroxide in Fenton oxidation by calcium peroxide for degradation of persistent organic pollutants
- 26 February 2026
- Published by Springer Nature in Discover Electrochemistry
- Vol. 3 (1) , 27
Open AccessReplacing hydrogen peroxide in Fenton oxidation by calcium peroxide for degradation of persistent organic pollutants
- 28 November 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (45)
NaOCl and UVC Mediated Heterogeneous Fenton Type Processes for Efficient COD Removal of Acid Orange 8
This study investigates the removal of chemical oxygen demand (COD) and color from Acid Orange 8 (AO8) using heterogeneous and photo‐Fenton‐type processes. Two catalysts, nano‐ferrite ( n ‐Fe 2 O 3 ) and pyrite (FeS 2 ), were employed with NaOCl as the oxidant, both under dark and UV‐illuminated conditions. Under optimized parameters ([ n ‐Fe 2 O 3 ] = 4.0 g L −1 ; [FeS 2 ] = 2.0 g L −1 ; [NaOCl] = 2.5 mM; pH = 3.0; equilibrium period = 30 min), n ‐Fe 2 O 3 /NaOCl achieved a higher initial COD removal (91.3% at 5 min) compared to FeS 2 /NaOCl (72.8%). However, UV‐assisted systems exhibited superior performance, with FeS 2 /NaOCl/UV and n ‐Fe 2 O 3 /NaOCl/UV, achieving complete COD removal within 60 and 120 min, respectively, as opposed to 300 min for non‐UV systems. The presence of SO 4 2− , NO 3 − , Cl − , and Br − inhibited COD removal, whereas F − enhanced it in the n ‐Fe 2 O 3 /NaOCl system. Kinetic analysis revealed that the Behnajady–Modirshahla–Ghanbary (BMG) model best described the degradation behavior. Among all combinations, the FeS 2 /NaOCl/UV system demonstrated the highest synergistic effect and cost efficiency, achieving nearly 100% COD removal. Mechanistic studies indicated that both HO • and Fe(IV) were major contributors in n ‐Fe 2 O 3 ‐based systems, while Fe(IV) dominated in FeS 2 ‐based systems, followed by HO • and reactive chlorine species (RCS), accounting for its superior efficiency.
- 28 November 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (45)
NaOCl and UVC Mediated Heterogeneous Fenton Type Processes for Efficient COD Removal of Acid Orange 8
This study investigates the removal of chemical oxygen demand (COD) and color from Acid Orange 8 (AO8) using heterogeneous and photo‐Fenton‐type processes. Two catalysts, nano‐ferrite ( n ‐Fe 2 O 3 ) and pyrite (FeS 2 ), were employed with NaOCl as the oxidant, both under dark and UV‐illuminated conditions. Under optimized parameters ([ n ‐Fe 2 O 3 ] = 4.0 g L −1 ; [FeS 2 ] = 2.0 g L −1 ; [NaOCl] = 2.5 mM; pH = 3.0; equilibrium period = 30 min), n ‐Fe 2 O 3 /NaOCl achieved a higher initial COD removal (91.3% at 5 min) compared to FeS 2 /NaOCl (72.8%). However, UV‐assisted systems exhibited superior performance, with FeS 2 /NaOCl/UV and n ‐Fe 2 O 3 /NaOCl/UV, achieving complete COD removal within 60 and 120 min, respectively, as opposed to 300 min for non‐UV systems. The presence of SO 4 2− , NO 3 − , Cl − , and Br − inhibited COD removal, whereas F − enhanced it in the n ‐Fe 2 O 3 /NaOCl system. Kinetic analysis revealed that the Behnajady–Modirshahla–Ghanbary (BMG) model best described the degradation behavior. Among all combinations, the FeS 2 /NaOCl/UV system demonstrated the highest synergistic effect and cost efficiency, achieving nearly 100% COD removal. Mechanistic studies indicated that both HO • and Fe(IV) were major contributors in n ‐Fe 2 O 3 ‐based systems, while Fe(IV) dominated in FeS 2 ‐based systems, followed by HO • and reactive chlorine species (RCS), accounting for its superior efficiency.
- 26 June 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (25)
COD Removal of Pine Cone‐Contaminated Water by Fenton and Fenton‐Type Processes Using Different Oxidants
The accumulation of pine tree components, which contain organic compounds like tannins, cellulose, and lignin, in water bodies can lead to an increase in chemical oxygen demand (COD). This study investigates the COD removal from pine cone‐contaminated water (PCW) using Fenton oxidation with various oxidants, including sodium persulfate (SPS), sodium perborate (SPB), and hydrogen peroxide (HP). The results show that the Fe 2+ /SPB and Fe 2+ /HP systems achieved COD removal efficiency (COD eff ) of 60.0 and 51.6%, respectively, after 300 min at pH 3. In contrast, the Fe 2+ /SPS system exhibited COD eff of 41.5 and 57.8% at pH 3 and 5.4 (pH of PCW), respectively. The oxidant efficiency followed the order: SPB >HP >SPS at pH 3, suggesting that SPB can be considered as a substitute for HP in Fenton oxidation. Remarkably, complete COD removal was achieved in 120 min with UV 254 light. Anion inhibition studies revealed that Br − completely inhibited COD eff , while , Cl − showed lesser inhibition. The inhibition of , and F − was pH‐dependent and influenced by the oxidant used. Kinetic analysis indicated that the Fe 2+ /HP system followed first‐order kinetics, whereas the Fe 2+ /SPS and Fe 2+ /SPB systems followed second‐order kinetics. Notably, the Fe 2+ /SPS system at pH 5.4 followed the Behnajady–Modirshahla–Ghanbery kinetic model.
