Niels Kant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Niels Kant has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Carine J. M. Doggen
Health Technology and Services Research, Techmed Centre, University of Twente, Enschede, The Netherlands
2 shared publications - Mark Vincent Koning
Department of Anesthesiology and Intensive Care, Rijnstate Hospital, Arnhem, The Netherlands
2 shared publications Bart P. L. Witteman
Rijnstate Hospital, Vitalys Obesity Centre, Arnhem, The Netherlands
1 shared publication- Brenda J. Bergink-Voorthuis
Department of Health Technology and Services Research, Technical Medical Centre, University of Twente, Enschede, The Netherlands
1 shared publication - Carlijn A. Vernooij
Department of Patient Care and Monitoring, Philips Research, High Tech Campus 34, 5656 AE Eindhoven, The Netherlands
1 shared publication - Catharina Gerarda Maria Groothuis-Oudshoorn
Department of Health Technology and Services Research, Technical Medical Centre, University of Twente, Enschede, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 22 August 2024
- Published by IOS Press
- Vol. 316, 1744-1745
Continuous Monitoring by a Wearable Sensor Did Not Enhance Discharge Decision-Making in an Acute Admission Ward: Results of a Randomized Controlled Trial
Adding continuous monitoring to usual care at an acute admission ward did not have an effect on the proportion of patients safely discharged. Implementation challenges of continuous monitoring may have contributed to the lack of effect observed.
- 22 August 2024
- Published by IOS Press
- Vol. 316, 1744-1745
Open AccessContinuous Monitoring by a Wearable Sensor Did Not Enhance Discharge Decision-Making in an Acute Admission Ward: Results of a Randomized Controlled Trial
Adding continuous monitoring to usual care at an acute admission ward did not have an effect on the proportion of patients safely discharged. Implementation challenges of continuous monitoring may have contributed to the lack of effect observed.
- Open Access
- 8 December 2021
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (5) , 1449-1459
Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting
Our aim was to determine the agreement of heart rate (HR) and respiratory rate (RR) measurements by the Philips Biosensor with a reference monitor (General Electric Carescape B650) in severely obese patients during and after bariatric surgery. Additionally, sensor reliability was assessed. Ninety-four severely obese patients were monitored with both the Biosensor and reference monitor during and after bariatric surgery. Agreement was defined as the mean absolute difference between both monitoring devices. Bland Altman plots and Clarke Error Grid analysis (CEG) were used to visualise differences. Sensor reliability was reflected by the amount, duration and causes of data loss. The mean absolute difference for HR was 1.26 beats per minute (bpm) (SD 0.84) during surgery and 1.84 bpm (SD 1.22) during recovery, and never exceeded the 8 bpm limit of agreement. The mean absolute difference for RR was 1.78 breaths per minute (brpm) (SD 1.90) during surgery and 4.24 brpm (SD 2.75) during recovery. The Biosensor’s RR measurements exceeded the 2 brpm limit of agreement in 58% of the compared measurements. Averaging 15 min of measurements for both devices improved agreement. CEG showed that 99% of averaged RR measurements resulted in adequate treatment. Data loss was limited to 4.5% of the total duration of measurements for RR. No clear causes for data loss were found. The Biosensor is suitable for remote monitoring of HR, but not RR in morbidly obese patients. Future research should focus on improving RR measurements, the interpretation of continuous data, and development of smart alarm systems.
- 8 December 2021
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (5) , 1449-1459
Open AccessContinuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting
Our aim was to determine the agreement of heart rate (HR) and respiratory rate (RR) measurements by the Philips Biosensor with a reference monitor (General Electric Carescape B650) in severely obese patients during and after bariatric surgery. Additionally, sensor reliability was assessed. Ninety-four severely obese patients were monitored with both the Biosensor and reference monitor during and after bariatric surgery. Agreement was defined as the mean absolute difference between both monitoring devices. Bland Altman plots and Clarke Error Grid analysis (CEG) were used to visualise differences. Sensor reliability was reflected by the amount, duration and causes of data loss. The mean absolute difference for HR was 1.26 beats per minute (bpm) (SD 0.84) during surgery and 1.84 bpm (SD 1.22) during recovery, and never exceeded the 8 bpm limit of agreement. The mean absolute difference for RR was 1.78 breaths per minute (brpm) (SD 1.90) during surgery and 4.24 brpm (SD 2.75) during recovery. The Biosensor’s RR measurements exceeded the 2 brpm limit of agreement in 58% of the compared measurements. Averaging 15 min of measurements for both devices improved agreement. CEG showed that 99% of averaged RR measurements resulted in adequate treatment. Data loss was limited to 4.5% of the total duration of measurements for RR. No clear causes for data loss were found. The Biosensor is suitable for remote monitoring of HR, but not RR in morbidly obese patients. Future research should focus on improving RR measurements, the interpretation of continuous data, and development of smart alarm systems.