Wanxin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wanxin Chen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Bi Zhang
State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
6 shared publications - Xingang Zhao
Chinese Academy of Sciences
6 shared publications - Lianqing Liu
Chinese Academy of Sciences
4 shared publications - Xiaowei Tan
Shenyang Institute of Automation, State Key Laboratory of Robotics and Intelligent Systems, Chinese Academy of Sciences, Shenyang, China
3 shared publications - Jiwei Li
Chinese Academy of Sciences
2 shared publications Yiwen Zhao
State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
2 shared publications
Latest Publications
- 3 May 2026
- Published by SAGE Publications in The International Journal of Robotics Research
K2MUSE: A human lower-limb multimodal walking dataset spanning task and acquisition variability for rehabilitation robotics
The natural interaction and control performance of lower limb rehabilitation robots are closely linked to biomechanical information from various human locomotion activities. Multidimensional human motion data significantly deepen the understanding of the complex mechanisms governing neuromuscular alterations, thereby facilitating the development and application of rehabilitation robots in multifaceted real-world environments. However, existing lower limb datasets are inadequate for supplying the essential multimodal data and large-scale gait samples necessary for the development of effective data-driven approaches, and the significant effects of acquisition interference in real applications are neglected. To fill this gap, we present the K2MUSE dataset, which includes a comprehensive collection of multimodal data, comprising kinematic, kinetic, amplitude mode ultrasound (AUS), and surface electromyography (sEMG) measurements. The proposed dataset includes lower limb multimodal data collected from two cohorts, including 30 able-bodied young adults and 12 older adults, across different inclines (0°, ±5°, and ±10°), speeds (0.5 m/s, 1.0 m/s, and 1.5 m/s), and representative non-ideal acquisition conditions (muscle fatigue, electrode shifts, and interday differences). The kinematic and ground reaction force data were collected with a Vicon motion capture system and an instrumented treadmill with embedded force plates, whereas the sEMG and AUS data of 13 muscles on the bilateral lower limbs were synchronously recorded. To validate the quality of the data, we quantified repeatability across locomotion modes, speeds, and inclines, examined physiological signatures under non-ideal acquisition conditions, and observed high agreement with existing public datasets. We also report baseline motion-intention recognition results, including joint angle estimation and gait phase classification, with a multimodal transformer model demonstrating accurate and stable performance. In addition, we present a control-oriented application in which an end-to-end model trained on the K2MUSE dataset provides hip assistance via a soft exoskeleton and yields consistent reductions in metabolic cost across multiple terrains. K2MUSE is released with the corresponding structured documentation, preprocessing pipelines, and example code, thereby providing a comprehensive resource for rehabilitation robot development, biomechanical analysis, and wearable sensing research. The dataset is available at https://k2muse.github.io/ .
- 3 May 2026
- Published by SAGE Publications in The International Journal of Robotics Research
K2MUSE: A human lower-limb multimodal walking dataset spanning task and acquisition variability for rehabilitation robotics
The natural interaction and control performance of lower limb rehabilitation robots are closely linked to biomechanical information from various human locomotion activities. Multidimensional human motion data significantly deepen the understanding of the complex mechanisms governing neuromuscular alterations, thereby facilitating the development and application of rehabilitation robots in multifaceted real-world environments. However, existing lower limb datasets are inadequate for supplying the essential multimodal data and large-scale gait samples necessary for the development of effective data-driven approaches, and the significant effects of acquisition interference in real applications are neglected. To fill this gap, we present the K2MUSE dataset, which includes a comprehensive collection of multimodal data, comprising kinematic, kinetic, amplitude mode ultrasound (AUS), and surface electromyography (sEMG) measurements. The proposed dataset includes lower limb multimodal data collected from two cohorts, including 30 able-bodied young adults and 12 older adults, across different inclines (0°, ±5°, and ±10°), speeds (0.5 m/s, 1.0 m/s, and 1.5 m/s), and representative non-ideal acquisition conditions (muscle fatigue, electrode shifts, and interday differences). The kinematic and ground reaction force data were collected with a Vicon motion capture system and an instrumented treadmill with embedded force plates, whereas the sEMG and AUS data of 13 muscles on the bilateral lower limbs were synchronously recorded. To validate the quality of the data, we quantified repeatability across locomotion modes, speeds, and inclines, examined physiological signatures under non-ideal acquisition conditions, and observed high agreement with existing public datasets. We also report baseline motion-intention recognition results, including joint angle estimation and gait phase classification, with a multimodal transformer model demonstrating accurate and stable performance. In addition, we present a control-oriented application in which an end-to-end model trained on the K2MUSE dataset provides hip assistance via a soft exoskeleton and yields consistent reductions in metabolic cost across multiple terrains. K2MUSE is released with the corresponding structured documentation, preprocessing pipelines, and example code, thereby providing a comprehensive resource for rehabilitation robot development, biomechanical analysis, and wearable sensing research. The dataset is available at https://k2muse.github.io/ .
