Chunhui Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chunhui Yao has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Qixiang Cheng
Electrical Engineering Division Department of Engineering University of Cambridge Cambridge UK
6 shared publications Jie Ma
GlitterinTech Limited, Xuzhou, China
4 shared publicationsRichard Penty
Department of Engineering, University of Cambridge, Cambridge, UK
4 shared publicationsTing Yan
GlitterinTech Limited, Xuzhou, China
4 shared publicationsLiang Ming
GlitterinTech Limited, Xuzhou, China
3 shared publications- Minjia Chen
Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK
3 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by Springer Nature in Nature Photonics
- Vol. 20 (6) , 664-672
Optical convolutional spectrometer
Optical spectrometers are fundamental across numerous disciplines. However, miniaturized versions, while essential for in situ measurements, are often restricted to coarse identification of signature peaks and are inadequate for metrological purposes. Here we introduce a new class of spectrometer, which uses the convolution theorem as its unique mathematical foundation. Our ‘convolutional spectrometer’ offers unmatched performance for miniaturized systems and distinct structural and computational simplicity, featuring a centimetre-scale footprint for the fully packaged unit, low cost (~US$10) and a 2,400 cm −1 (approximately 500 nm) bandwidth in the near-infrared region. We achieve excellent precision in resolving complex spectra with subsecond sampling and processing time, demonstrating wide near-infrared spectroscopic applications from industrial and agricultural analysis to healthcare monitoring. Specifically, our spectrometer system classifies diverse solid samples, including plastics, pharmaceuticals, coffee, flour and tea, with 100% success rate, and quantifies concentrations of aqueous and organic solutions with detection accuracy surpassing commercial benchtop spectrometers. We also realize the non-invasive sensing of human biomarkers, such as skin moisture (mean absolute error = 2.49%), blood alcohol (1.70 mg dl −1 ), blood lactate (0.81 mmol l −1 ) and blood glucose (0.36 mmol l −1 ), highlighting the potential of this new class of spectrometers for low-cost, high-precision, portable and/or wearable spectral metrology.
- 15 April 2026
- Published by Springer Nature in Nature Photonics
- Vol. 20 (6) , 664-672
Open AccessOptical convolutional spectrometer
Optical spectrometers are fundamental across numerous disciplines. However, miniaturized versions, while essential for in situ measurements, are often restricted to coarse identification of signature peaks and are inadequate for metrological purposes. Here we introduce a new class of spectrometer, which uses the convolution theorem as its unique mathematical foundation. Our ‘convolutional spectrometer’ offers unmatched performance for miniaturized systems and distinct structural and computational simplicity, featuring a centimetre-scale footprint for the fully packaged unit, low cost (~US$10) and a 2,400 cm −1 (approximately 500 nm) bandwidth in the near-infrared region. We achieve excellent precision in resolving complex spectra with subsecond sampling and processing time, demonstrating wide near-infrared spectroscopic applications from industrial and agricultural analysis to healthcare monitoring. Specifically, our spectrometer system classifies diverse solid samples, including plastics, pharmaceuticals, coffee, flour and tea, with 100% success rate, and quantifies concentrations of aqueous and organic solutions with detection accuracy surpassing commercial benchtop spectrometers. We also realize the non-invasive sensing of human biomarkers, such as skin moisture (mean absolute error = 2.49%), blood alcohol (1.70 mg dl −1 ), blood lactate (0.81 mmol l −1 ) and blood glucose (0.36 mmol l −1 ), highlighting the potential of this new class of spectrometers for low-cost, high-precision, portable and/or wearable spectral metrology.
- Open Access
- 11 February 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (12)
3D Surface Profiling via Direct End‐to‐End Regression With a Photonic Geometric Sensor
Measurements of microscale surface patterns are essential for process and quality control in industries across semiconductors, micro‐machining, and biomedicine. However, the development of miniaturized and intelligent profiling systems remains a longstanding challenge, primarily due to the complexity and bulkiness of existing benchtop systems required to scan large‐area samples. A real‐time, in situ, and fast detection alternative is therefore highly desirable for predicting surface topography on the fly. In this paper, we present an ultracompact geometric profiler based on photonic integrated circuits, which directly encodes the optical reflectance of the sample and decodes it with a neural network. This scheme avoids explicit recovery of complex interferometric spectra and the associated fitting algorithms. We show that an integrated programmable circuit can generate pseudo‐random kernels to project input data into higher dimensions, enabling efficient feature extraction via a lightweight one‐dimensional convolutional neural network. Our device is capable of reliable, fast‐scanning‐rate thickness identification for both smoothly varying samples and intricate 3D printed emblem structures, paving the way for a new class of compact geometric sensors.
