Ahmed S. Alharbi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmed S. Alharbi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Abaad A. Alenezi
KSAMC—Maternity and Children Hospital, Madinah 42313, Saudi Arabia
1 shared publication - Amjad M. Alamin
Diagnostic Radiography Department, College of Applied Medical Sciences, Taibah University, Madinah 41477, Saudi Arabia
1 shared publication - Fahad H. Alhazmi
Department of Diagnostic Radiology, College of Applied Medical Sciences, Taibah University, Medina, Saudi Arabia
1 shared publication - Fai H. Hadi
KSAMC—Maternity and Children Hospital, Madinah 42313, Saudi Arabia
1 shared publication - Faisal A. Alrehily
Department of Diagnostic Radiology, College of Applied Medical Sciences, Taibah University, Madinah, Kingdom of Saudi Arabia
1 shared publication - Khalid M. Aloufi
Diagnostic Radiography Department, College of Applied Medical Sciences, Taibah University, Madinah 41477, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 27 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7583
Assessing Effective Doses and Proposing DRLs for Pediatric CT Procedures in Madinah (Single Hospital), Saudi Arabia
This study aims to assess effective radiation doses (EDs) for pediatric computed tomography (CT) procedures in Madinah (single hospital), Saudi Arabia, and propose diagnostic reference levels (DRLs) for these procedures. This retrospective study collected data from 600 pediatric patients who underwent five CT procedures. The data were categorized by the type of CT procedure and the age of the patients. EDs and proposed DRLs for the pediatric CT procedures were computed. The highest EDs were found for abdominal (6.3 mSv) and head (4.8 mSv) CT procedures in pediatric patients aged vol and DLP for abdominal and head CT procedures in pediatric patients aged <1 year were 4.2 mGy, 94 mGy.cm and 25 mGy, 414 mGy.cm, respectively. Chest EDs had the lowest EDs among all pediatric CT procedures, with EDs of 1.93, 1.51, 1.91, and 2.05 mSv in patients aged <1, 1 ≤ to < 5, 5 ≤ to < 10, and 10 ≤ to ≤ 15 years, respectively. It can be concluded that optimization is required for abdominal and head CT procedures in pediatric patients aged <1 year. Frequent updates on ED and DRL calculations will help monitor radiation doses and minimize radiation risks for patients undergoing these procedures.
- 27 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7583
Open AccessAssessing Effective Doses and Proposing DRLs for Pediatric CT Procedures in Madinah (Single Hospital), Saudi Arabia
This study aims to assess effective radiation doses (EDs) for pediatric computed tomography (CT) procedures in Madinah (single hospital), Saudi Arabia, and propose diagnostic reference levels (DRLs) for these procedures. This retrospective study collected data from 600 pediatric patients who underwent five CT procedures. The data were categorized by the type of CT procedure and the age of the patients. EDs and proposed DRLs for the pediatric CT procedures were computed. The highest EDs were found for abdominal (6.3 mSv) and head (4.8 mSv) CT procedures in pediatric patients aged vol and DLP for abdominal and head CT procedures in pediatric patients aged <1 year were 4.2 mGy, 94 mGy.cm and 25 mGy, 414 mGy.cm, respectively. Chest EDs had the lowest EDs among all pediatric CT procedures, with EDs of 1.93, 1.51, 1.91, and 2.05 mSv in patients aged <1, 1 ≤ to < 5, 5 ≤ to < 10, and 10 ≤ to ≤ 15 years, respectively. It can be concluded that optimization is required for abdominal and head CT procedures in pediatric patients aged <1 year. Frequent updates on ED and DRL calculations will help monitor radiation doses and minimize radiation risks for patients undergoing these procedures.