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (5) , 5590-5597
Design, Control, and Evaluation of a Modular Variable Configuration Rehabilitation Robot for Early Physical Therapy
This letter proposes a modular variable configuration rehabilitation robot (MVCRR), aiming to meet the needs of multi-functional, full-cycle rehabilitation. MVCRR integrates a lower-limb training module and a sit-to-stand module, offering 16 actuated degrees of freedom and supporting four rehabilitation postures: supine, sitting, standing, and sit-to-stand transition, while integrating the functions of typical rehabilitation devices. Meanwhile, a split–reassembly mechanism is designed to enable flexible bedside deployment, while compact scissor mechanisms and optimized actuation design improve adaptability and efficiency. In addition, a distributed bilateral coordination control architecture is established, and a unified human–robot interaction control framework is developed based on a multi-posture dynamic model library, enabling compliant, assist-as-needed control. Eight active and passive training modes are designed, covering gait reconstruction, muscle strengthening, posture transitions, and bilateral coordination. Experimental results demonstrate high-accuracy joint tracking (RMSE$ \leq $ 0.0083 rad) and torque regulation (RMSE$ \leq $ 1.6848 Nm), and good natural-gait reproduction (joint-angle RMSE$ \leq $ 0.094 rad, r$ \geq $ 0.897), validating the effectiveness of rehabilitation training across multiple postures. Overall, MVCRR establishes a systematic and intelligent integrated solution that supports multi-posture training and bedside deployment, demonstrating strong potential for clinical application.- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (5) , 5590-5597
Design, Control, and Evaluation of a Modular Variable Configuration Rehabilitation Robot for Early Physical Therapy
This letter proposes a modular variable configuration rehabilitation robot (MVCRR), aiming to meet the needs of multi-functional, full-cycle rehabilitation. MVCRR integrates a lower-limb training module and a sit-to-stand module, offering 16 actuated degrees of freedom and supporting four rehabilitation postures: supine, sitting, standing, and sit-to-stand transition, while integrating the functions of typical rehabilitation devices. Meanwhile, a split–reassembly mechanism is designed to enable flexible bedside deployment, while compact scissor mechanisms and optimized actuation design improve adaptability and efficiency. In addition, a distributed bilateral coordination control architecture is established, and a unified human–robot interaction control framework is developed based on a multi-posture dynamic model library, enabling compliant, assist-as-needed control. Eight active and passive training modes are designed, covering gait reconstruction, muscle strengthening, posture transitions, and bilateral coordination. Experimental results demonstrate high-accuracy joint tracking (RMSE$ \leq $ 0.0083 rad) and torque regulation (RMSE$ \leq $ 1.6848 Nm), and good natural-gait reproduction (joint-angle RMSE$ \leq $ 0.094 rad, r$ \geq $ 0.897), validating the effectiveness of rehabilitation training across multiple postures. Overall, MVCRR establishes a systematic and intelligent integrated solution that supports multi-posture training and bedside deployment, demonstrating strong potential for clinical application.- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Vol. 55 (10) , 7526-7538
Manifesting Nominal Assistance in Hemiplegia Gait Training Through an Assistive Normality Framework
Rehabilitation exoskeletons have been demonstrated to benefit mobility-limited patients; however, accessibility is hindered by several challenges, and interaction evaluation of coupled human–exoskeleton systems remains critically understudied. In this pioneering study“, assistive normality (AN)” is introduced to characterize the cross-stage spatiotemporal features of exoskeleton-assisted gait in hemiplegic patients, and a multidimensional, low-data-cost metric framework is developed to quantify AN. Three subdivided metrics, including gait restoration (GR), phase-deviation weighting (PDW) and multijoint coordination (MJC), are proposed to assess coupled system interaction behavior across different intervention stages during rehabilitation. A homologous difference evaluation paradigm (HDEP) is introduced to capture pathological differences between healthy and hemiplegic subjects on the basis of the reusability of experimental data, providing an approach for the nominal assistance calibration and assessment of specific exoskeleton devices. In a pilot study with eight healthy individuals and nine hemiplegic patients, between-group metric differences were analyzed to determine the calibrated AN of an exoskeleton. The results provide calibration references for quantitative metrics and demonstrate the ability of framework to characterize the temporal dynamics of human–exoskeleton interactions. The proposed AN framework offers a generalizable approach to assistive robotics, potentially enhancing evaluation of human-robot interaction and advancing clinical rehabilitation applications.