- 11 February 2026
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (12)
Open Access3D Surface Profiling via Direct End‐to‐End Regression With a Photonic Geometric Sensor
Measurements of microscale surface patterns are essential for process and quality control in industries across semiconductors, micro‐machining, and biomedicine. However, the development of miniaturized and intelligent profiling systems remains a longstanding challenge, primarily due to the complexity and bulkiness of existing benchtop systems required to scan large‐area samples. A real‐time, in situ, and fast detection alternative is therefore highly desirable for predicting surface topography on the fly. In this paper, we present an ultracompact geometric profiler based on photonic integrated circuits, which directly encodes the optical reflectance of the sample and decodes it with a neural network. This scheme avoids explicit recovery of complex interferometric spectra and the associated fitting algorithms. We show that an integrated programmable circuit can generate pseudo‐random kernels to project input data into higher dimensions, enabling efficient feature extraction via a lightweight one‐dimensional convolutional neural network. Our device is capable of reliable, fast‐scanning‐rate thickness identification for both smoothly varying samples and intricate 3D printed emblem structures, paving the way for a new class of compact geometric sensors.
- 5 July 2025
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 616
Emissivity of post-corrosion stainless steel 316 exposed to FLiBe molten salt in a non-isothermal flow loop
- 5 July 2025
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 616
Emissivity of post-corrosion stainless steel 316 exposed to FLiBe molten salt in a non-isothermal flow loop
- Open Access
- 3 April 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-10
Ultra-low-crosstalk silicon switches driven thermally and electrically
Silicon photonic switches are widely considered as a cost-effective solution for addressing the ever-growing data traffic in datacenter networks, as they offer unique advantages such as low power consumption, low latency, small footprint and high bandwidth. Despite extensive research efforts, crosstalk in large-scale photonic circuits still poses a threat to signal integrity. In this paper, we present two designs of silicon Mach-Zehnder Interferometer (MZI) switches achieving ultra-low-crosstalk, driven thermally and electrically. Each switch fabric is optimized at both the device and circuit level to suppress crosstalk and reduce system complexity. Notably, for the first time to the best of our knowledge, we harness the inherent self-heating effect in a carrier-injection-based MZI switch to create a pair of phase shifters that offers arbitrary phase differences. Such a pair of phase shifters induces matched insertion loss at each arm, thus minimizing crosstalk. Experimentally, an ultra-low crosstalk ratio below −40 dB is demonstrated for both thermo-optic (T-O) and electro-optic (E-O) switches. The T-O switch exhibits an on-chip loss of less than 5 dB with a switching time of 500 µs, whereas the E-O switch achieves an on-chip loss as low as 8.5 dB with a switching time of under 100 ns. In addition, data transmission of a 50 Gb/s on–off keying signal is demonstrated with high fidelity on the E-O switch, showing the great potential of the proposed switch designs.
- 3 April 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-10
Open AccessUltra-low-crosstalk silicon switches driven thermally and electrically
Silicon photonic switches are widely considered as a cost-effective solution for addressing the ever-growing data traffic in datacenter networks, as they offer unique advantages such as low power consumption, low latency, small footprint and high bandwidth. Despite extensive research efforts, crosstalk in large-scale photonic circuits still poses a threat to signal integrity. In this paper, we present two designs of silicon Mach-Zehnder Interferometer (MZI) switches achieving ultra-low-crosstalk, driven thermally and electrically. Each switch fabric is optimized at both the device and circuit level to suppress crosstalk and reduce system complexity. Notably, for the first time to the best of our knowledge, we harness the inherent self-heating effect in a carrier-injection-based MZI switch to create a pair of phase shifters that offers arbitrary phase differences. Such a pair of phase shifters induces matched insertion loss at each arm, thus minimizing crosstalk. Experimentally, an ultra-low crosstalk ratio below −40 dB is demonstrated for both thermo-optic (T-O) and electro-optic (E-O) switches. The T-O switch exhibits an on-chip loss of less than 5 dB with a switching time of 500 µs, whereas the E-O switch achieves an on-chip loss as low as 8.5 dB with a switching time of under 100 ns. In addition, data transmission of a 50 Gb/s on–off keying signal is demonstrated with high fidelity on the E-O switch, showing the great potential of the proposed switch designs.
