Zhijun Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhijun Yin has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dongbai Xue
Tongji University
2 shared publications Guangxu Xiao
Tongji Univ, Natl Metrol & Testing Ctr Integrated Circuit Measu, Shanghai 200092, Peoples R China
2 shared publicationsJunyu Shen
Tongji Univ, Natl Metrol & Testing Ctr Integrated Circuit Measu, Shanghai 200092, Peoples R China
2 shared publications- Xiao Deng
Tongji University
2 shared publications - Xinbin Cheng
Tongji University
2 shared publications - Xiong Dun
Institute of Precision Optical Engineering, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
2 shared publications
Latest Publications
- 23 December 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 015048
Comparison measurements of natural constants based on laser-focused atomic deposition and extreme ultraviolet interference lithography
Traceability is the foundation of accuracy and consistency in dimensional metrology. Meter in the International System of Units is defined and reproduced by natural constants. Comparing the differences in traceability approaches based on different natural constants can better understand the real size of manufacturing structures. This paper compares the consistency of three traceability approaches based on chromium atomic transition wavelength, iodine-stabilized laser wavelength (top-down approach), and silicon lattice spacing (bottom-up approach) in nanoscale dimensional metrology. For comparison, the measured objects are silicon gratings manufactured by laser-focused atomic deposition (LFAD) and extreme ultraviolet interference lithography (EUV IL). Notably, the pitch of the silicon gratings can be traced from the transition wavelength of chromium (7S3→ 7P4, λ = 425.5533 nm). For silicon gratings manufactured by LFAD and EUV IL at diffraction order m = 1, the expected pitch of the silicon grating is λ 4 . The pitch of the silicon grating is measured using a top-down (metrological atomic force microscope) approach, and the deviation between the measured result and the pitch based on the transition wavelength of chromium is 0.1 nm. For silicon gratings manufactured by LFAD and EUV IL at diffraction order m = 2, the expected pitch of the silicon grating is λ 8 . This silicon grating is measured using a bottom-up approach, and the deviation between the measured results and the pitch based on the transition wavelength of chromium is 0.2 nm. This study provides a feasible solution for integrating various measurement methods and different traceability approaches at the nanoscale. It demonstrates the potential and feasibility of a nanoscale dimensional metrology traceability chain based on self-traceable gratings.
- 23 December 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 015048
Comparison measurements of natural constants based on laser-focused atomic deposition and extreme ultraviolet interference lithography
Traceability is the foundation of accuracy and consistency in dimensional metrology. Meter in the International System of Units is defined and reproduced by natural constants. Comparing the differences in traceability approaches based on different natural constants can better understand the real size of manufacturing structures. This paper compares the consistency of three traceability approaches based on chromium atomic transition wavelength, iodine-stabilized laser wavelength (top-down approach), and silicon lattice spacing (bottom-up approach) in nanoscale dimensional metrology. For comparison, the measured objects are silicon gratings manufactured by laser-focused atomic deposition (LFAD) and extreme ultraviolet interference lithography (EUV IL). Notably, the pitch of the silicon gratings can be traced from the transition wavelength of chromium (7S3→ 7P4, λ = 425.5533 nm). For silicon gratings manufactured by LFAD and EUV IL at diffraction order m = 1, the expected pitch of the silicon grating is λ 4 . The pitch of the silicon grating is measured using a top-down (metrological atomic force microscope) approach, and the deviation between the measured result and the pitch based on the transition wavelength of chromium is 0.1 nm. For silicon gratings manufactured by LFAD and EUV IL at diffraction order m = 2, the expected pitch of the silicon grating is λ 8 . This silicon grating is measured using a bottom-up approach, and the deviation between the measured results and the pitch based on the transition wavelength of chromium is 0.2 nm. This study provides a feasible solution for integrating various measurement methods and different traceability approaches at the nanoscale. It demonstrates the potential and feasibility of a nanoscale dimensional metrology traceability chain based on self-traceable gratings.
- Open Access
- 10 September 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (12) , 125009
Shortened and simplified traceability chain for dimensional metrology based on self-traceable standards
Nanoscale measurement is an essential task of nanomanufacturing, and measurement traceability is a fundamental aspect of nanoscale measurement. High-precision nanoscale measurement instruments (e.g. atomic force microscopes (AFM) and scanning electron microscopes (SEM)) need to be calibrated by traceable standards to ensure their accuracy and reliability. However, due to the suboptimal accuracy, uniformity, and consistency of existing standards, they need to be calibrated by metrological instruments traceable to primary length standards (e.g. physical wavelength standards) before use. This results in a long traceability chain that leads to error accumulation and significantly reduces calibration efficiency. This paper proposes a novel shortened and simplified traceability chain, where the physical wavelength standard corresponding to the 7S3 → 7P4° transition frequency of chromium atoms is materialized into self-traceable gratings using the atom lithography technology. The self-traceable gratings can then be directly applied for calibrating measurement instruments. To verify this approach, the self-traceable gratings are calibrated using a metrological AFM of the Physikalisch-Technische Bundesanstalt. Measurement results confirmed the feasibility of the approach. Particularly, our results show that the self-traceable gratings have excellent uniformity over different measurement areas and consistency over different samples, both at 0.001 nm level. Finally, the application of the self-traceable gratings for the calibrations of a commercial AFM and SEM is demonstrated. The new traceability chain significantly simplifies the calibration process, providing a more reliable and higher efficient calibration approach for advanced nanomanufacturing than that of the state-of-the-art.
- 10 September 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (12) , 125009
Open AccessShortened and simplified traceability chain for dimensional metrology based on self-traceable standards
Nanoscale measurement is an essential task of nanomanufacturing, and measurement traceability is a fundamental aspect of nanoscale measurement. High-precision nanoscale measurement instruments (e.g. atomic force microscopes (AFM) and scanning electron microscopes (SEM)) need to be calibrated by traceable standards to ensure their accuracy and reliability. However, due to the suboptimal accuracy, uniformity, and consistency of existing standards, they need to be calibrated by metrological instruments traceable to primary length standards (e.g. physical wavelength standards) before use. This results in a long traceability chain that leads to error accumulation and significantly reduces calibration efficiency. This paper proposes a novel shortened and simplified traceability chain, where the physical wavelength standard corresponding to the 7S3 → 7P4° transition frequency of chromium atoms is materialized into self-traceable gratings using the atom lithography technology. The self-traceable gratings can then be directly applied for calibrating measurement instruments. To verify this approach, the self-traceable gratings are calibrated using a metrological AFM of the Physikalisch-Technische Bundesanstalt. Measurement results confirmed the feasibility of the approach. Particularly, our results show that the self-traceable gratings have excellent uniformity over different measurement areas and consistency over different samples, both at 0.001 nm level. Finally, the application of the self-traceable gratings for the calibrations of a commercial AFM and SEM is demonstrated. The new traceability chain significantly simplifies the calibration process, providing a more reliable and higher efficient calibration approach for advanced nanomanufacturing than that of the state-of-the-art.