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Vol. 55 (10) , 7526-7538
Manifesting Nominal Assistance in Hemiplegia Gait Training Through an Assistive Normality Framework
Rehabilitation exoskeletons have been demonstrated to benefit mobility-limited patients; however, accessibility is hindered by several challenges, and interaction evaluation of coupled human–exoskeleton systems remains critically understudied. In this pioneering study“, assistive normality (AN)” is introduced to characterize the cross-stage spatiotemporal features of exoskeleton-assisted gait in hemiplegic patients, and a multidimensional, low-data-cost metric framework is developed to quantify AN. Three subdivided metrics, including gait restoration (GR), phase-deviation weighting (PDW) and multijoint coordination (MJC), are proposed to assess coupled system interaction behavior across different intervention stages during rehabilitation. A homologous difference evaluation paradigm (HDEP) is introduced to capture pathological differences between healthy and hemiplegic subjects on the basis of the reusability of experimental data, providing an approach for the nominal assistance calibration and assessment of specific exoskeleton devices. In a pilot study with eight healthy individuals and nine hemiplegic patients, between-group metric differences were analyzed to determine the calibrated AN of an exoskeleton. The results provide calibration references for quantitative metrics and demonstrate the ability of framework to characterize the temporal dynamics of human–exoskeleton interactions. The proposed AN framework offers a generalizable approach to assistive robotics, potentially enhancing evaluation of human-robot interaction and advancing clinical rehabilitation applications.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 269-288
Hip–Knee–Ankle Rehabilitation Exoskeleton With Compliant Actuators: From Human–Robot Interaction Control to Clinical Evaluation
While rehabilitation exoskeletons have been extensively studied, systematic design principles for effectively addressing heterogeneous bilateral locomotion in hemiplegia patients are poorly understood. In this article, a multijoint lower exoskeleton driven by series elastic actuators (SEAs) is developed, and the design philosophy of rehabilitation robots for hemiplegia patients is systematically explored. The exoskeleton has six powered joints for both lower limbs in a hip–knee–ankle configuration, and each joint incorporates a custom, lightweight SEA module. A unified interaction-oriented control framework is designed for exoskeleton-assisted walking, including gait generation, task scheduling, and advanced joint-level control. The closed-loop design provides methodical solutions to address hemiplegia rehabilitation needs and provides walking assistance for bilateral lower limbs. Moreover, a multitemplate gait generation approach is proposed to address the altered kinematics induced by exoskeleton-assisted walking and enhance the exoskeleton's adaptability to patient-specific kinematic variations in an iterative manner. Experiments are conducted with both healthy individuals and hemiplegia patients to verify the effectiveness of the exoskeleton system. The clinical outcomes demonstrate that the exoskeleton can achieve mechanical transparency, facilitate movement, and enable coordinated interjoint locomotion for bilateral gait assistance.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 269-288
Hip–Knee–Ankle Rehabilitation Exoskeleton With Compliant Actuators: From Human–Robot Interaction Control to Clinical Evaluation