- Open Access
- 3 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Asymmetrical estimator for training encapsulated deep photonic neural networks
Photonic neural networks (PNNs) are fast in-propagation and high bandwidth paradigms that aim to popularize reproducible NN acceleration with higher efficiency and lower cost. However, the training of PNN is known to be challenging, where the device-to-device and system-to-system variations create imperfect knowledge of the PNN. Despite backpropagation (BP)-based training algorithms being the industry standard for their robustness, generality, and fast gradient convergence for digital training, existing PNN-BP methods rely heavily on accurate intermediate state extraction or extensive computational resources for deep PNNs (DPNNs). The truncated photonic signal propagation and the computation overhead bottleneck DPNN’s operation efficiency and increase system construction cost. Here, we introduce the asymmetrical training (AsyT) method, tailored for encapsulated DPNNs, where the signal is preserved in the analogue photonic domain for the entire structure. AsyT offers a lightweight solution for DPNNs with minimum readouts, fast and energy-efficient operation, and minimum system footprint. AsyT’s ease of operation, error tolerance, and generality aim to promote PNN acceleration in a widened operational scenario despite the fabrication variations and imperfect controls. We demonstrated AsyT for encapsulated DPNN with integrated photonic chips, repeatably enhancing the performance from in-silico BP for different network structures and datasets.
- 3 March 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Open AccessAsymmetrical estimator for training encapsulated deep photonic neural networks
Photonic neural networks (PNNs) are fast in-propagation and high bandwidth paradigms that aim to popularize reproducible NN acceleration with higher efficiency and lower cost. However, the training of PNN is known to be challenging, where the device-to-device and system-to-system variations create imperfect knowledge of the PNN. Despite backpropagation (BP)-based training algorithms being the industry standard for their robustness, generality, and fast gradient convergence for digital training, existing PNN-BP methods rely heavily on accurate intermediate state extraction or extensive computational resources for deep PNNs (DPNNs). The truncated photonic signal propagation and the computation overhead bottleneck DPNN’s operation efficiency and increase system construction cost. Here, we introduce the asymmetrical training (AsyT) method, tailored for encapsulated DPNNs, where the signal is preserved in the analogue photonic domain for the entire structure. AsyT offers a lightweight solution for DPNNs with minimum readouts, fast and energy-efficient operation, and minimum system footprint. AsyT’s ease of operation, error tolerance, and generality aim to promote PNN acceleration in a widened operational scenario despite the fabrication variations and imperfect controls. We demonstrated AsyT for encapsulated DPNN with integrated photonic chips, repeatably enhancing the performance from in-silico BP for different network structures and datasets.
- Top Cited PapersOpen Access
- 27 November 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-11
Chip-scale sensor for spectroscopic metrology
Miniaturized spectrometers hold great promise for in situ, in vitro, and even in vivo sensing applications. However, their size reduction imposes vital performance constraints in meeting the rigorous demands of spectroscopy, including fine resolution, high accuracy, and ultra-wide observation window. The prevailing view in the community holds that miniaturized spectrometers are most suitable for coarse identification of signature peaks. Here, we present an integrated reconstructive spectrometer that enables near-infrared (NIR) spectroscopic metrology, and demonstrate a fully packaged sensor with auxiliary electronics. Such a sensor operates over a 520 nm bandwidth together with a resolution below 8 pm, yielding a record-breaking bandwidth-to-resolution ratio of over 65,000. The classification of different types of solid substances and the concentration measurement of aqueous and organic solutions are performed, all achieving approximately 100% accuracy. Notably, the detection limit of our sensor matches that of commercial benchtop counterparts, which is as low as 0.1% (i.e. 100 mg/dL) for identifying the concentration of glucose solution.
- 27 November 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-11
Top Cited PapersOpen AccessChip-scale sensor for spectroscopic metrology
Miniaturized spectrometers hold great promise for in situ, in vitro, and even in vivo sensing applications. However, their size reduction imposes vital performance constraints in meeting the rigorous demands of spectroscopy, including fine resolution, high accuracy, and ultra-wide observation window. The prevailing view in the community holds that miniaturized spectrometers are most suitable for coarse identification of signature peaks. Here, we present an integrated reconstructive spectrometer that enables near-infrared (NIR) spectroscopic metrology, and demonstrate a fully packaged sensor with auxiliary electronics. Such a sensor operates over a 520 nm bandwidth together with a resolution below 8 pm, yielding a record-breaking bandwidth-to-resolution ratio of over 65,000. The classification of different types of solid substances and the concentration measurement of aqueous and organic solutions are performed, all achieving approximately 100% accuracy. Notably, the detection limit of our sensor matches that of commercial benchtop counterparts, which is as low as 0.1% (i.e. 100 mg/dL) for identifying the concentration of glucose solution.
