Patrick See
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patrick See has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chong Chen
Cavendish Laboratory, University of Cambridge 1 , JJ Thomson Avenue, Cambridge CB3 0US
2 shared publications - David. A. Ritchie
University of Cambridge
2 shared publications - Ivan Rungger
National Physical Laboratory
2 shared publications - Jonathan P. Griffiths
University of Cambridge
2 shared publications - Masaya Kataoka
National Physical Laboratory
2 shared publications - N. Schoinas
National Physical Laboratory 1 , Teddington TW11 0LW, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (10)
Hydrogen passivation effects on spatially resolved charge trap densities in Si(100)–SiO2
As silicon-based devices continue to shrink to the nanoscale, traps at the Si–SiO2 interface pose increasing challenges to device performance. These traps reduce channel carrier mobility and shift threshold voltages in integrated circuits and introduce charge noise in quantum systems, reducing their coherence times. Knowledge of the precise location of such traps aids in understanding their influence on device performance. In this work, we demonstrate that frequency-modulated atomic force microscopy allows the detection of individual traps. We use this to study how sample preparation, specifically the introduction of a buried hydrogen termination layer and post-processing annealing in forming gas (N2 + H2), affects the density of donor-like traps in Si(100)–SiO2 systems. We spatially map and quantify traps in both conventionally prepared (“pristine”) silicon samples and those processed under ultrahigh vacuum for hydrogen resist lithography (HRL). We confirm previous studies demonstrating hydrogen passivation of traps and find that hydrogen termination further reduces the donor-like trap density. We also observe a significant reduction in two-level donor-like traps in the hydrogen-terminated samples compared to pristine silicon samples. These findings suggest that HRL-prepared silicon may offer advantages for high-performance nanoscale and atomic-scale devices due to reduced trap densities.
- 1 October 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (10)
Open AccessHydrogen passivation effects on spatially resolved charge trap densities in Si(100)–SiO2
As silicon-based devices continue to shrink to the nanoscale, traps at the Si–SiO2 interface pose increasing challenges to device performance. These traps reduce channel carrier mobility and shift threshold voltages in integrated circuits and introduce charge noise in quantum systems, reducing their coherence times. Knowledge of the precise location of such traps aids in understanding their influence on device performance. In this work, we demonstrate that frequency-modulated atomic force microscopy allows the detection of individual traps. We use this to study how sample preparation, specifically the introduction of a buried hydrogen termination layer and post-processing annealing in forming gas (N2 + H2), affects the density of donor-like traps in Si(100)–SiO2 systems. We spatially map and quantify traps in both conventionally prepared (“pristine”) silicon samples and those processed under ultrahigh vacuum for hydrogen resist lithography (HRL). We confirm previous studies demonstrating hydrogen passivation of traps and find that hydrogen termination further reduces the donor-like trap density. We also observe a significant reduction in two-level donor-like traps in the hydrogen-terminated samples compared to pristine silicon samples. These findings suggest that HRL-prepared silicon may offer advantages for high-performance nanoscale and atomic-scale devices due to reduced trap densities.
- Open Access
- 16 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (12)
Fast characterization of multiplexed single-electron pumps with machine learning
We present an efficient machine learning based automated framework for the fast tuning of single-electron pump devices into current quantization regimes. It uses a sparse measurement approach based on an iterative active learning algorithm to take targeted measurements in the gate voltage parameter space. When compared to conventional parameter scans, our automated framework allows us to decrease the number of measurement points by about an order of magnitude. This corresponds to an eightfold decrease in the time required to determine quantization errors, which are estimated via an exponential extrapolation of the first current plateau embedded into the algorithm. We show the robustness of the framework by characterizing 28 individual devices arranged in a GaAs/AlGaAs multiplexer array, which we use to identify a subset of devices suitable for parallel operation at communal gate voltages. The method opens up the possibility to efficiently scale the characterization of such multiplexed devices to a large number of pumps.