While rehabilitation exoskeletons have been extensively studied, systematic design principles for effectively addressing heterogeneous bilateral locomotion in hemiplegia patients are poorly understood. In this article, a multijoint lower exoskeleton driven by series elastic actuators (SEAs) is developed, and the design philosophy of rehabilitation robots for hemiplegia patients is systematically explored. The exoskeleton has six powered joints for both lower limbs in a hip–knee–ankle configuration, and each joint incorporates a custom, lightweight SEA module. A unified interaction-oriented control framework is designed for exoskeleton-assisted walking, including gait generation, task scheduling, and advanced joint-level control. The closed-loop design provides methodical solutions to address hemiplegia rehabilitation needs and provides walking assistance for bilateral lower limbs. Moreover, a multitemplate gait generation approach is proposed to address the altered kinematics induced by exoskeleton-assisted walking and enhance the exoskeleton's adaptability to patient-specific kinematic variations in an iterative manner. Experiments are conducted with both healthy individuals and hemiplegia patients to verify the effectiveness of the exoskeleton system. The clinical outcomes demonstrate that the exoskeleton can achieve mechanical transparency, facilitate movement, and enable coordinated interjoint locomotion for bilateral gait assistance.
- Open Access
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 3104-3115
Improving Hand Gesture Recognition Robustness to Dynamic Posture Variations by Multimodal Deep Feature Fusion
Surface electromyography (sEMG), a human-machine interface for gesture recognition, has shown promising potential for decoding motor intentions, but a variety of nonideal factors restrict its practical application in assistive robots. In this paper, we summarized the current mainstream gesture recognition strategies and proposed a gesture recognition method based onmultimodal canonical correlation analysis feature fusion classification (MCAFC) for a nonideal condition that occurs in daily life, i.e., posture variations. The deep features of the sEMG and acceleration signals were first extracted via convolutional neural networks. A canonical correlation analysis was subsequently performed to associate the deep features of the two modalities. The transformed features were utilized as inputs to a linear discriminant analysis classifier to recognize the corresponding gestures. Both offline and real-time experiments were conducted on eight able-bodied subjects. The experimental results indicated that MCAFC achieved an average classification accuracy, average motion completion rate, and average motion completion time of 93.44%, 94.05%, and 1.38 s, respectively, with multiple dynamic postures, indicating significantly better performance than that of comparable methods. The results demonstrate the feasibility and superiority of the proposed multimodal signal feature fusion method for gesture recognition with posture variations, providing a new scheme for myoelectric control.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 3104-3115
Open AccessImproving Hand Gesture Recognition Robustness to Dynamic Posture Variations by Multimodal Deep Feature Fusion
Surface electromyography (sEMG), a human-machine interface for gesture recognition, has shown promising potential for decoding motor intentions, but a variety of nonideal factors restrict its practical application in assistive robots. In this paper, we summarized the current mainstream gesture recognition strategies and proposed a gesture recognition method based onmultimodal canonical correlation analysis feature fusion classification (MCAFC) for a nonideal condition that occurs in daily life, i.e., posture variations. The deep features of the sEMG and acceleration signals were first extracted via convolutional neural networks. A canonical correlation analysis was subsequently performed to associate the deep features of the two modalities. The transformed features were utilized as inputs to a linear discriminant analysis classifier to recognize the corresponding gestures. Both offline and real-time experiments were conducted on eight able-bodied subjects. The experimental results indicated that MCAFC achieved an average classification accuracy, average motion completion rate, and average motion completion time of 93.44%, 94.05%, and 1.38 s, respectively, with multiple dynamic postures, indicating significantly better performance than that of comparable methods. The results demonstrate the feasibility and superiority of the proposed multimodal signal feature fusion method for gesture recognition with posture variations, providing a new scheme for myoelectric control.