- Open Access
- 15 August 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (9) , 3730-3740
Benchmarking Reconstructive Spectrometer with Multiresonant Cavities
Recent years have seen the rapid development of miniaturized reconstructive spectrometers (RSs), yet they still confront a range of technical challenges, such as bandwidth/resolution ratio, sensing speed, and/or power efficiency. Reported RS designs often suffer from insufficient decorrelation between sampling channels, which, in essence, is due to inadequate engineering of sampling responses. This in turn results in poor spectral-pixel-to-channel ratios (SPCRs), typically restricted at single digits. So far, there lacks a general guideline for manipulating RS sampling responses for the effectiveness of spectral information acquisition. In this study, we shed light on a fundamental parameter from the compressive sensing (CS) theory-the average mutual correlation coefficient ν-and provide insight into how it serves as a critical benchmark in RS design. To this end, we propose a novel RS design with multiresonant cavities, consisting of a series of partial reflective interfaces. Such multicavity configuration allows the superlative optimization of sampling matrices to achieve minimized ν. Experimentally, we implement a single-shot, dual-band RS on a SiN platform, realizing an overall operation bandwidth of 270 nm and a <0.5 nm resolution with only 15 sampling channels per band. This leads to a record high SPCR of 18.0. Moreover, the proposed multicavity design can be readily adapted to various photonic platforms, ranging from optical fibers to free-space optics. For instance, we showcase that by employing multilayer coatings, an ultrabroadband RS can be optimized to exhibit a 700 nm bandwidth with an SPCR of over 100.
- 15 August 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (9) , 3730-3740
Open AccessBenchmarking Reconstructive Spectrometer with Multiresonant Cavities
Recent years have seen the rapid development of miniaturized reconstructive spectrometers (RSs), yet they still confront a range of technical challenges, such as bandwidth/resolution ratio, sensing speed, and/or power efficiency. Reported RS designs often suffer from insufficient decorrelation between sampling channels, which, in essence, is due to inadequate engineering of sampling responses. This in turn results in poor spectral-pixel-to-channel ratios (SPCRs), typically restricted at single digits. So far, there lacks a general guideline for manipulating RS sampling responses for the effectiveness of spectral information acquisition. In this study, we shed light on a fundamental parameter from the compressive sensing (CS) theory-the average mutual correlation coefficient ν-and provide insight into how it serves as a critical benchmark in RS design. To this end, we propose a novel RS design with multiresonant cavities, consisting of a series of partial reflective interfaces. Such multicavity configuration allows the superlative optimization of sampling matrices to achieve minimized ν. Experimentally, we implement a single-shot, dual-band RS on a SiN platform, realizing an overall operation bandwidth of 270 nm and a <0.5 nm resolution with only 15 sampling channels per band. This leads to a record high SPCR of 18.0. Moreover, the proposed multicavity design can be readily adapted to various photonic platforms, ranging from optical fibers to free-space optics. For instance, we showcase that by employing multilayer coatings, an ultrabroadband RS can be optimized to exhibit a 700 nm bandwidth with an SPCR of over 100.
- 28 April 2000
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 87 (9) , 4727-4729
Domain wall trapping in controlled submicron ferromagnetic elements
The domain configuration in permalloy wires (30 nm thick, 10 μm wide, and 205 μm long) with a wide size range of a narrow central bridge (5 μm long and w μm wide; were investigated in both their demagnetized and remanent states using magnetic force microscopy and the results were confirmed by micromagnetic calculations. At the bridge region, domain walls were found to be shifted by a small external field. Scanning magneto-optical Kerr effect revealed that the coercivity in these structures are the same as that in a straight wire, suggesting that domain wall movement is the dominant process in the magnetization reversal of these structures.- 28 April 2000
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 87 (9) , 4727-4729
Domain wall trapping in controlled submicron ferromagnetic elements
The domain configuration in permalloy wires (30 nm thick, 10 μm wide, and 205 μm long) with a wide size range of a narrow central bridge (5 μm long and w μm wide; were investigated in both their demagnetized and remanent states using magnetic force microscopy and the results were confirmed by micromagnetic calculations. At the bridge region, domain walls were found to be shifted by a small external field. Scanning magneto-optical Kerr effect revealed that the coercivity in these structures are the same as that in a straight wire, suggesting that domain wall movement is the dominant process in the magnetization reversal of these structures.