MOMattia Orlandi

Mattia Orlandi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mattia Orlandi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EMG Acquisition and Processing for Hand Movement Decoding on Embedded Systems: State of the Art and Challenges

    by Simone Benatti, Elisa Donati, Ali Moin, Marcello Zanghieri, Mattia Orlandi, Alessio Burrello, Fiorenzo Artoni, Silvestro Micera, Luca Benini, Jan M. Rabaey

    The electromyography (EMG) signal is particularly useful in monitoring muscle activity, and it can be acquired noninvasively on the skin surface. Thanks to these key characteristics, EMG-based human–machine interfaces (HMIs) for prosthetic myocontrol, as well as gesture recognition, are becoming widespread. A key challenge in this context is to design embedded systems to process EMG signals and generate motor commands with miniaturized, unobtrusive, and low-power devices, reliably and in real time, at a relatively low cost to provide continuous monitoring without causing stigma or discomfort. This article presents an in-depth review of the current status and future research challenges in systems and circuits for EMG acquisition and processing. We start by illustrating the sensor interfaces and acquisition systems required for signal analysis to provide efficient and effective ways of understanding the signal and its nature. We, then, focus on conventional state-of-the-art (SoA) EMG gesture recognition algorithms as well as novel architectures that tackle EMG processing challenges, i.e., hyperdimensional computing (HDC), blind source separation (BSS), and spiking neural networks (SNNs). Finally, we discuss open challenges, such as EMG variability, natural control, and efficient computation, to bring the myocontrol completely out of the laboratory, filling the gap between research prototypes and real-world applications.


  • Maestro: A 302 GFLOPS/W and 19.8GFLOPS RISC-V Vector-Tensor Architecture for Wearable Ultrasound Edge Computing

    by Mattia Sinigaglia, Amirhossein Kiamarzi, Marco Bertuletti, Luigi Ghionda, Mattia Orlandi, Riccardo Tedeschi, Aurora Di Giampietro, Yvan Tortorella, Luca Bertaccini, Simone Benatti, et al.

    Most Wearable Ultrasound (WUS) devices lack the computational power to process signals at the edge, instead relying on remote offload, which introduces latency, high power consumption, and privacy concerns. We present Maestro, a RISC-V SoC with unified Vector-Tensor Unit (VTU) and memory-coupled Fast Fourier Transform (FFT) accelerators targeting edge processing for wearable ultrasound devices, fabricated using low-cost TSMC 65nm CMOS technology. The VTU achieves peak 302GFLOPS/W and 19.8GFLOPS at FP16, while the multi-precision 16/32-bit floating-point FFT accelerator delivers peak 60.6GFLOPS/W and 3.6GFLOPS at FP16. We evaluate Maestro on a US-based gesture recognition task, achieving 1.62GFLOPS in signal processing at 26.68GFLOPS/W, and 19.52GFLOPS in Convolutional Neural Network (CNN) workloads at 298.03GFLOPS/W. Compared to a state-of-the-art SoC with a similar mission profile, Maestro achieves a $5\times $ speedup while consuming only 12mW, with an energy consumption of 2.5mJ in a wearable US channel preprocessing and ML-based postprocessing pipeline.


  • sEMG-Driven Hand Dynamics Estimation With Incremental Online Learning on a Parallel Ultra-Low-Power Microcontroller

    by Marcello Zanghieri, Pierangelo Maria Rapa, Mattia Orlandi, Elisa Donati, Luca Benini, Simone Benatti