- 16 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (12)
Open AccessFast characterization of multiplexed single-electron pumps with machine learning
We present an efficient machine learning based automated framework for the fast tuning of single-electron pump devices into current quantization regimes. It uses a sparse measurement approach based on an iterative active learning algorithm to take targeted measurements in the gate voltage parameter space. When compared to conventional parameter scans, our automated framework allows us to decrease the number of measurement points by about an order of magnitude. This corresponds to an eightfold decrease in the time required to determine quantization errors, which are estimated via an exponential extrapolation of the first current plateau embedded into the algorithm. We show the robustness of the framework by characterizing 28 individual devices arranged in a GaAs/AlGaAs multiplexer array, which we use to identify a subset of devices suitable for parallel operation at communal gate voltages. The method opens up the possibility to efficiently scale the characterization of such multiplexed devices to a large number of pumps.
- 9 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (11)
Statistical study and parallelization of multiplexed single-electron sources
Increasing the electric current from a single-electron source is a main challenge in an effort to establish the standard of the ampere defined by the fixed value of the elementary charge e and the operation frequency f. While the current scales with the frequency, due to an operation frequency limit for maintaining accurate single-electron transfer, parallelization of single-electron sources is expected to be a more practical solution to increase the generated electric current I=Nef, where N is the number of parallelized devices. One way to parallelize single-electron sources without increasing the complexity in device operation is to use a common gate. Such a scheme will require each device to have the same operation parameters for single-electron transfer. In order to investigate this possibility, we study the statistics for operation gate voltages using single-electron sources embedded in a multiplexer circuit. The multiplexer circuit allows us to measure 64 single-electron sources individually in a single cooldown. We also demonstrate the parallelization of three single-electron sources and observe the generated current enhanced by a factor of three.
- 9 September 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (11)
Statistical study and parallelization of multiplexed single-electron sources
Increasing the electric current from a single-electron source is a main challenge in an effort to establish the standard of the ampere defined by the fixed value of the elementary charge e and the operation frequency f. While the current scales with the frequency, due to an operation frequency limit for maintaining accurate single-electron transfer, parallelization of single-electron sources is expected to be a more practical solution to increase the generated electric current I=Nef, where N is the number of parallelized devices. One way to parallelize single-electron sources without increasing the complexity in device operation is to use a common gate. Such a scheme will require each device to have the same operation parameters for single-electron transfer. In order to investigate this possibility, we study the statistics for operation gate voltages using single-electron sources embedded in a multiplexer circuit. The multiplexer circuit allows us to measure 64 single-electron sources individually in a single cooldown. We also demonstrate the parallelization of three single-electron sources and observe the generated current enhanced by a factor of three.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Needle in a haystack: Efficiently finding atomically defined quantum dots for electrostatic force microscopy
The ongoing development of single electron, nano-, and atomic scale semiconductor devices would greatly benefit from a characterization tool capable of detecting single electron charging events with high spatial resolution at low temperatures. In this work, we introduce a novel Atomic Force Microscope (AFM) instrument capable of measuring critical device dimensions, surface roughness, electrical surface potential, and ultimately the energy levels of quantum dots and single electron transistors in ultra miniaturized semiconductor devices. The characterization of nanofabricated devices with this type of instrument presents a challenge: finding the device. We, therefore, also present a process to efficiently find a nanometer sized quantum dot buried in a 10 × 10 mm2 silicon sample using a combination of optical positioning, capacitive sensors, and AFM topography in a vacuum.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Needle in a haystack: Efficiently finding atomically defined quantum dots for electrostatic force microscopy
The ongoing development of single electron, nano-, and atomic scale semiconductor devices would greatly benefit from a characterization tool capable of detecting single electron charging events with high spatial resolution at low temperatures. In this work, we introduce a novel Atomic Force Microscope (AFM) instrument capable of measuring critical device dimensions, surface roughness, electrical surface potential, and ultimately the energy levels of quantum dots and single electron transistors in ultra miniaturized semiconductor devices. The characterization of nanofabricated devices with this type of instrument presents a challenge: finding the device. We, therefore, also present a process to efficiently find a nanometer sized quantum dot buried in a 10 × 10 mm2 silicon sample using a combination of optical positioning, capacitive sensors, and AFM topography in a vacuum.