Malgorzata Lalak-Dybała
Malgorzata Lalak-Dybała has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Paweł Olszewski
WSEI University, Lublin, Poland and Poland Research and Development Center, Netrix S.A., Lublin, Poland
2 shared publications - Arkadiusz Małek
Department of Transportation and Informatics, WSEI University, 20-209 Lublin, Poland
1 shared publication - Barbara Stefaniak
WSEI University, Lublin, Poland
1 shared publication - Bartosz Przysucha
Faculty of Management, Lublin University of Technology, 20-618 Lublin, Poland
1 shared publication - Paweł Tchórzewski
R&D Center Netrix S.A., Lublin, Poland
1 shared publication - Przemysław Adamkiewicz
University of Economics and Innovation, Lublin, Poland
1 shared publication
Latest Publications
- Open Access
- 20 August 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 57 (3) , 594-608
Analysis of the effectiveness of two different loss functions in training a neural network in lung image reconstruction using impedance tomography
The article presents research findings on developing a medical diagnostic system based on electrical impedance tomography technology. One of the key components of this project is developing a method for reconstructing the structure of human lungs using this technology. The authors of the article compared the effectiveness of two different loss functions in training a neural network, which is tasked with accurately replicating the lung structure based on electrical impedance tomography data. The researchers analyzed various approaches to calculating loss functions, including cosine embedding loss and InfoNCE loss. They compared the results obtained using these two functions to identify which one performs better in lung structure reconstruction. The findings of these studies may have significant implications for the development of diagnostic systems based on electrical impedance tomography and for improving the effectiveness of lung disease diagnosis. Additionally, the authors discuss potential future directions for the project, including possible applications of the research findings in clinical practice. Future research efforts may focus on optimizing neural network parameters, exploring alternative loss functions, or utilizing advanced machine learning techniques for even more precise lung structure reconstruction. The pursuit of improving such diagnostic systems could lead to significant advancements in the field of medicine, particularly in diagnosing and treating respiratory diseases.
- 20 August 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 57 (3) , 594-608
Open AccessAnalysis of the effectiveness of two different loss functions in training a neural network in lung image reconstruction using impedance tomography
The article presents research findings on developing a medical diagnostic system based on electrical impedance tomography technology. One of the key components of this project is developing a method for reconstructing the structure of human lungs using this technology. The authors of the article compared the effectiveness of two different loss functions in training a neural network, which is tasked with accurately replicating the lung structure based on electrical impedance tomography data. The researchers analyzed various approaches to calculating loss functions, including cosine embedding loss and InfoNCE loss. They compared the results obtained using these two functions to identify which one performs better in lung structure reconstruction. The findings of these studies may have significant implications for the development of diagnostic systems based on electrical impedance tomography and for improving the effectiveness of lung disease diagnosis. Additionally, the authors discuss potential future directions for the project, including possible applications of the research findings in clinical practice. Future research efforts may focus on optimizing neural network parameters, exploring alternative loss functions, or utilizing advanced machine learning techniques for even more precise lung structure reconstruction. The pursuit of improving such diagnostic systems could lead to significant advancements in the field of medicine, particularly in diagnosing and treating respiratory diseases.
- Open Access
- 20 August 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 57 (3) , 783-802
The use of non-invasive tomographic imaging to monitor lung condition
The development of ultrasound tomography (UST) aimed to significantly enhance the precision and safety of non-invasive UST imaging, particularly for studying crystallization processes in biological tissues. The initiative sought to address the limitations of previous versions by incorporating advanced technological upgrades and providing a more user-friendly interface. The revised system comprises eight four-channel measurement cards interconnected via a high-speed FD CAN bus capable of 8 MBPS data transfer. Each card features a dedicated square wave generator, band-pass filters tailored to specific ultrasonic transducer frequencies, and a sophisticated signal envelope processing unit. The core processing unit is built around a 32-bit STM32G474RE microcontroller, ensuring robust data handling and image reconstruction capabilities. The UST device presented demonstrates improved image clarity and reduced noise interference. The measurement card redesign has achieved a sampling rate of 4 MBPS per channel and includes a two-stage amplification for dynamic range management. Upgraded power components, comprehensive shielding, and the integration of advanced analog switches have led to an enhanced signal-to-noise ratio, pivotal for high-resolution imaging. The advancements presented in the UST device mark a noteworthy progression in ultrasound imaging technology, extending beyond traditional applications. High-speed data collection, precise signal processing, and user-centered design have all come together to make a system that can image crystallization processes more accurately and accurately over and over again.
