Bing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bing Chen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Xiaonan Yang
Zhengzhou University
2 shared publications Congyan Lu
State Key Laboratory of Fabrication Technologies for Integrated Circuits, Institute of Microelectronics, Chinese Academy of Sciences, Beijing, China
1 shared publication- Feng Zhang
Key Laboratory of Microelectronics Devices and Integrated Technology, Institute of Microelectronics, Chinese Academy of Sciences, Beijing, China
1 shared publication - Guan Yang
School of Electrical and Information Engineering, National Center for International Joint Research of Electronic Materials and Systems, International Joint-Laboratory of Electronic Materials and Systems of Henan Province, Institute of Intelligence Sensing, Zhengzhou University, Zhengzhou, China
1 shared publication - Jianquan Yao
Tianjin University
1 shared publication - Jiawei Wang
Institute of Microelectronics, Chinese Academy of Sciences
1 shared publication
Latest Publications
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (5) , 2740-2746
High-Sensitivity InGaZnO FET Sensor Array With Offset Self-Calibration for Multibiomarker Sensing
This work proposes a dual-gate InGaZnO thin-film transistor sensor array for label-free and cross-scale multiple biomarkers detection, including single-stranded deoxyribonucleic acid (ssDNA) and protein CA125. We exploit dual gate modulation for threshold voltage and CMOS-based SAR-assisted digital-to-analog converter (DAC) VBG calibration circuit to eliminate initial VTH offset variation caused by different functionalizations, which improve the reliability of the multibiomarker sensor array. At the same time, receptor enhancement on the indium gallium zinc oxide (IGZO) sensing membrane was detected by fluorescence assay, realizing higher sensitivity for biosensor. We demonstrate the sensor array response for pH in static and real-time mode, realizing near-Nernst limit sensitivity (55.02 mV/pH). Furthermore, at the top-gate configuration, with low operation voltage (0.1 V) and low offset variation (about 2 nA), the IGZO sensor array exhibits great performance for biomarker sensing which achieves sensitivity up to 4.426%/decade for ssDNA and 1102 nA/decade for CA125, with the limit of detection (LoD) of 1.67 aM for ssDNA and 0.1 fg/mL for CA125. This biosensor array provides a potential approach to realize miniaturization and high-density integration of multidimensional-biomarker detection.
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (5) , 2740-2746
High-Sensitivity InGaZnO FET Sensor Array With Offset Self-Calibration for Multibiomarker Sensing
This work proposes a dual-gate InGaZnO thin-film transistor sensor array for label-free and cross-scale multiple biomarkers detection, including single-stranded deoxyribonucleic acid (ssDNA) and protein CA125. We exploit dual gate modulation for threshold voltage and CMOS-based SAR-assisted digital-to-analog converter (DAC) VBG calibration circuit to eliminate initial VTH offset variation caused by different functionalizations, which improve the reliability of the multibiomarker sensor array. At the same time, receptor enhancement on the indium gallium zinc oxide (IGZO) sensing membrane was detected by fluorescence assay, realizing higher sensitivity for biosensor. We demonstrate the sensor array response for pH in static and real-time mode, realizing near-Nernst limit sensitivity (55.02 mV/pH). Furthermore, at the top-gate configuration, with low operation voltage (0.1 V) and low offset variation (about 2 nA), the IGZO sensor array exhibits great performance for biomarker sensing which achieves sensitivity up to 4.426%/decade for ssDNA and 1102 nA/decade for CA125, with the limit of detection (LoD) of 1.67 aM for ssDNA and 0.1 fg/mL for CA125. This biosensor array provides a potential approach to realize miniaturization and high-density integration of multidimensional-biomarker detection.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection
A simple Mach-Zehnder interferometer (MZI) induced by no-core-fiber (NCF) offset microcavity is proposed and demonstrated for temperature self-compensated biosensing. The microcavity is fabricated by on-line fiber cutting-welding method. Benefiting from the directly interact between microfluidics and fiber core signal in microcavity instead of evanescent wave, an ultrahigh RI sensitivity of -12146 nm/RIU was obtained by experiment with temperature cross-sensitivity of 2.05 nm/°C. The influence of microcavity length was analyzed in detail. Temperature self-compensation can be realized by solving a multivariate matrix. Finally, the bovine serum albumin (BSA) samples in different concentrations were detected to evaluate the biosensing capability. Experiments demonstrated that the designed sensor exhibited a BSA concentration sensitivity of -10.4 nm/mg/mL and a detection limit of 1.9 μg/mL, which shows great potential for label-free biochemical trace detections without temperature-induced cross-sensitivity.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Temperature Self-Compensated Biosensor Based on No-Core-Fiber Offset Microcavity for Label-Free BSA Detection
A simple Mach-Zehnder interferometer (MZI) induced by no-core-fiber (NCF) offset microcavity is proposed and demonstrated for temperature self-compensated biosensing. The microcavity is fabricated by on-line fiber cutting-welding method. Benefiting from the directly interact between microfluidics and fiber core signal in microcavity instead of evanescent wave, an ultrahigh RI sensitivity of -12146 nm/RIU was obtained by experiment with temperature cross-sensitivity of 2.05 nm/°C. The influence of microcavity length was analyzed in detail. Temperature self-compensation can be realized by solving a multivariate matrix. Finally, the bovine serum albumin (BSA) samples in different concentrations were detected to evaluate the biosensing capability. Experiments demonstrated that the designed sensor exhibited a BSA concentration sensitivity of -10.4 nm/mg/mL and a detection limit of 1.9 μg/mL, which shows great potential for label-free biochemical trace detections without temperature-induced cross-sensitivity.