    Surface electromyography (sEMG) is a State-of-the-Art (SoA) sensing modality for non-invasive human-machine interfaces for consumer, industrial, and rehabilitation use cases. The main limitation of the current sEMG-driven control policies is the sEMG’s inherent variability, especially cross-session due to sensor repositioning; this limits the generalization of the Machine/Deep Learning (ML/DL) in charge of the signal-to-command mapping. The other hot front on the ML/DL side of sEMG-driven control is the shift from the classification of fixed hand positions to the regression of hand kinematics and dynamics, promising a more versatile and fluid control. We present an incremental online-training strategy for sEMG-based estimation of simultaneous multi-finger forces, using a small Temporal Convolutional Network suitable for embedded learning-on-device. We validate our method on the HYSER dataset, cross-day. Our incremental online training reaches a cross-day Mean Absolute Error (MAE) of (9.58 ± 3.89)% of the Maximum Voluntary Contraction on HYSER’s RANDOM dataset of improvised, non-predefined force sequences, which is the most challenging and closest to real scenarios. This MAE is on par with an accuracy-oriented, non-embeddable offline training exploiting more epochs. Further, we demonstrate that our online training approach can be deployed on the GAP9 ultra-low power microcontroller, obtaining a latency of 1.49 ms and an energy draw of just 40.4 uJ per forward-backward-update step. These results show that our solution fits the requirements for accurate and real-time incremental training-on-device.


  • Real-Time Motor Unit Tracking From sEMG Signals With Adaptive ICA on a Parallel Ultra-Low Power Processor

    by Mattia Orlandi, Pierangelo Maria Rapa, Marcello Zanghieri, Sebastian Frey, Victor Kartsch, Luca Benini, Simone Benatti

    Spike extraction by blind source separation (BSS) algorithms can successfully extract physiologically meaningful information from the sEMG signal, as they are able to identify motor unit (MU) discharges involved in muscle contractions. However, BSS approaches are currently restricted to isometric contractions, limiting their applicability in real-world scenarios. We present a strategy to track MUs across different dynamic hand gestures using adaptive independent component analysis (ICA): first, a pool of MUs is identified during isometric contractions, and the decomposition parameters are stored; during dynamic gestures, the decomposition parameters are updated online in an unsupervised fashion, yielding the refined MUs; then, a Pan-Tompkins-inspired algorithm detects the spikes in each MUs; finally, the identified spikes are fed to a classifier to recognize the gesture. We validate our approach on a 4-subject, 7-gesture + rest dataset collected with our custom 16-channel dry sEMG armband, achieving an average balanced accuracy of 85.58±14.91% and macro-F1 score of 85.86±14.48%. We deploy our solution onto GAP9, a parallel ultra-low-power microcontroller specialized for computation-intensive linear algebra applications at the edge, obtaining an energy consumption of 4.72 mJ @ 240 MHz and a latency of 121.3 ms for each 200 ms-long window of sEMG signal.


  • Event-Based Estimation of Hand Forces From High-Density Surface EMG on a Parallel Ultralow-Power Microcontroller

    by Marcello Zanghieri, Pierangelo Maria Rapa, Mattia Orlandi, Elisa Donati, Luca Benini, Simone Benatti

    Modeling hand kinematics and dynamics is a key goal for research on Human-Machine Interfaces, with surface electromyography (sEMG) being the most commonly used sensing modality. Though under-researched, sEMG regression-based modeling of hand movements and forces is promising for finer control than allowed by mapping to fixed gestures. We present an event-based sEMG encoding for multi-finger force estimation implemented on a microcontroller unit (MCU). We are the first to target the HYSER High-Density (HD)-sEMG dataset in multi-day conditions closest to a real scenario without a fixed force pattern. Our Mean Absolute Error of (8.4 ± 2.8)% of the Maximum Voluntary Contraction (MVC) is on par with State-of-the-Art (SoA) works on easier settings such as within-day, single-finger, or fixed-exercise. We deploy our solution for HYSER’s hardest task on a parallel ultra-low power MCU, getting an energy consumption below 6.5 uJ per sample, 2.8× to 11× more energy-efficient than SoA single-core solutions, and a latency below 280 us per sample, shorter than HYSER’s HD-sEMG sampling period, thus compatible with real-time operation on embedded devices.