Stéphane Tercier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Stéphane Tercier has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Frédéric Vauclair
Bone and Motion Center, Hirslanden Clinique Bois-Cerf, Lausanne, Switzerland
2 shared publications Aline Bregou-Bourgeois
Unité Pédiatrique de Chirurgie Orthopédique et Traumatologique (UPCOT), Lausanne University Hospital (CHUV), Site de l'hôpital de l'enfance, Avenue Montétan 16, 1007 Lausanne, Switzerland
1 shared publication- Aline Brégou-Bourgeois
Pediatric Orthopedic and Trauma Surgery Unit, Centre Hospitalier Universitaire Vaudois, Children's Hospital, Chemin de Montetan 16, CH-1000, Lausanne 7, Switzerland. address for S. Tercier:. address for A. Brégou-Bourgeois:. address for P.-Y. Zambelli:. address for F. Vauclair:
1 shared publication - Chantal Clément
Pediatric oncology and hematology unit, Centre hospitalier universitaire vaudois and University of Lausanne, Rue du Bugnon 46, CH-1011, Lausanne, Switzerland
1 shared publication - Christophe Gapany
Service of Paediatric Surgery, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
1 shared publication - Jean-Marc Joseph
Paediatric Surgery, Paediatric Department, University Hospital CHUV, CH-1011 Lausanne, Switzerland
1 shared publication
Latest Publications
- 17 July 2013
- Vol. 9 (393) , 1408-13
[Anterior cruciate ligament injuries in children].
An increasing number of anterior cruciate ligament injuries are now seen in children and girls seem to be equally affected. Such neglected or untreated lesions could be the cause of early degenerative changes. Recently, many authors support the trend toward early surgical management in skeletally immature patients with complex meniscal tear or recurrent knee instability after proper rehabilitation. Improvement in pediatric knowledge and surgical techniques tend to support a tendency for more surgical treatment in children. The type of management is choosing according to history and physical examination. Magnetic resonance imaging is a useful tool not only for diagnosis but also for surgical treatment planning. We usually recommend anterior cruciate ligament reconstruction in children with knee instability or with further damages to the joint.
- 17 July 2013
- Vol. 9 (393) , 1408-13
[Anterior cruciate ligament injuries in children].
An increasing number of anterior cruciate ligament injuries are now seen in children and girls seem to be equally affected. Such neglected or untreated lesions could be the cause of early degenerative changes. Recently, many authors support the trend toward early surgical management in skeletally immature patients with complex meniscal tear or recurrent knee instability after proper rehabilitation. Improvement in pediatric knowledge and surgical techniques tend to support a tendency for more surgical treatment in children. The type of management is choosing according to history and physical examination. Magnetic resonance imaging is a useful tool not only for diagnosis but also for surgical treatment planning. We usually recommend anterior cruciate ligament reconstruction in children with knee instability or with further damages to the joint.
- Open Access
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 869418
Lateral Condyle Fracture of the Humerus in Children Treated with Bioabsorbable Materials
The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow‐up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 869418
Open AccessLateral Condyle Fracture of the Humerus in Children Treated with Bioabsorbable Materials
The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow‐up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.
- 12 December 2012
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 2 (4) , e79
Posteriorly Displaced Fragment in a Juvenile Tillaux Fracture
- 12 December 2012
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 2 (4) , e79
Posteriorly Displaced Fragment in a Juvenile Tillaux Fracture
- Open Access
- 13 November 2008
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 2 (1) , 30
Incidents and complications of totally implanted vascular access devices in children: a prospective study
Background Totally implanted vascular access devices are frequently used in children for repeated blood samples or intravenous treatments. This prospective study aims at identifying the risk factors associated with infections, obstructions and surgical complications of these devices in pediatric patients. Methods From January 2006 to January 2008, all children older than one year of age with a diagnosis of solid or blood cell malignancy were included in the study. Insertion was performed by the surgeon according to a standardized protocol after landmark-guided puncture of the subclavian or internal jugular vein by a senior anesthesiologist. Dressing and post-operative care were standardized. Every manipulation was prospectively recorded by specialized dedicated nurses, and all patients were screened for complications one month post-surgery. Results 45 consecutive patients 1 to 16 years old were enrolled in the study. Mean age at the time of procedure was 8.5 years (range 1.3–15.6; SD ± 4.88). There were 12 peroperative adverse events in 45 procedures (27%), detailed as follows: 3 pneumothoraces (7%), 3 hematomas (7%), 6 arterial punctures (13%). Among these events, intervention was necessary for two pneumothorax and one arterial puncture. There was no air embolism. At one month, we recorded 5 post-operative complications (11%): 2 thrombotic obstructions, one unsightly scar, and one scapular pain of unknown etiology. One patient needed repositioning of the catheter. There was no catheter-related infection. Conclusion Prospective recording of TIVA insertion in children reveals a significant number of early incidents and complications, mainly associated with the percutaneous puncture technique. We found no infection in this series. Results of a longer follow-up in the same population are pending.
- 13 November 2008
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 2 (1) , 30
Open AccessIncidents and complications of totally implanted vascular access devices in children: a prospective study
Background Totally implanted vascular access devices are frequently used in children for repeated blood samples or intravenous treatments. This prospective study aims at identifying the risk factors associated with infections, obstructions and surgical complications of these devices in pediatric patients. Methods From January 2006 to January 2008, all children older than one year of age with a diagnosis of solid or blood cell malignancy were included in the study. Insertion was performed by the surgeon according to a standardized protocol after landmark-guided puncture of the subclavian or internal jugular vein by a senior anesthesiologist. Dressing and post-operative care were standardized. Every manipulation was prospectively recorded by specialized dedicated nurses, and all patients were screened for complications one month post-surgery. Results 45 consecutive patients 1 to 16 years old were enrolled in the study. Mean age at the time of procedure was 8.5 years (range 1.3–15.6; SD ± 4.88). There were 12 peroperative adverse events in 45 procedures (27%), detailed as follows: 3 pneumothoraces (7%), 3 hematomas (7%), 6 arterial punctures (13%). Among these events, intervention was necessary for two pneumothorax and one arterial puncture. There was no air embolism. At one month, we recorded 5 post-operative complications (11%): 2 thrombotic obstructions, one unsightly scar, and one scapular pain of unknown etiology. One patient needed repositioning of the catheter. There was no catheter-related infection. Conclusion Prospective recording of TIVA insertion in children reveals a significant number of early incidents and complications, mainly associated with the percutaneous puncture technique. We found no infection in this series. Results of a longer follow-up in the same population are pending.