Benjamin Baldwin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Benjamin Baldwin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Allison Li
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California
1 shared publication Charlotte Lin
New Jersey Governor's School of Engineering and Technology
1 shared publication- David S. La Mantia
Georgia Tech Research Institute, Atlanta, GA 30332, USA
1 shared publication - Eric B. Norrgard
National Institute of Standards and Technology
1 shared publication - Harish Devaraj
Rutgers University, New Brunswick, New Jersey 08854, USA
1 shared publication Keith Lehman
New Jersey Governor's School of Engineering and Technology
1 shared publication
Latest Publications
- 23 August 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 110 (2) , 023110
Spectroscopy of laser-cooling transitions in MgF
We measure the complete set of transition frequencies necessary to laser cool and trap MgF molecules. Specifically, we report the frequency of multiple low- transitions of the , , and bands of MgF. The measured spectrum allows the spin-rotation and hyperfine parameters of the state of MgF to be determined. Furthermore, we demonstrate optical cycling in MgF by pumping molecules into the states. Optical pumping enhances the spectroscopic signals of transitions originating in the level of the states.- 23 August 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 110 (2) , 023110
Spectroscopy of laser-cooling transitions in MgF
We measure the complete set of transition frequencies necessary to laser cool and trap MgF molecules. Specifically, we report the frequency of multiple low- transitions of the , , and bands of MgF. The measured spectrum allows the spin-rotation and hyperfine parameters of the state of MgF to be determined. Furthermore, we demonstrate optical cycling in MgF by pumping molecules into the states. Optical pumping enhances the spectroscopic signals of transitions originating in the level of the states.- 11 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Integrating Electronics with Solid Structures Using 3D Circuits
Water safety is a critical issue facing many parts of the world today, but current water quality detection methods are complicated and cumbersome. 3D printing has allowed for the integration of electronics into solid structures, creating new products that promote consumer access to sensor data. A 3D printed water bottle was built to utilize this technology by integrating sensors to test pH, turbidity, and total dissolved solids (TDS) of a liquid, making basic water safety testing accessible for the general public. The bottle was controlled with an Arduino Uno unit and included binary LED indicators to display a relative assessment of water quality. Values were recorded from each sensor by testing various liquids. This product was determined to be accurate in measuring water quality factors when compared to known values, and is an efficient method for users to assess water safety in a compact form.
- 11 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Integrating Electronics with Solid Structures Using 3D Circuits
Water safety is a critical issue facing many parts of the world today, but current water quality detection methods are complicated and cumbersome. 3D printing has allowed for the integration of electronics into solid structures, creating new products that promote consumer access to sensor data. A 3D printed water bottle was built to utilize this technology by integrating sensors to test pH, turbidity, and total dissolved solids (TDS) of a liquid, making basic water safety testing accessible for the general public. The bottle was controlled with an Arduino Uno unit and included binary LED indicators to display a relative assessment of water quality. Values were recorded from each sensor by testing various liquids. This product was determined to be accurate in measuring water quality factors when compared to known values, and is an efficient method for users to assess water safety in a compact form.