- 20 August 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 57 (3) , 783-802
Open AccessThe use of non-invasive tomographic imaging to monitor lung condition
The development of ultrasound tomography (UST) aimed to significantly enhance the precision and safety of non-invasive UST imaging, particularly for studying crystallization processes in biological tissues. The initiative sought to address the limitations of previous versions by incorporating advanced technological upgrades and providing a more user-friendly interface. The revised system comprises eight four-channel measurement cards interconnected via a high-speed FD CAN bus capable of 8 MBPS data transfer. Each card features a dedicated square wave generator, band-pass filters tailored to specific ultrasonic transducer frequencies, and a sophisticated signal envelope processing unit. The core processing unit is built around a 32-bit STM32G474RE microcontroller, ensuring robust data handling and image reconstruction capabilities. The UST device presented demonstrates improved image clarity and reduced noise interference. The measurement card redesign has achieved a sampling rate of 4 MBPS per channel and includes a two-stage amplification for dynamic range management. Upgraded power components, comprehensive shielding, and the integration of advanced analog switches have led to an enhanced signal-to-noise ratio, pivotal for high-resolution imaging. The advancements presented in the UST device mark a noteworthy progression in ultrasound imaging technology, extending beyond traditional applications. High-speed data collection, precise signal processing, and user-centered design have all come together to make a system that can image crystallization processes more accurately and accurately over and over again.
- Open Access
- 20 August 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 57 (3) , 622-636
Use of electrical impedance tomography for lung volume reconstruction
The article presents a study of the application of electro-impedance tomography (EIT) in diagnosing lung capacity using the Tikhonov regularization method. The possibility of reconstructing the lungs to monitor the degree of air filling was investigated. The experiment included a series of tests using a torso phantom designed to simulate different states of the lungs - from fully inflated to fully deflated. Lung-filling states were manipulated in controlled scenarios to test nine main experimental conditions reflecting different lung-filling states. In addition, the quality of reconstruction was checked using various types of reference backgrounds. The results show significant differences in lung volume reconstructions depending on the lung filling state. The most successful reconstructions, which were obtained using the 'No phantom' background, provided the most explicit visualization of the lungs, reassuring the method's reliability. The experiments confirm the potential of EIT to distinguish between different lung states and reconstruct the degree of lung filling. The study also underscores the need to optimize the reference background to increase the precision of the images, especially for the left lung.
- 20 August 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 57 (3) , 622-636
Open AccessUse of electrical impedance tomography for lung volume reconstruction
The article presents a study of the application of electro-impedance tomography (EIT) in diagnosing lung capacity using the Tikhonov regularization method. The possibility of reconstructing the lungs to monitor the degree of air filling was investigated. The experiment included a series of tests using a torso phantom designed to simulate different states of the lungs - from fully inflated to fully deflated. Lung-filling states were manipulated in controlled scenarios to test nine main experimental conditions reflecting different lung-filling states. In addition, the quality of reconstruction was checked using various types of reference backgrounds. The results show significant differences in lung volume reconstructions depending on the lung filling state. The most successful reconstructions, which were obtained using the 'No phantom' background, provided the most explicit visualization of the lungs, reassuring the method's reliability. The experiments confirm the potential of EIT to distinguish between different lung states and reconstruct the degree of lung filling. The study also underscores the need to optimize the reference background to increase the precision of the images, especially for the left lung.