- 26 June 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (25)
COD Removal of Pine Cone‐Contaminated Water by Fenton and Fenton‐Type Processes Using Different Oxidants
The accumulation of pine tree components, which contain organic compounds like tannins, cellulose, and lignin, in water bodies can lead to an increase in chemical oxygen demand (COD). This study investigates the COD removal from pine cone‐contaminated water (PCW) using Fenton oxidation with various oxidants, including sodium persulfate (SPS), sodium perborate (SPB), and hydrogen peroxide (HP). The results show that the Fe 2+ /SPB and Fe 2+ /HP systems achieved COD removal efficiency (COD eff ) of 60.0 and 51.6%, respectively, after 300 min at pH 3. In contrast, the Fe 2+ /SPS system exhibited COD eff of 41.5 and 57.8% at pH 3 and 5.4 (pH of PCW), respectively. The oxidant efficiency followed the order: SPB >HP >SPS at pH 3, suggesting that SPB can be considered as a substitute for HP in Fenton oxidation. Remarkably, complete COD removal was achieved in 120 min with UV 254 light. Anion inhibition studies revealed that Br − completely inhibited COD eff , while , Cl − showed lesser inhibition. The inhibition of , and F − was pH‐dependent and influenced by the oxidant used. Kinetic analysis indicated that the Fe 2+ /HP system followed first‐order kinetics, whereas the Fe 2+ /SPS and Fe 2+ /SPB systems followed second‐order kinetics. Notably, the Fe 2+ /SPS system at pH 5.4 followed the Behnajady–Modirshahla–Ghanbery kinetic model.
- 20 June 2025
- Published by Elsevier in Next Research
- Vol. 2 (3)
Degradation of higher concentration of food colouring dye by classical fenton oxidation: A statistical optimization
- 20 June 2025
- Published by Elsevier in Next Research
- Vol. 2 (3)
Degradation of higher concentration of food colouring dye by classical fenton oxidation: A statistical optimization
- 30 May 2025
- Published by Elsevier in Next Research
- Vol. 2 (3)
Hydroxyl and sulphate radical based homogeneous and heterogeneous oxidative COD removal of dye mixtures: kinetics, and toxicity assessment
- 30 May 2025
- Published by Elsevier in Next Research
- Vol. 2 (3)
Hydroxyl and sulphate radical based homogeneous and heterogeneous oxidative COD removal of dye mixtures: kinetics, and toxicity assessment
- 14 August 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (31)
Metal‐Ion and UVC Light‐Catalyzed Oxidation and Biodetoxification of Ponceau Xylidine in Aqueous Solution: A Comparative Study
Metal ion ( /oxidant) and UV light catalyzed (UV/oxidant) mineralization and biodetoxification of Ponceau Xylidine (PX) was undertaken in this study. Hydrogen peroxide (HP) and ammonium persulphate (APS) were employed as oxidants and and as metal ion catalysts. Although highest mineralization in /APS and UV/HP systems was exhibited at pH 1 (63.09 %) and 3 (64.83 %), respectively, lowest was shown by /oxidant systems at any pH. The Fenton process achieved mineralization of ≈48.50 % within the pH range of 3 to 6.15. The study established as a better catalyst than , and HP, a better oxidant (2.5 times more effective) than APS. Mineralization with UV/HP at 120 min is highest at pH 3 (92.0 %) and 6.15 (86.17 %). Various inorganic anions were found to inhibit mineralization. The maximum and minimum inhibition was shown by in UV/HP and UV/APS systems respectively. The inhibition effect of decreases with concentration till 0.01 mM, beyond which an increasing trend was observed. This study also demonstrates that the biodetoxification efficiency of various systems is in the order: UV/HP>UV/APS> /HP. Thus, UV/HP is the most suitable system for the treatment of PX, displaying a biodetoxification efficiency of 83.0 % and mineralization of 92.0 %.
- 14 August 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (31)
Metal‐Ion and UVC Light‐Catalyzed Oxidation and Biodetoxification of Ponceau Xylidine in Aqueous Solution: A Comparative Study
Metal ion ( /oxidant) and UV light catalyzed (UV/oxidant) mineralization and biodetoxification of Ponceau Xylidine (PX) was undertaken in this study. Hydrogen peroxide (HP) and ammonium persulphate (APS) were employed as oxidants and and as metal ion catalysts. Although highest mineralization in /APS and UV/HP systems was exhibited at pH 1 (63.09 %) and 3 (64.83 %), respectively, lowest was shown by /oxidant systems at any pH. The Fenton process achieved mineralization of ≈48.50 % within the pH range of 3 to 6.15. The study established as a better catalyst than , and HP, a better oxidant (2.5 times more effective) than APS. Mineralization with UV/HP at 120 min is highest at pH 3 (92.0 %) and 6.15 (86.17 %). Various inorganic anions were found to inhibit mineralization. The maximum and minimum inhibition was shown by in UV/HP and UV/APS systems respectively. The inhibition effect of decreases with concentration till 0.01 mM, beyond which an increasing trend was observed. This study also demonstrates that the biodetoxification efficiency of various systems is in the order: UV/HP>UV/APS> /HP. Thus, UV/HP is the most suitable system for the treatment of PX, displaying a biodetoxification efficiency of 83.0 % and mineralization of 92.0 %.